Images are representations only.

KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 2" NPT, 36"U, SST, Lens, CSA

Price
Request a Quote
Stock
In Stock 2 - 5 days
  • Process Connections: 2" MNPT
  • Insertion 'U' Length: Custom 36"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges:
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)

  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X

Crate Required

    • Process Connections: 2" MNPT
    • Insertion 'U' Length: Custom 36"
    • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
    • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
    • Temperature Ranges:
      • Sensor: -55°C to 200°C (-58°F to 392°F)
      • Electronics: -55°C to 65°C (-67°F to 149°F)

    • Local Enclosure: Aluminum Flameproof, 1" FNPT
    • Cover: Flameproof Glass Lens Cover
    • Remote Electronics Enclosure and Cover: Not Required
    • Wetted Materials:
      • Standard: 316 Stainless Steel

    • Outputs/Communications:
      • Two Independent Relays (SPDT)
      • 4-20 mA (Thermal Signal, Scalable)
      • Modbus Communication via RS-485
      • RCMS (Remote Control & Monitoring Software) Downloadable from

    • Electronics - Standard Features:
      • Automated Redundant Self-Test Diagnostics
      • Display Panel Lock-Out
      • Easy Set-up:
        • No Mechanical Jumpers or Trim Pots
        • Intelligent Push Button Interface
        • Constant Display of Operation (Flow/Level)

      • Start-Up Bypass Timer

    • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X

    Crate Required

      Specifications

      Accuracy

      • Flow Service: ± 1.0 % of Set Point Velocity over Operating Range of ± 28° C (± 50° F)
      • Level Service: ± 0.64 cm (0.25”)

      Applications

      • Flow
      • Interface
      • Level

      Approvals & Certifications

      • CRN - 316, 316L Stainless Steel - Canadian Registration Number 0F20731.5C: 2053 psi, 14,155 kPa, 142 bar
      • CSA - Local (Sensor) Enclosure Flameproof: Class I, Div. 1, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Group IIB + H₂) Temperature Code: T3 Enclosure Typical 4, IP55 Single Seal Approved Per ANSI/ISA 12.27.01-2003
      • CSA - Remote Electronics Enclosure - Optional Flameproof: Class I, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Groups IIB + H₂) Temperature Code: T3
      • FM - Local (Sensor) Enclosure Flameproof: Class I, Div. 1, Groups B, C, D Temperature Codes: T2D (Ta=75° C), T3 (Ta=65° C) Class I, Zone 1, AEx d IIB + H₂ Enclosure Typical 4/IP55
      • FM - Remote Electronics Enclosure - Optional Flameproof: Class I, Div. 1, Groups B, C, D Temperature Codes: T2D (Ta=75° C), T3 (Ta=65° C) Class I, Zone 1, AEx d IIB + H₂ Enclosure Typical 4/IP55

      Communication

      • Modbus RTU Communication-Alarms, Flow Status & Diagnostics
      • RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software

      Cover - for Local Enclosure

      • Blind Cover - Flameproof
      • Glass Lens Cover - Flameproof

      Electronics - Standard Features

      • *Configurable only from the Kayden RCM Software
      • 100 % Digital Design. Electronics are Environmentally Sealed
      • 4-Adjustable Independent Switch Point Timers
      • Automated Redundant Self-Test Diagnostics
      • Display Panel Lock-Out*
      • Easy Setup: No Mechanical Jumpers or Trim Pots
      • Incrementally Adjustable Heater Power (5 % Steps) with Automatic Over-Range Protection
      • Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
      • Start-Up Bypass Timer
      • Temperature Compensation
      • Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode

      Enclosure Finish

      • Powder-Coated Polyester TGIC

      Enclosure, Body Details

      • 1” NPT Female Conduit Connection
      • Buna-N O-Ring on Cover

      Enclosure, Body Material

      • Copper-Free Aluminum (Does Not Exceed 0.4 % Copper)

      Environmental Protection

      • IP55
      • IP67
      • NEMA 4X

      Input Power

      • 12-24 Vdc, 120-240 Vac, 50/60 Hz
      • Power Consumption: Max.
      • Universal Power Input

      Insertion 'U' Length

      • 1.2” (3 cm)
      • 12” (30 cm)
      • 18” (46 cm)
      • 2” (5 cm)
      • 3” (7.5 cm)
      • 4” (10.1 cm)
      • 6” (15.2 cm)
      • 9” (23 cm)
      • Custom 'U' Lengths 2.5” to 120” (6.4 cm to 305 cm) Available in 1/2” (1.0 cm) Increments.

      NPT Connection

      • 1” NPT Male
      • 1/2” NPT Male
      • 1-1/2” NPT Male
      • 1-1/4” NPT Male
      • 2” NPT Male
      • 3/4” NPT Male

      Operating Pressure - Sensor

      • CRN - All Process Connections - 316/316 Stainless Steel - Canadian Registration Number 0F20731.5C: Max.
      • CRN - All Process Connections - Hastelloy C-276 - Canadian Registration Number 0F20731.5C: Max.
      • CRN - All Process Connections - Titanium - Canadian Registration Number 0F20731.5C: Max.
      • CSA - All Process Connections: Max.

      Operating Temperature - Electronics

      • -55° to 65° C (-67° to 149° F)

      Operating Temperature - Sensor

      • -55° to 200° C, (-67° to 392° F)

      Output

      • 4-20 mA (Thermal Signal, Scaleable) 120 Vac, Max.

      Principle of Operation

      • Thermal, Calorimetric

      Remote Control & Monitoring Software

      • Adjust Relay Modes
      • Adjust Set Points 1 & 2
      • Load or Save User Settings
      • Lock or Unlock the Display Panel to Protect the Settings
      • Many Other Adjustable Features
      • Modify Heater Settings to Optimize Response Time
      • Monitor Operating Status
      • Operated Via a Personal Computer Locally or from a Remote Control Center
      • Visualize the Actions of the Process Via the Graphical Display

      Remote Electronics Enclosure & Cover

      • Blind Cover - Flameproof
      • Glass Lens Cover - Flameproof

      Response Time

      • Approximately 0.5 to 30 seconds

      Sensor, Probe Style

      • Insertion

      Storage Temperature

      • Product Should be Stored in a Clean & Dry Environment between -30° & 60° C (-22° & 140° F)

      Switch Point Range

      • Gases: 0.25 to 200 sfps, 0.08 to 60 SMPS - Standard Condition 21° C (70° F) at 14.7 psi (1 Atm)
      • Hydrocarbon-based Liquids: 0.01 to 5.0 FPS, 0.003 to 1.50 MPS
      • Water-based Liquids: 0.01 to 3.00 FPS, 0.003 to 0.9 MPS

      Switch Type

      • SPDT Sealed Relay Contacts Rated @ 4 Amps Resistive 230 Vac or 30 Vdc, Max.

      Wetted Materials

      • 316, 316L Stainless Steel
      • All-Welded Construction
      • Hastelloy C-276
      • Titanium

      Documentation

      Outline Drawings

      Similar SKUs

      810-RAD-I0360-C1G0A-1E
      810-RAD-I0360-C1G0A-1E
      Kayden CLASSIC 810 Flow, Level, Interface Switch & Transmitter
      Kayden Instruments
      $2,656.96USD
      Out of Stock
      KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 36"U, SST, Lens, CSA
      810-RAH-0060-C1G0A-1E
      810-RAH-0060-C1G0A-1E
      Kayden CLASSIC 810 Flow, Level, Interface Switch & Transmitter
      Kayden Instruments
      $1,743.70USD
      Out of Stock
      KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 2" NPT, 6"U, SST, Lens, CSA
      810-RAH-0180-C1G0A-1E
      810-RAH-0180-C1G0A-1E
      Kayden CLASSIC 810 Flow, Level, Interface Switch & Transmitter
      Kayden Instruments
      $2,149.60USD
      Out of Stock
      KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 2" NPT, 18"U, SST, Lens, CSA
      810-RAH-I0240-C1G0A-1E
      810-RAH-I0240-C1G0A-1E
      Kayden CLASSIC 810 Flow, Level, Interface Switch & Transmitter
      Kayden Instruments
      Request a Quote
      Out of Stock
      KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 2" NPT, 24"U, SST, Lens, CSA
      810-RAH-0120-C1G0A-1E
      810-RAH-0120-C1G0A-1E
      Kayden CLASSIC 810 Flow, Level, Interface Switch & Transmitter
      Kayden Instruments
      $1,946.65USD
      Out of Stock
      KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 2" NPT, 12"U, SST, Lens, CSA
      810-RAG-I0360-C1B1G-1E
      810-RAG-I0360-C1B1G-1E
      Kayden CLASSIC 810 Flow, Level, Interface Switch & Transmitter
      Kayden Instruments
      Request a Quote
      Out of Stock
      KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1-1/2" NPT, 36"U, SST, Remote,Lens,CSA
      810-RAH-0040-C1G0A-1E
      810-RAH-0040-C1G0A-1E
      Kayden CLASSIC 810 Flow, Level, Interface Switch & Transmitter
      Kayden Instruments
      $1,675.81USD
      Out of Stock
      KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 2" NPT, 4"U, SST, Lens, CSA
      810-RAE-I0360-C1B0A-9E
      810-RAE-I0360-C1B0A-9E
      Kayden CLASSIC 810 Flow, Level, Interface Switch & Transmitter
      Kayden Instruments
      $2,487.59USD
      Out of Stock
      KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 36"U, SST, Blind, FM