Images are representations only.

832-RA3A-141A-I0090-AV0C-1G0A9E

Series: Kayden CLASSIC 832 Thermal Flow Switch & Transmitter Brand: Kayden Instruments

KAYDEN® CLASSIC® Thermal Flow & Level Switch, Modbus, In-Line, 1-1/2" 150# RF High-Hub SST Flange, a Length (Face-to-Face) = 9", 316 SST Sensor with Nickel Braze, Local Electronics Enclosure with Glass Lens Cover, Approvals: FM

Price
$2,008.67USD
Stock
In Stock 5 - 10 days
  • Process Connection: Flanged Raised Face, 2" 150# Vertical
  • Adjustable Set Point Range: 0-20,000 cc/s
  • Sensor Assembly Body Length: 9", 22.8cm
  • Process Connection: 3/4" MNPT
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -50°F to 392°F
  • Local Enclosure: Aluminum Flameproof, 1" FNPT Conduit Connection
  • Cover: Flameproof Glass Lens
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • 316 Stainless Steel with Nickel Braze

  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus

  • FM, NACE, NEMA 4
  • Process Connection: Flanged Raised Face, 2" 150# Vertical
  • Adjustable Set Point Range: 0-20,000 cc/s
  • Sensor Assembly Body Length: 9", 22.8cm
  • Process Connection: 3/4" MNPT
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -50°F to 392°F
  • Local Enclosure: Aluminum Flameproof, 1" FNPT Conduit Connection
  • Cover: Flameproof Glass Lens
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • 316 Stainless Steel with Nickel Braze

  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus

  • FM, NACE, NEMA 4

Specifications

Accuracy

  • Flow Service: ± 1.0 % of Set Point Velocity over Operating Range of ± 28° C (± 50° F)
  • Level Service: ± 0.64 cm (0.25”)

Applications

  • Flow

Approvals & Certifications

  • CSA
  • CSA - Local (Sensor) Enclosure Flameproof: Class I, Div. 1, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Group IIB + H₂) Temperature Code: T3 Enclosure Typical 4, IP55 Single Seal Approved Per ANSI/ISA 12.27.01-2003
  • CSA - Remote Electronics Enclosure - Optional Flameproof: Class I, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Groups IIB + H₂) Temperature Code: T3
  • FM
  • FM - Local (Sensor) Enclosure Flameproof: Class I, Div. 1, Groups B, C, D Temperature Codes: T2D (Ta=75° C), T3 (Ta=65° C) Class I, Zone 1, AEx d IIB + H₂ Enclosure Typical 4/IP55
  • FM - Remote Electronics Enclosure - Optional Flameproof: Class I, Div. 1, Groups B, C, D Temperature Codes: T2D (Ta=75° C), T3 (Ta=65° C) Class I, Zone 1, AEx d IIB + H₂ Enclosure Typical 4/IP55

Bleed Port

  • 1/4” Threaded

Communication

  • Modbus RTU Communication-Alarms, Flow Status & Diagnostics
  • RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software

Cover - for Local Enclosure

  • Blind Cover - Flameproof
  • Glass Lens Cover - Flameproof

Electronics - Standard Features

  • *Configurable only from the Kayden RCM Software
  • 100 % Digital Design. Electronics are Environmentally Sealed
  • 4-Adjustable Independent Switch Point Timers
  • Automated Redundant Self-Test Diagnostics
  • Display Panel Lock-Out*
  • Easy Setup: No Mechanical Jumpers or Trim Pots
  • Incrementally Adjustable Heater Power (5 % Steps) with Automatic Over-Range Protection
  • Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
  • Start-Up Bypass Timer
  • Temperature Compensation
  • Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode

Enclosure Finish

  • Powder-Coated Polyester TGIC

Enclosure, Body Details

  • 1” NPT Female Conduit Connection
  • Buna-N O-Ring on Cover

Enclosure, Body Material

  • Copper-Free Aluminum (Does Not Exceed 0.4 % Copper)

Environmental Protection

  • IP55
  • IP67
  • NEMA 4X
  • TYPE 4

Flange Material

  • 316, 316L Stainless Steel

Flange Size - 1” (DN 25)

  • 1” (DN 25) - 150#
  • 1” (DN 25) - 1500#
  • 1” (DN 25) - 300#
  • 1” (DN 25) - 600#
  • 1” (DN 25) - 900#

Flange Size - 10” (DN 250)

  • 10” (DN 250) - 150#
  • 10” (DN 250) - 1500#
  • 10” (DN 250) - 300#
  • 10” (DN 250) - 600#
  • 10” (DN 250) - 900#

Flange Size - 1-1/2” (DN 40)

  • 1-1/2” (DN 40) - 150#
  • 1-1/2” (DN 40) - 1500#
  • 1-1/2” (DN 40) - 300#
  • 1-1/2” (DN 40) - 600#
  • 1-1/2” (DN 40) - 900#

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150#
  • 2” (DN 50) - 1500#
  • 2” (DN 50) - 300#
  • 2” (DN 50) - 600#
  • 2” (DN 50) - 900#

Flange Size - 3/4” (DN 20)

  • 3/4” (DN 20) - 150#
  • 3/4” (DN 20) - 1500#
  • 3/4” (DN 20) - 300#
  • 3/4” (DN 20) - 600#
  • 3/4” (DN 20) - 900#

Flange Size - 3” (DN 80)

  • 3” (DN 80) - 150#
  • 3” (DN 80) - 1500#
  • 3” (DN 80) - 300#
  • 3” (DN 80) - 600#
  • 3” (DN 80) - 900#

Flange Size - 4” (DN 100)

  • 4” (DN 100) - 150#
  • 4” (DN 100) - 1500#
  • 4” (DN 100) - 300#
  • 4” (DN 100) - 600#
  • 4” (DN 100) - 900#

Flange Size - 5” (DN 125)

  • 5” (DN 125) - 150#
  • 5” (DN 125) - 1500#
  • 5” (DN 125) - 300#
  • 5” (DN 125) - 600#
  • 5” (DN 125) - 900#

Flange Size - 6” (DN 150)

  • 6” (DN 150) - 150#
  • 6” (DN 150) - 1500#
  • 6” (DN 150) - 300#
  • 6” (DN 150) - 600#
  • 6” (DN 150) - 900#

Flange Size - 8” (DN 200)

  • 8” (DN 200) - 150#
  • 8” (DN 200) - 1500#
  • 8” (DN 200) - 300#
  • 8” (DN 200) - 600#
  • 8” (DN 200) - 900#

Flange Type

  • Raised Face (RF)
  • RTJ - Ring Typical Joint

Input Power

  • 12-24 Vdc, 115-230 Vac, 50/60 Hz / Universal Power Input
  • Power Consumption: Max.

Operating Pressure - Sensor

  • Maximum

Operating Temperature - Electronics

  • -55° to 65° C (-67° to 149° F)

Operating Temperature - Sensor

  • -45° to 200° C (-50° to 392° F)

Output

  • 4-20 mA (Thermal Signal, Scaleable)

Pipe Schedule

  • Schedule 40
  • Schedule 80

Principle of Operation

  • Thermal, Calorimetric

Remote Control & Monitoring Software

  • Adjust Relay Modes
  • Adjust Set Points 1 & 2
  • Load or Save User Settings
  • Lock or Unlock the Display Panel to Protect the Settings
  • Many Other Adjustable Features
  • Modify Heater Settings to Optimize Response Time
  • Monitor Operating Status
  • Operated Via a Personal Computer Locally or from a Remote Control Center
  • Visualize the Actions of the Process Via the Graphical Display

Remote Electronics Enclosure & Cover

  • Blind Cover - Flameproof
  • Glass Lens Cover - Flameproof

Response Time

  • Approximately 0.5 to 30 seconds

Sensor Assembly Body Lengths

  • Custom Body Lengths: 7” to 72” (18 cm to 182 cm) in 1/2” (1 cm) Increments

Sensor Orientation

  • Horizontal
  • Vertical

Sensor, Probe Style

  • InLine

Storage Temperature

  • Product Should be Stored in a Clean & Dry Environment between -30° & 60° C (-22° & 140° F)

Switch Point Range

  • Gases: 0.6 to 20,000 cc/second, Standard Condition: 21° C (70° F) at 14.7 psi (1 Atm)
  • Hydrocarbon-based Liquids: 0.033 to 110 cc/second
  • Water-based Liquids: 0.015 to 50 cc/second

Switch Type

  • 2 SPDT Sealed Relay Contacts Rated @ 4 Amps Resistive 230 Vac or 30 Vdc, Max.

Wetted Materials

  • 316, 316L Stainless Steel with Nickel Brazing

Documentation

Similar SKUs

812-RAA-141A-I0090-C1B1G-3E
812-RAA-141A-I0090-C1B1G-3E
Kayden CLASSIC 812 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
$2,957.42USD
In Stock 3 - 7 days
KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, 2" 150# RF SST, 9"U, RemoteLens, CSA/CRN
812-RAA-142A-I0090-C1G0A-1E
812-RAA-142A-I0090-C1G0A-1E
Kayden CLASSIC 812 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
In Stock 3 - 7 days
KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, 2" 300# RF SST, 9"U, Lens, CSA
812-RAA-142A-I0090-C1G0A-9E
812-RAA-142A-I0090-C1G0A-9E
Kayden CLASSIC 812 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
$2,348.14USD
In Stock 3 - 7 days
KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, 2" 300# RF SST, 9"U, Lens, FM
P02-RAD-0020-M-CRN
P02-RAD-0020-M-CRN
Kayden CLASSIC 810 Spare Sensor, 1/2" thru 2" MNPT, P02 Series
Kayden Instruments
$307.60USD
1 In Stock
KAYDEN® CLASSIC® 810 Series Thermal Flow, Level, Interface Sensor, 3/4" NPT, 2"U Length, 316 SST Sensor, Approvals: C CSA Us (UL Standards), CRN
810-RAD-0020-C1B1G-9E
810-RAD-0020-C1B1G-9E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
$1,756.66USD
3 - 5 days
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 2"U, SST, Remote, Lens, FM
810-RAE-I0015-C1G0A-3E
810-RAE-I0015-C1G0A-3E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
$1,241.52USD
2 - 4 weeks
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 1.5"U, SST, Lens, CRN/CSA
810-RAE-M0240-C1G0A-3E
810-RAE-M0240-C1G0A-3E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
$1,537.26USD
2 - 4 weeks
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 24 cm U, SST, Lens, CSA/CRN
810-RAE-M2890-C1G0A-3E
810-RAE-M2890-C1G0A-3E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
$4,287.14USD
2 - 4 weeks
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 289 cm U, SST, Lens, CSA/CRN