Images are representations only.

KAYDEN CLASSIC Thermal Flow, Level,Interface Switch, Modbus, 2" 150# RF SST, 30cmU,Lens,CSA/CRN

Price
Request a Quote
Stock
In Stock 3 - 7 days
  • Process Connection:


  • 316 Stainless Steel Flanged
  • Raised Face 2"
  • ANSI: 150

[/li]
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s

  • Insertion 'U' Length: 30cm

  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz

  • Operating Pressure (Maximum): Per Flange Rating, ASME B16.5

  • Temperature Range (Sensor): -45°C to 200°C, -50°F to 392°F

  • Local Enclosure: Aluminum Flameproof, 1" FNPT

  • Cover: Flameproof Glass Cover

  • Remote Electronics Enclosure and Cover: Not Required

  • Wetted Materials:
    • Standard: 316 Stainless Steel


  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus


  • UL, CSA, CRN, Single Seal, NACE, NEMA 4

    • Process Connection:


    • 316 Stainless Steel Flanged
    • Raised Face 2"
    • ANSI: 150

    [/li]
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s

  • Insertion 'U' Length: 30cm

  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz

  • Operating Pressure (Maximum): Per Flange Rating, ASME B16.5

  • Temperature Range (Sensor): -45°C to 200°C, -50°F to 392°F

  • Local Enclosure: Aluminum Flameproof, 1" FNPT

  • Cover: Flameproof Glass Cover

  • Remote Electronics Enclosure and Cover: Not Required

  • Wetted Materials:
    • Standard: 316 Stainless Steel


  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus


  • UL, CSA, CRN, Single Seal, NACE, NEMA 4

  • Specifications

    Accuracy

    • Flow Service: ± 1.0 % of Set Point Velocity over Operating Range of ± 28° C ( ± 50° F)
    • Level Service: ± 0.64 cm (0.25”)

    Applications

    • Flow
    • Interface
    • Level

    Approvals & Certifications

    • CRN
    • CRN - Canadian Registration Numbers - 1” & 1-1/2” - Flanges Approved for All Provinces & Territories 812-RAA Series: CRN # 0F13787.2C 316, 316L Stainless Steel, Pipe NPS 1/2” Schedule 80 Code of Construction: ASME B31.3, Maximum
    • CRN - Canadian Registration Numbers - 2” through 10” Flanges - Approved for All Provinces & Territories 812-RAA Series: CRN # 0F13773.2C 316, 316L Stainless Steel, Pipe NPS 3/4” Schedule 80 Code of Construction: ASME B31.3, Maximum
    • CSA
    • CSA - Local (Sensor) Enclosure Flameproof: Class I, Division 1, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Group IIB + H₂) Temperature Code: T3 Enclosure Typical 4, IP55 Single Seal Approved Per ANSI/ISA 12.27.01-2003
    • CSA - Remote Electronics Enclosure - Optional Flameproof: Class I, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Groups IIB + H₂) Temperature Code: T3
    • FM
    • FM - Local (Sensor) Enclosure Flameproof: Class I, Division 1, Groups B, C, D Temperature Codes: T2D (Ta=75° C), T3 (Ta=65° C) Class I, Zone 1, AEx d IIB + H₂ Enclosure Typical 4/IP55
    • FM - Remote Electronics Enclosure - Optional Flameproof: Class I, Division 1, Groups B, C, D Temperature Codes: T2D (Ta=75° C), T3 (Ta=65° C) Class I, Zone 1, AEx d IIB + H₂ Enclosure Typical 4/IP55

    Communication

    • Modbus RTU Communication-Alarms, Flow Status & Diagnostics
    • RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software

    Cover - for Local Enclosure

    • Blind Cover - Flameproof
    • Glass Lens Cover - Flameproof

    Electronics - Standard Features

    • *Configurable only from the Kayden RCM Software
    • 100 % Digital Design. Electronics are Environmentally Sealed
    • 4-Adjustable Independent Switch Point Timers
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out*
    • Easy Setup: No Mechanical Jumpers or Trim Pots
    • Incrementally Adjustable Heater Power (5 % Steps) with Automatic Over-Range Protection
    • Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
    • Temperature Compensation
    • Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode

    Enclosure Finish

    • Powder-Coated Polyester TGIC

    Enclosure, Body Details

    • 1” NPT Female Conduit Connection
    • Buna-N O-Ring on Cover

    Enclosure, Body Material

    • Copper-Free Aluminum (Does Not Exceed 0.4 % Copper)

    Environmental Protection

    • IP55
    • NEMA 4 / IP55

    Flange Material

    • 316, 316L Stainless Steel
    • Other Exotic Metals Available

    Flange Size - 1” (DN 25)

    • 1” (DN 25) - 150#
    • 1” (DN 25) - 300#
    • 1” (DN 25) - 600#

    Flange Size - 10” (DN 250)

    • 10” (DN 250) - 150#
    • 10” (DN 250) - 300#
    • 10” (DN 250) - 600#

    Flange Size - 1-1/2” (DN 40)

    • 1-1/2” (DN 40) - 150#
    • 1-1/2” (DN 40) - 300#
    • 1-1/2” (DN 40) - 600#

    Flange Size - 2” (DN 50)

    • 2” (DN 50) - 150#
    • 2” (DN 50) - 300#
    • 2” (DN 50) - 600#

    Flange Size - 3” (DN 80)

    • 3” (DN 80) - 150#
    • 3” (DN 80) - 300#
    • 3” (DN 80) - 600#

    Flange Size - 4” (DN 100)

    • 4” (DN 100) - 150#
    • 4” (DN 100) - 300#
    • 4” (DN 100) - 600#

    Flange Size - 5” (DN 125)

    • 5” (DN 125) - 150#
    • 5” (DN 125) - 300#
    • 5” (DN 125) - 600#

    Flange Size - 6” (DN 150)

    • 6” (DN 150) - 150#
    • 6” (DN 150) - 300#
    • 6” (DN 150) - 600#

    Flange Size - 8” (DN 200)

    • 8” (DN 200) - 150#
    • 8” (DN 200) - 300#
    • 8” (DN 200) - 600#

    Flange Type

    • Raised Face (RF)
    • RTJ - Ring Typical Joint

    Input Power

    • 12-24 Vdc, 120-240 Vac, 50/60 Hz
    • Power Consumption: Maximum
    • Universal Power Input

    Insertion 'U' Length

    • Custom 'U' Lengths 2.5” to 120” (6.4 cm to 305 cm) Available in 1/2” (1.0 cm) Increments.

    Operating Pressure - Sensor

    • Maximum

    Operating Temperature - Electronics

    • -55° to 65° C (-67° to 149° F)

    Operating Temperature - Sensor

    • -45° to 200° C (-50° to 392° F)

    Output

    • 4-20 mA (Thermal Signal, Scaleable) Rates 120 Vac, Maximum

    Principle of Operation

    • Thermal, Calorimetric

    Remote Control & Monitoring Software

    • Adjust Relay Modes
    • Adjust Set Points 1 & 2
    • Load or Save User Settings
    • Lock or Unlock the Display Panel to Protect the Settings
    • Many Other Adjustable Features
    • Modify Heater Settings to Optimize Response Time
    • Monitor Operating Status
    • Operated Via a Personal Computer Locally or from a Remote Control Center
    • Visualize the Actions of the Process Via the Graphical Display

    Remote Electronics Enclosure & Cover

    • Blind Cover - Flameproof
    • Glass Lens Cover - Flameproof

    Response Time

    • Approximately 0.5 to 30 seconds

    Sensor, Probe Style

    • Insertion

    Storage Temperature

    • Product Should be Stored in a Clean & Dry Environment between -30° & 60° C (-22° & 140° F)

    Switch Point Range

    • Gases: 0.25 to 200 sfps, 0.08 to 60 SMPS - Standard Condition 21° C (70° F) at 14.7 psi (1 Atm)
    • Hydrocarbon-based Liquids: 0.01 to 5.0 FPS, 0.003 to 1.50 MPS
    • Water-based Liquids: 0.01 to 3.00 FPS, 0.003 to 0.9 MPS

    Switch Type

    • 2 SPDT Sealed Relay Contacts Rated @ 4 Amps Resistive 230 Vac or 30 Vdc, Maximum

    Wetted Materials

    • 316, 316L Stainless Steel
    • All-Welded Construction
    • Hastelloy C-276
    • Other Metals Available
    • Titanium Grade 2

    Documentation

    Similar SKUs

    812-RAA-141A-M0180-C1G0A-3E
    812-RAA-141A-M0180-C1G0A-3E
    Kayden CLASSIC 812 Flow, Level, Interface Switch & Transmitter
    Kayden Instruments
    Request a Quote
    Out of Stock
    KAYDEN CLASSIC Thermal Flow, Level,Interface Switch, Modbus, 2" 150# RF SST, 18cm, Lens, CSA/CRN
    812-RAA-141A-I0090-C1G0A-3E
    812-RAA-141A-I0090-C1G0A-3E
    Kayden CLASSIC 812 Flow, Level, Interface Switch & Transmitter
    Kayden Instruments
    Request a Quote
    Out of Stock
    KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, 2" 150# RF SST, 9"U, Lens, CSA/CRN
    812-RAA-141A-I0140-C1G0A-3E
    812-RAA-141A-I0140-C1G0A-3E
    Kayden CLASSIC 812 Flow, Level, Interface Switch & Transmitter
    Kayden Instruments
    Request a Quote
    Out of Stock
    KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, 2" 150# RF SST, 14"U, Lens, CSA/CRN
    812-RAA-141A-M0310-C1G0A-3E
    812-RAA-141A-M0310-C1G0A-3E
    Kayden CLASSIC 812 Flow, Level, Interface Switch & Transmitter
    Kayden Instruments
    Request a Quote
    Out of Stock
    KAYDEN CLASSIC Thermal Flow, Level,Interface Switch, Modbus, 2" 150# RF SST, 31cmU,Lens,CSA/CRN
    812-RAA-141A-M0210-C1G0A-3E
    812-RAA-141A-M0210-C1G0A-3E
    Kayden CLASSIC 812 Flow, Level, Interface Switch & Transmitter
    Kayden Instruments
    Request a Quote
    Out of Stock
    KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, 2" 150# RF SST, 21cm, Lens, CSA, CRN
    812-RAA-141A-I0040-C1G0A-3E
    812-RAA-141A-I0040-C1G0A-3E
    Kayden CLASSIC 812 Flow, Level, Interface Switch & Transmitter
    Kayden Instruments
    Request a Quote
    Out of Stock
    KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, 2" 150# RF SST, 4"U, Lens, CSA/CRN
    812-RAA-141A-I0055-C1G0A-3E
    812-RAA-141A-I0055-C1G0A-3E
    Kayden CLASSIC 812 Flow, Level, Interface Switch & Transmitter
    Kayden Instruments
    Request a Quote
    Out of Stock
    KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, 2" 150# RF SST, 5.5"U,Lens,CSA/CRN
    812-RAA-141A-I0075-C1G0A-3E
    812-RAA-141A-I0075-C1G0A-3E
    Kayden CLASSIC 812 Flow, Level, Interface Switch & Transmitter
    Kayden Instruments
    $2,243.13USD
    Out of Stock
    KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, 2" 150# RF SST, 7.5"U, Lens, CSA/CRN