Images are representations only.

SENSY Tensiometer on Cable Load Cell, Capacity 15t, 300% Breaking Load, IP67, 6m Cable, ATEX

Price
Request a Quote
Stock
8 - 11 weeks
  • Capacity: 25,000 Lbs
  • Breaking Load: 300%
  • Maximum Operating Load: 150%
  • Nominal Temperature Range: -10° to +45°C
  • Operating Temperature: -30° to +70°C
  • Storage Temperature: -50° to +85°C
  • Compensated Temperature -40° to +40°C
  • Accuracy Class: SL
  • Material of Construction: Stainless Steel
  • Cable Length: 0m
  • Output Signal (Sensitivity): 16 mA
  • Connector MS3102E-14S-2P Amphenol
  • CSA Class I, Div I, Groups A,B,C & D
  • Protection: IP67
  • Capacity: 25,000 Lbs
  • Breaking Load: 300%
  • Maximum Operating Load: 150%
  • Nominal Temperature Range: -10° to +45°C
  • Operating Temperature: -30° to +70°C
  • Storage Temperature: -50° to +85°C
  • Compensated Temperature -40° to +40°C
  • Accuracy Class: SL
  • Material of Construction: Stainless Steel
  • Cable Length: 0m
  • Output Signal (Sensitivity): 16 mA
  • Connector MS3102E-14S-2P Amphenol
  • CSA Class I, Div I, Groups A,B,C & D
  • Protection: IP67

Specifications

Applications

  • Hookload Sensor for Drilling & Mud-logging
  • Tension Measurement for Suspended Bridges & Foot-bridges, Big Tops
  • Tension Measurement of Cable, Rope, Shrouds & Riggings of Electric Pylons, Transmission Antenna's, Towers, Flare Masts, barge Mooring Lines

Approvals & Certifications

  • ATEX Intrinsic Safety Ex II 1 GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
  • CE
  • CSA
  • IECEx

Cable Length

  • 19.69 feet (6 metres)

Capacity

  • 1 to 80 T

Communication

  • RS-232C, RS-485
  • USB

Electrical Connectors

  • DIN 45322

Enclosure, Body Material

  • Alloy Steel
  • Stainless Steel

Environmental Protection

  • IP67
  • IP68

Excitation Voltage

  • 10 Vdc
  • 3-12 Vdc - Nominal Range

Insulation Resistance

  • > 5,000 megaohms

Load

  • Breaking Load: > 300 % of Full Scale
  • Permissible Dynamic Loading: 70 % of Full Scale

Load Limit

  • 200 % of Full Scale

Resistance

  • Input/Output: 352 ± 2 ohms

Sensitivity

  • Nominal Sensitivity: ± 1 mV/V

Service Temperature

  • -30° to 70° C (-22° to 158° F)

Storage Temperature

  • -50° to 85° C (-58° to 185° F)

Temperature Coefficient

  • < ± 0.1 % of Full Scale/10° C (18° F)