Images are representations only.

PD6870 ProtEX FarVu Explosion-Proof Large Display Loop-Powered Meter

Brand: Precision Digital Corporation
The PD6870 is an FM Approved, CSA Certified and ATEX and IECEx Certified explosion-proof loop-powered indicator that is easy to install and program.

It can be seen from considerable distance and even in bright sunlight.

The fact that this meter is loop-powered means that there is no need to run additional, costly power lines into a hazardous area.

The meter gets all of the power it needs from the 4-20 mA loop and its 1 V drop results in a minimal burden on the loop.

The meter features a wide -40 to +75°C operating temperature range and comes with two ¾" NPT threaded conduit openings and flanges for wall or pipe mounting.

Calibration is a quick two-step process involving the adjustment of only high and low, non-interacting potentiometers.
Features
  • Explosion-Proof / Flame-Proof Loop-Powered Process Meter
  • 4-20 mA Input
  • 1.0" or 25.4 mm 3½ Digits LCD Display; -1999 to 1999
  • 1 Volt Drop - 4 Volt Drop with Backlight
  • HART® Protocol Transparent
  • Loop-Powered Backlight Option
  • Operates from -40 to 75°C / -40 to 167°F
  • Coarse and Fine Zero & Span Potentiometer Adjustments for Easy Field Scaling
  • Flanges for Wall or Pipe Mounting
  • Explosion-Proof, IP68, NEMA 4X Die-Cast Aluminum Enclosure
  • FM Approved as Explosion-Proof / Dust-Ignition Proof / Flame-Proof
  • CSA Certified as Explosion-Proof / Dust-Ignition Proof
  • ATEX and IECEx Certified as Flame-Proof
  • Conformal Coated PCBs for Dust and Humidity Protection
  • Two ¾" NPT Threaded Conduit Openings - One Plug Installed
  • Pipe Mounting Kits
  • Stainless Steel Tag Available
show more
The PD6870 is an FM Approved, CSA Certified and ATEX and IECEx Certified explosion-proof loop-powered indicator that is easy to install and program.

It can be seen from considerable distance and even in bright sunlight.

The fact that this meter is loop-powered means that there is no need to run additional, costly power lines into a hazardous area.

The meter gets all of the power it needs from the 4-20 mA loop and its 1 V drop results in a minimal burden on the loop.

The meter features a wide -40 to +75°C operating temperature range and comes with two ¾" NPT threaded conduit openings and flanges for wall or pipe mounting.

Calibration is a quick two-step process involving the adjustment of only high and low, non-interacting potentiometers.
Features
  • Explosion-Proof / Flame-Proof Loop-Powered Process Meter
  • 4-20 mA Input
  • 1.0" or 25.4 mm 3½ Digits LCD Display; -1999 to 1999
  • 1 Volt Drop - 4 Volt Drop with Backlight
  • HART® Protocol Transparent
  • Loop-Powered Backlight Option
  • Operates from -40 to 75°C / -40 to 167°F
  • Coarse and Fine Zero & Span Potentiometer Adjustments for Easy Field Scaling
  • Flanges for Wall or Pipe Mounting
  • Explosion-Proof, IP68, NEMA 4X Die-Cast Aluminum Enclosure
  • FM Approved as Explosion-Proof / Dust-Ignition Proof / Flame-Proof
  • CSA Certified as Explosion-Proof / Dust-Ignition Proof
  • ATEX and IECEx Certified as Flame-Proof
  • Conformal Coated PCBs for Dust and Humidity Protection
  • Two ¾" NPT Threaded Conduit Openings - One Plug Installed
  • Pipe Mounting Kits
  • Stainless Steel Tag Available

Specifications

Accuracy

  • ± 0.1 %

Approvals & Certifications

  • ATEX, II 2 GD. Ex d IIC T6 Gb. Ex Tb IIIC T85° C Db
  • CSA Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G, Class III, Div. 1, T6. Class I, Zone 1, Ex d IIC T6
  • FM Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G, Class III, Div. 1, T6. Class I, Zone 1, AEx d IIC T6 Gb. Zone 21, AEx Tb IIIC T85° C
  • IEC Ex d IIC T6 Gb. Ex Tb IIIC T85° C Db

Conduit Connection

  • 3/4” NPT

Display

  • 1”
  • 3-1/2-Digit LCD

Enclosure, Body Material

  • Explosion-proof Die Cast Aluminum with Glass Window

Environmental Protection

  • IP66
  • IP68
  • NEMA 4X

Humidity

  • 0 to 90 % Non-Condensing

Input

  • 4-20 mA

Operating Temperature

  • -40° to 75° C (-40° to 167° F)

Storage Temperature

  • -40° to 75° C (-40° to 167° F)

Update Time

  • 2.5 seconds

Voltage Drop

  • 1 Vdc at 20 mA without Backlight
  • 4 Vdc at 20 mA with Loop-Powered Backlight