Images are representations only.

KAYDEN CLASSIC Thermal Flow & Level Switch, Modbus, In-Line, 3/4" FNPT, SST Ni Braze, Blind, CSA

Price
$2,149.50USD
Stock
1 - 2 weeks
  • 830: Kayden In-line Threaded Series
  • R: Sensor Type: -45°C to +200°C (-50°F to +392°F) Continuous Service
  • A3: Sensor Material: 316/316L Stainless Steel c/w Nickel Braze
  • D: Process Connection - FNPT: 3/4"
  • 0035: Sensor Assembly Body Length: 3.5" (8.8 cm)
  • A: Bleed Port: Standard
  • H: Sensor Mounting Orientation: Horizontal Pipe
  • 1: Injection Tube: Type 1; .180" Bore; 316/316L Stainless Steel
  • A: Mounting Bracket Kit: Not required
  • C: Power: 12-24 VDC and 115-230 VAC, 50 to 60 Hz
  • 1: Local Enclosure: Flameproof Aluminum
  • B: Cover for Local/Sensor Enclosure: Blind Cover - Flameproof
  • 0A: Remote Electronics: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA
  • E: Language: English
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • 830: Kayden In-line Threaded Series
  • R: Sensor Type: -45°C to +200°C (-50°F to +392°F) Continuous Service
  • A3: Sensor Material: 316/316L Stainless Steel c/w Nickel Braze
  • D: Process Connection - FNPT: 3/4"
  • 0035: Sensor Assembly Body Length: 3.5" (8.8 cm)
  • A: Bleed Port: Standard
  • H: Sensor Mounting Orientation: Horizontal Pipe
  • 1: Injection Tube: Type 1; .180" Bore; 316/316L Stainless Steel
  • A: Mounting Bracket Kit: Not required
  • C: Power: 12-24 VDC and 115-230 VAC, 50 to 60 Hz
  • 1: Local Enclosure: Flameproof Aluminum
  • B: Cover for Local/Sensor Enclosure: Blind Cover - Flameproof
  • 0A: Remote Electronics: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA
  • E: Language: English
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

Specifications

Accuracy

  • Flow Service: ± 1.0 % of Set Point over Operating Range of ± 28° C (50° F)
  • Level Service: ± 0.64 cm (0.25”)

Applications

  • Flow

Approvals & Certifications

  • CRN - Canadian Registration Number - the Kayden Classic 830 does not have a CRN Number
  • CSA
  • CSA - Local (Sensor) Enclosure Flameproof: Class I, Div. 1, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Group IIB + H₂) Temperature Code: T3 Enclosure Typical 4, IP55 Single Seal Approved Per ANSI/ISA 12.27.01-2003
  • CSA - Remote Electronics Enclosure - Optional Flameproof: Class I, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Groups IIB + H₂) Temperature Code: T3
  • FM
  • FM - Local (Sensor) Enclosure Flameproof: Class I, Div. 1, Groups B, C, D Temperature Codes: T2D (Ta=75° C), T3 (Ta=65° C) Class I, Zone 1, AEx d IIB + H₂ Enclosure Typical 4/IP55
  • FM - Remote Electronics Enclosure - Optional Flameproof: Class I, Div. 1, Groups B, C, D Temperature Codes: T2D (Ta=75° C), T3 (Ta=65° C) Class I, Zone 1, AEx d IIB + H₂ Enclosure Typical 4/IP55

Bleed Port

  • 1/4” Threaded

Communication

  • Modbus RTU Communication-Alarms, Flow Status & Diagnostics
  • RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software

Cover - for Local Enclosure

  • Blind Cover - Flameproof
  • Glass Lens Cover - Flameproof

Electronics - Standard Features

  • *Configurable only from the Kayden RCM Software
  • 100 % Digital Design. Electronics are Environmentally Sealed
  • 4-Adjustable Independent Switch Point Timers
  • Automated Redundant Self-Test Diagnostics
  • Display Panel Lock-Out*
  • Easy Setup: No Mechanical Jumpers or Trim Pots
  • Incrementally Adjustable Heater Power (5 % Steps) with Automatic Over-Range Protection
  • Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
  • Start-Up Bypass Timer
  • Temperature Compensation
  • Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode

Enclosure Finish

  • Powder-Coated Polyester TGIC

Enclosure, Body Details

  • 1” NPT Female Conduit Connection
  • Buna-N O-Ring on Cover

Enclosure, Body Material

  • Copper-Free Aluminum (Does Not Exceed 0.4 % Copper)

Environmental Protection

  • IP55
  • IP67
  • NEMA 4X
  • TYPE 4

Injection Tubes - 3/4” Male NPT x 1/4” Female NPT

  • Not Required
  • Typical 1, 0.180” Bore, 316 Stainless Steel
  • Typical 2, 0.086” Bore, 316 Stainless Steel

Input Power

  • 12-24 Vdc, 120-240 Vac, 50/60 Hz
  • Power Consumption: Max.
  • Universal Power Input

NPT Connection

  • 3/4” NPT Female

Operating Pressure - Sensor

  • Threaded Style: Max.

Operating Temperature - Electronics

  • -55° to 65° C (-67° to 149° F)

Operating Temperature - Sensor

  • -45° to 200° C (-50° to 392° F)

Output

  • 4-20 mA (Thermal Signal, Scaleable)

Principle of Operation

  • Thermal, Calorimetric

Remote Control & Monitoring Software

  • Adjust Relay Modes
  • Adjust Set Points 1 & 2
  • Load or Save User Settings
  • Lock or Unlock the Display Panel to Protect the Settings
  • Many Other Adjustable Features
  • Modify Heater Settings to Optimize Response Time
  • Monitor Operating Status
  • Operated Via a Personal Computer Locally or from a Remote Control Center
  • Visualize the Actions of the Process Via the Graphical Display

Remote Electronics Enclosure & Cover

  • Blind Cover - Flameproof
  • Glass Lens Cover - Flameproof

Response Time

  • Approximately 0.5 to 30 seconds

Sensor Assembly Body Lengths

  • In-Line Body Length is 3.5” (8.8 cm)

Sensor Orientation

  • Horizontal
  • Vertical

Sensor, Probe Style

  • InLine

Storage Temperature

  • Product Should be Stored in a Clean & Dry Environment between -30° & 60° C (-22° & 140° F)

Switch Point Range

  • Gases: 0.6 to 20,000 cc/second Standard Condition: 20° C (70° F) at 14.7 psi (1 Atm)
  • Hydrocarbon-based Liquids: 0.035 to 110 cc/second
  • Water-based Liquids: 0.015 to 50 cc/second

Switch Type

  • 2 SPDT Sealed Relay Contacts Rated @ 4 Amps Resistive 230 Vac or 30 Vdc, Max.

Wetted Materials

  • 316, 316L Stainless Steel with Nickel Brazing

Documentation

Similar SKUs

810-RAD-I0280-C1G0A-1E
810-RAD-I0280-C1G0A-1E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
$2,370.38USD
1 - 2 weeks
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 28"U, SST, Lens, CSA
P42-RA3D-0035-AH0AM
P42-RA3D-0035-AH0AM
Kayden CLASSIC 830 Spare Sensor, In-Line Threaded, 3/4" FNPT, P42 Series
Kayden Instruments
$1,185.93USD
9 In Stock
KAYDEN CLASSIC 816 Series Thermal Flow, Level, Interface Sensor, 3/4" NPT, 3.5" Body, 1/4" Bleed Port
810-RAE-0040-C1B0A-1E
810-RAE-0040-C1B0A-1E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
$1,395.69USD
In Stock 2 - 4 weeks
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 4"U, SST, Blind, CSA
812-RAA-142A-I0090-C1G0A-1E
812-RAA-142A-I0090-C1G0A-1E
Kayden CLASSIC 812 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
In Stock 3 - 7 days
KAYDEN CLASSIC Thermal Flow,Level,Interface Switch, Modbus, 2" 300# RF SST, 9"U, Lens, CSA
810-RAC-0012-C1B0A-1E
810-RAC-0012-C1B0A-1E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
$1,328.24USD
1 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U, SST, Blind, CSA
810-RAD-0020-C1B0A-1E
810-RAD-0020-C1B0A-1E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
$1,328.24USD
5 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 2"U, SST, Blind, CSA
810-RAD-0030-C1B0A-9E
810-RAD-0030-C1B0A-9E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
$1,362.34USD
1 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 3"U, SST, Blind, FM
810-RAD-0030-C1G0A-1E
810-RAD-0030-C1G0A-1E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
$1,529.85USD
3 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 3"U, SST, Lens, CSA