Images are representations only.

5910 Low Profile Compression Load Cell

Brand: Sensy - Sensors & Synergy S.A.
Load cell combining high capacity with low design.
Features
  • Stainless steel
  • Protection IP 67
  • Low design
  • Sturdy design
  • Cable length: 3 m
  • Available options (non exhaustive list):
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • High service temperature (150° C)
show more
Load cell combining high capacity with low design.
Features
  • Stainless steel
  • Protection IP 67
  • Low design
  • Sturdy design
  • Cable length: 3 m
  • Available options (non exhaustive list):
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • High service temperature (150° C)

Specifications

Accuracy

  • 0.1 % of Full Scale
  • 0.25 % of Full Scale

Applications

  • Hoppers
  • Reactors
  • Silos
  • Tanks

Approvals & Certifications

  • ATEX Intrinsic Safety Ex II 1 GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
  • CE

Cable Length

  • 10 feet (3 metres)

Capacity

  • 0.3 to 5 T

Enclosure, Body Material

  • Stainless Steel

Environmental Protection

  • IP67

Excitation Voltage

  • 10 Vdc
  • 3-12 Vdc - Nominal Range

Insulation Resistance

  • > 5,000 megaohms

Linearity

  • < ± 0.1 % to < ± 0.25 % of Full Scale

Load

  • Breaking Load: > 300 % of Full Scale
  • Permissible Dynamic Loading: 40 % of Full Scale

Load Limit

  • 150 % of Full Scale

Repeatability

  • < ± 0.03 % to < ± 0.1 % of Full Scale

Resistance

  • Input/Output: 702 ± 2 ohms

Sensitivity

  • Nominal Sensitivity: 1.5 mV/V
  • Tolerance: < ± 0.3 %

Service Temperature

  • -30° to 70° C (-22° to 158° F)

Static Lateral Force

  • 10 % of Full Scale

Storage Temperature

  • -50° to 85° C (-58° to 185° F)

Zero Balance

  • ± 0.02 mV/V