Images are representations only.

SENSY Triple Output Pancake Cell, Capacity 50k lbs, 300% Breaking Load, IP66

Price
Request a Quote
Stock
Out of Stock
  • Load Cell Capacity: 50,000 lb
  • Breaking Load: 300%
  • Maximum Operating Load: 150%
  • Accuracy Class: 0.25%
  • Protection: IP66
  • Output Signal (sensitivity): 16 mA
  • Integrated Options:
    • Triple independent bridges
    • Bulk head mounted amplifier housing
    • B-Amph MS3102E-14S-6P no cable

  • Approvals:
    • CSA Intrinsically Safe, Entity for Hazardous Locations
    • Ex ia IIC T6 Ga
    • Ex ia IIIC T80oC Da
    • Class I, Division 1, Groups A,B,C and D; Class II, Division 1, Groups E,F,G Class III
    • US Standards
    • AEx ia IIC T6 Ga
    • AEx is IIIC T80oC Da
    • Class 1, Division 1, Groups A,B,C and D; Class II, Division1, Groups E,F,G Class III

  • Temperature Compensation: -40oC to 60oC
  • Load Cell Capacity: 50,000 lb
  • Breaking Load: 300%
  • Maximum Operating Load: 150%
  • Accuracy Class: 0.25%
  • Protection: IP66
  • Output Signal (sensitivity): 16 mA
  • Integrated Options:
    • Triple independent bridges
    • Bulk head mounted amplifier housing
    • B-Amph MS3102E-14S-6P no cable

  • Approvals:
    • CSA Intrinsically Safe, Entity for Hazardous Locations
    • Ex ia IIC T6 Ga
    • Ex ia IIIC T80oC Da
    • Class I, Division 1, Groups A,B,C and D; Class II, Division 1, Groups E,F,G Class III
    • US Standards
    • AEx ia IIC T6 Ga
    • AEx is IIIC T80oC Da
    • Class 1, Division 1, Groups A,B,C and D; Class II, Division1, Groups E,F,G Class III

  • Temperature Compensation: -40oC to 60oC

Specifications

Accuracy

  • 1,000 D

Approvals & Certifications

  • CE
  • CSA
  • IECEx
  • Intrinsic Safety Ex II 1 GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da

Cable Length

  • 10 to 39 feet (3 to 12 metres)

Communication

  • RS-232C, RS-485

Enclosure, Body Material

  • Alloy Steel (2965)
  • Aluminum (2962)
  • Stainless Steel (2960)

Environmental Protection

  • IP66

Excitation Voltage

  • 10 Vdc

Insulation Resistance

  • > 5,000 megaohms

Linearity

  • Linearity Error: < ± 0.10 % (Class 0.1) to < ± 0.25 % (Class 0.25) of Full Scale

Load Limit

  • 150 % of Full Scale

Operating Temperature

  • Optional High Service Temperature: 180° C (356° F)

Repeatability

  • Repeatability Error: < ± 0.03 % (Class 0.25) < ± 0.1 % (Class 0.1) of Full Scale

Resistance

  • Input/Output: 702 ± 2 ohms

Sensitivity

  • < ± 0.3 %
  • 2 mV/V

Service Temperature

  • -30° to 70° C (-22° to 158° F)

Static Lateral Force

  • 50 % of Full Scale

Storage Temperature

  • -50° to 85° C (-58° to 185° F)

Temperature Coefficient

  • < ± 0.035 % of Full Scale/10° C (18° F)
  • < ± 0.05 % of Full Scale/10° C (18° F)

Zero Balance

  • ± 0.02 mV/V