Images are representations only.
SENSY Tensiometer on Cable Load Cell, 200% Breaking Load, IP67, Cable,
Price
Request a Quote
Stock
Out of Stock
- Capacity: 60,000 Lbs
- Breaking Load: 200%
- Maximum Operating Load: 110%
- Accuracy Class: SL
- Cable Length: 10m
- Output Signal (Sensitivity): ±1.5 mV/V
- Protection: IP67
- Special Options:
- B-M12 STAINLESS
- Binder stainless steel connector M12
- K-CABLE PET 4X0.25
- Polyethylene cable IGUS 4 conductors
- Q-DB9 COND-USB
- DB9 connector male at cable end for COND-USB
- X-LONG CABLE
- 10 meter
- B-M12 STAINLESS
Description
- Capacity: 60,000 Lbs
- Breaking Load: 200%
- Maximum Operating Load: 110%
- Accuracy Class: SL
- Cable Length: 10m
- Output Signal (Sensitivity): ±1.5 mV/V
- Protection: IP67
- Special Options:
- B-M12 STAINLESS
- Binder stainless steel connector M12
- K-CABLE PET 4X0.25
- Polyethylene cable IGUS 4 conductors
- Q-DB9 COND-USB
- DB9 connector male at cable end for COND-USB
- X-LONG CABLE
- 10 meter
- B-M12 STAINLESS
Product Series Specifications
Specifications
Brand
Applications
- Hookload Sensor for Drilling & Mud-logging
- Tension Measurement for Suspended Bridges & Foot-bridges, Big Tops
- Tension Measurement of Cable, Rope, Shrouds & Riggings of Electric Pylons, Transmission Antenna's, Towers, Flare Masts, barge Mooring Lines
Approvals & Certifications
- ATEX Intrinsic Safety Ex II 1 GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
- CE
- CSA
- IECEx
Cable Length
- 19.69 feet (6 metres)
Capacity
- 1 to 80 T
Communication
- RS-232C, RS-485
- USB
Electrical Connectors
- DIN 45322
Enclosure, Body Material
- Alloy Steel
- Stainless Steel
Environmental Protection
- IP67
- IP68
Excitation Voltage
- 10 Vdc
- 3-12 Vdc - Nominal Range
Insulation Resistance
- > 5,000 megaohms
Load
- Breaking Load: > 300 % of Full Scale
- Permissible Dynamic Loading: 70 % of Full Scale
Load Limit
- 200 % of Full Scale
Resistance
- Input/Output: 352 ± 2 ohms
Sensitivity
- Nominal Sensitivity: ± 1 mV/V
Service Temperature
- -30° to 70° C (-22° to 158° F)
Storage Temperature
- -50° to 85° C (-58° to 185° F)
Temperature Coefficient
- < ± 0.1 % of Full Scale/10° C (18° F)
Product Series Documentation
Documentation
Similar SKUs

5560S-45T-SL
5560S/5565S Static Line Tensiometer
Sensy
Request a Quote
Out of Stock
SENSY Tensiometer on Cable Load Cell, Capacity 45t, 300% Breaking Load, IP67, 6m Cable, ATEX

5560S-75T-SL
5560S/5565S Static Line Tensiometer
Sensy
Request a Quote
Out of Stock
SENSY Tensiometer on Cable Load Cell, Capacity 75t (150klbs), 300% Breaking Load, IP67, ATEX

5560S-60T-SL
5560S/5565S Static Line Tensiometer
Sensy
Request a Quote
Out of Stock
SENSY Tensiometer on Cable Load Cell, Capacity 60t (135klbs), 300% Breaking Load, IP67, ATEX

5300-10T-SL
5300 Standard Load Pin
Sensy
Request a Quote
Out of Stock
SENSY Load Pin, Capacity 10t, 500% Breaking Load, ±1 mV/V Output Signal, IP67, 6m Cable, SL

5560S-15T-SL
5560S/5565S Static Line Tensiometer
Sensy
Request a Quote
Out of Stock
SENSY Tensiometer on Cable Load Cell, Capacity 15t, 300% Breaking Load, IP67, 6m Cable, ATEX

5000M-1"1/8-5T-SL
5000 Custom Load Pin
Sensy
Request a Quote
Out of Stock
SENSY Load Measuring Shackle, 15klb Capacity, 300% Breaking Load, 150% Max Operating Load, IP67M, SL

5300-1T-SL
5300 Standard Load Pin
Sensy
Request a Quote
Out of Stock
SENSY Load Pin, Capacity 1t, 500% Breaking Load, +/- 1mV/V Output Signal, IP65, CSA, 6m Cable

5000-HOIS003979
5000 Custom Load Pin
Sensy
Request a Quote
Out of Stock
SENSY Load Pin, Capacity 320 kN, 500% Breaking Load, 16 mA, IP67, 61m Cable