Images are representations only.
816-RAET-0060-C1B1G-1E
KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, P/G, 1" NPT, 6"U, SST, Remote, Lens,CSA
Price
Request a Quote
Stock
In Stock
3 - 5 days
- 816-R: Threaded Retractable Packing Gland (1" MNPT)
- A: Sensor Material: 316/316L Stainless Steel
- E: Process Connection - Male NPT: 1"
- T: Retraction Assembly: Low Pressure, 316/316L Stainless Steel (MWP 50 psi)
- 0060: Insertion 'U' Length: 6", 15.2 cm
- C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
- 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
- B: Cover for Local Enclosure: Flameproof Blind Cover
- 1G: Remote Electronics Enclosure & Cover: Flameproof Glass Lens Cover
- 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
- E: Language: English
- Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software) Downloadable from
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
Description
- 816-R: Threaded Retractable Packing Gland (1" MNPT)
- A: Sensor Material: 316/316L Stainless Steel
- E: Process Connection - Male NPT: 1"
- T: Retraction Assembly: Low Pressure, 316/316L Stainless Steel (MWP 50 psi)
- 0060: Insertion 'U' Length: 6", 15.2 cm
- C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
- 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
- B: Cover for Local Enclosure: Flameproof Blind Cover
- 1G: Remote Electronics Enclosure & Cover: Flameproof Glass Lens Cover
- 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4
- E: Language: English
- Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software) Downloadable from
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
Product Series Specifications
Specifications
Brand
Accuracy
- Flow Service: ± 1.0 % of Set Point Velocity over Operating Range of ± 28° C (± 50° F)
- Level Service: ± 0.64 cm (0.25”)
Applications
- Flow
- Interface
- Level
Approvals & Certifications
- CRN - Canadian Registration Number - the Kayden Classic 816 does not have a CRN Number
- CSA
- CSA - Local (Sensor) Enclosure Flameproof: Class I, Div. 1, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Group IIB + H₂) Temperature Code: T3 Enclosure Typical 4, IP55 Single Seal Approved Per ANSI/ISA 12.27.01-2003
- CSA - Remote Electronics Enclosure - Optional Flameproof: Class I, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Groups IIB + H₂) Temperature Code: T3
- FM
- FM - Local (Sensor) Enclosure Flameproof: Class I, Div. 1, Groups B, C, D Temperature Codes: T2D (Ta=75° C), T3 (Ta=65° C) Class I, Zone 1, AEx d IIB + H₂ Enclosure Typical 4/IP55
- FM - Remote Electronics Enclosure - Optional Flameproof: Class I, Div. 1, Groups B, C, D Temperature Codes: T2D (Ta=75° C), T3 (Ta=65° C) Class I, Zone 1, AEx d IIB + H₂ Enclosure Typical 4/IP55
Communication
- Modbus RTU Communication-Alarms, Flow Status & Diagnostics
- RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software
Cover - for Local Enclosure
- Blind Cover - Flameproof
- Glass Lens Cover - Flameproof
Electronics - Standard Features
- *Configurable only from the Kayden RCM Software
- 100 % Digital Design. Electronics are Environmentally Sealed
- 4-Adjustable Independent Switch Point Timers
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out*
- Easy Setup: No Mechanical Jumpers or Trim Pots
- Incrementally Adjustable Heater Power (5 % Steps) with Automatic Over-Range Protection
- Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
- Start-Up Bypass Timer
- Temperature Compensation
- Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode
Enclosure Finish
- Powder-Coated Polyester TGIC
Enclosure, Body Details
- 1” NPT Female Conduit Connection
- Buna-N O-Ring on Cover
Enclosure, Body Material
- Copper-Free Aluminum (Does Not Exceed 0.4 % Copper)
Environmental Protection
- IP55
- NEMA 4 / IP55
Input Power
- 12-24 Vdc, 115-230 Vac, 50/60 Hz / Universal Power Input
- Power Consumption: Max.
Insertion 'U' Length
- Custom 'U' Lengths 2.5” to 120” (6.4 cm to 305 cm) Available in 1/2” (1.0 cm) Increments.
NPT Connection
- 1” NPT Male
Operating Pressure - Sensor
- Threaded Style: Max.
Operating Temperature - Electronics
- -55° to 65° C (-67° to 149° F)
Operating Temperature - Sensor
- -45° to 200° C (-50° to 392° F)
Output
- 4-20 mA (Thermal Signal, Scaleable)
Principle of Operation
- Thermal, Calorimetric
Process Connection Style
- Threaded Retractable
Remote Control & Monitoring Software
- Adjust Relay Modes
- Adjust Set Points 1 & 2
- Load or Save User Settings
- Lock or Unlock the Display Panel to Protect the Settings
- Many Other Adjustable Features
- Modify Heater Settings to Optimize Response Time
- Monitor Operating Status
- Operated Via a Personal Computer Locally or from a Remote Control Center
- Visualize the Actions of the Process Via the Graphical Display
Remote Electronics Enclosure & Cover
- Blind Cover - Flameproof
- Glass Lens Cover - Flameproof
Response Time
- Approximately 0.5 to 30 seconds
Retraction Assembly
- Low Pressure with Security Chain, 316, 316L Stainless Steel (MWP 125 psi)
- Low Pressure: 316, 316L Stainless Steel (MWP 50 psi)
- Medium Pressure: 316, 316L Stainless Steel (MWP 500 psi)
Sensor, Probe Style
- Insertion
Storage Temperature
- Product Should be Stored in a Clean & Dry Environment between -30° & 60° C (-22° & 140° F)
Switch Point Range
- Gases: 0.25 to 200 sfps, 0.08 to 60 SMPS - Standard Condition 21° C (70° F) at 14.7 psi (1 Atm)
- Hydrocarbon-based Liquids: 0.01 to 5.0 FPS, 0.003 to 1.50 MPS
- Water-based Liquids: 0.01 to 3.00 FPS, 0.003 to 0.9 MPS
Switch Type
- 2 SPDT Sealed Relay Contacts Rated @ 4 Amps Resistive 230 Vac or 30 Vdc, Max.
Wetted Materials
- 316, 316L Stainless Steel
- All-Welded Construction
- Hastelloy C-276
- Other Metals Available
- Titanium Grade 2
Product Series Documentation
Documentation
Data Sheets
Product Manuals
Application Considerations
Application Notes
- Application Note - Kayden 4-20mA Analog Output (pdf) (766 KB)
- Application Note - Kayden Acid Level Detection (pdf) (1.4 MB)
- Application Note - Kayden Fail Safe (pdf) (894 KB)
- Application Note - Kayden High Level Detection Holding Tank (pdf) (996 KB)
- Application Note - Kayden Monitoring Digester Flow (pdf) (831 KB)
- Application Note - Kayden Oil Water Separation (pdf) (1.2 MB)
- Application Note - Kayden Pulp and Paper Digester Tank (pdf) (1.1 MB)
- Application Note - Kayden Pulp and Paper Skimmer Tank (pdf) (829 KB)
- Application Note - Kayden Pump Monitoring and Protection (pdf) (1.0 MB)
- Application Note - Kayden Pump Monitoring and Protection Remote (pdf) (1.2 MB)
Catalogs
Certifications & Approvals
Document
Outline Drawings
- Outline Dimension Drawing - Kayden CLASSIC 816 Local Enclosure Low Pressure (pdf) (390 KB)
- Outline Dimension Drawing - Kayden CLASSIC 816 Local Enclosure Low Pressure w/Chain (pdf) (602 KB)
- Outline Dimension Drawing - Kayden CLASSIC 816 Local Enclosure Medium Pressure (pdf) (635 KB)
- Outline Dimension Drawing - Kayden CLASSIC 816 Remote Enclosure Low Pressure (pdf) (794 KB)
- Outline Dimension Drawing - Kayden CLASSIC 816 Remote Enclosure Low Pressure w/Chain (pdf) (1,004 KB)
- Outline Dimension Drawing - Kayden CLASSIC 816 Remote Enclosure Medium Pressure (pdf) (1.0 MB)
Software
Similar SKUs

816-RAEX-0060-C1B1G-1E
Kayden CLASSIC 816 Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
Out of Stock
KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, P/G, 1" NPT, 6"U, SST, Remote, Lens,CSA

816-RAET-0060-C1B1B-1E
Kayden CLASSIC 816 Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
Out of Stock
KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, P/G, 1" NPT, 6"U, SST, Remote, Blind,CSA

816-RAEJ-0060-C1B1G-1E
Kayden CLASSIC 816 Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
Out of Stock
KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, P/G, 1" NPT, 6"U, SST, Remote, Lens,CSA

816-RAET-I0480-C1B1G-1E
Kayden CLASSIC 816 Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
Out of Stock
KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, P/G, 1" NPT, 48"U, SST, Remote, Lens,CSA

816-RAET-0480-C1B1G-1E
Kayden CLASSIC 816 Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
Out of Stock
KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, P/G, 1" NPT, 48"U, SST, Remote, Lens,CSA

816-RAET-I0150-C1B1G-1E
Kayden CLASSIC 816 Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
Out of Stock
KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, P/G, 1" NPT, 15"U, SST, Remote, Lens,CSA

816-RAET-0180-C1B1G-1E
Kayden CLASSIC 816 Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
Out of Stock
KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, P/G, 1" NPT, 18"U, SST, Remote, Lens,CSA

816-RAET-0360-C1B1G-1E
Kayden CLASSIC 816 Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
Out of Stock
KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, P/G, 1" NPT, 36"U, SST, Remote, Lens,CSA