Images are representations only.

604TU Series Temperature Switch

Brand: Custom Control Sensors, LLC
Does not ship to United States
The 604TU Series is a general purpose temperature switch with a stainless steel capillary tube and armored jacket probe port fitting.

It is constructed with an integral terminal box and switch design and easy set point adjustment.

It is also easily mounted to bulkheads and UL certified with NEMA 4 and IP65 rating. It has high vibration and shock resistance utilizing Dual Snap® disc spring technology.
Features
  • Adjustable Set Point Range:
    • Increasing: -30° to 630° F, -34° to 332° C
    • Decreasing: -39° to 624° F, -39° to 329° C
  • Deadband: Approximately
    • At Bottom of Range: 9° to 24° F, 5° to 13° C
    • At Top of Range: 3° to 6° F, 2° to 8° C
  • Probe Temperature (Maximum): 200° to 650° F, 93° to 343° C
  • Wetted Materials:
    • Temperature Probe: 300 Stainless Steel & Graphite
    • Capillary Tube: Lubricated Glass Fiber
  • Relay: SPDT or DPDT
  • UL, CE Mark, General Purpose
show more
The 604TU Series is a general purpose temperature switch with a stainless steel capillary tube and armored jacket probe port fitting.

It is constructed with an integral terminal box and switch design and easy set point adjustment.

It is also easily mounted to bulkheads and UL certified with NEMA 4 and IP65 rating. It has high vibration and shock resistance utilizing Dual Snap® disc spring technology.
Features
  • Adjustable Set Point Range:
    • Increasing: -30° to 630° F, -34° to 332° C
    • Decreasing: -39° to 624° F, -39° to 329° C
  • Deadband: Approximately
    • At Bottom of Range: 9° to 24° F, 5° to 13° C
    • At Top of Range: 3° to 6° F, 2° to 8° C
  • Probe Temperature (Maximum): 200° to 650° F, 93° to 343° C
  • Wetted Materials:
    • Temperature Probe: 300 Stainless Steel & Graphite
    • Capillary Tube: Lubricated Glass Fiber
  • Relay: SPDT or DPDT
  • UL, CE Mark, General Purpose

Specifications

Adjustment Type

  • Field Adjustable

Approvals & Certifications

  • CE
  • CRN
  • CRN - Alberta
  • CRN - British Columbia
  • CRN - Manitoba
  • CRN - N.W. Territories
  • CRN - Saskatchewan
  • CSA
  • cUL
  • EMC
  • LVD
  • PED
  • RoHS
  • UL

Capillary Length

  • 10 feet (3 metres)
  • 15 feet
  • 25 feet
  • 5 feet (1.524 metres)

Capillary Material

  • Lubricated Glass Fiber

Deadband, Approximate - Bottom of Range

  • -13° to -4° C (9° to 25° F)
  • 4° to 13° C (39° to 55° F)

Deadband, Approximate - Top of Range

  • -16° to -14° C (3° to 6° F)
  • 2° to 8° C (36° to 46° F)

Electrical Connectors

  • Terminal Strip - Internal

Electrical Contacts

  • Gold
  • Silver

Electrical Rating

  • 1 A at 125 Vac, 50/60 Hz
  • 15 A at 125/250/480 Vac Resistive, 0.4 A at 125 Vdc, 0.2 A at 250 Vdc
  • 5 A at 125/250 Vac Resistive, 5 A at 28 Vdc, 0.5 A at 125 Vdc

Enclosure, Body Material

  • Aluminum

Environmental Protection

  • IP65
  • IP66
  • NEMA 13
  • NEMA 4, 13 / IP65, 66

Maximum Sensor, Probe Temperature

  • 121° to 343° C (250° to 650° F)

NACE & NIST

  • NACE MR-0175: 2003

NPT Connection

  • 1/2” NPT Male

O-Ring Material

  • None

Operating Temperature

  • -40° to 86° C (-40° to 187° F)

Proof Pressure

  • bar: 103.4
  • kPa: 10,342
  • psig: 1,500

Sensor, Probe Material

  • Stainless Steel & Graphite

Set Point - Decreasing

  • -39° to 329° C
  • -39° to 329° C (-38° to 624° F)

Set Point - Increasing

  • -34° to 332° C
  • -34° to 332° C (-29° to 630° F)

Standard Features

  • Internal Case Ground
  • Weatherproof

Switch Type

  • DPDT
  • SPDT

System Pressure

  • bar: 86
  • kPa: 8,618
  • psig: 1,250

Typical Applications

  • Power Generation
  • Rail Car
  • Fluid Management
  • Manufacturing Process
  • Utilities, Water Treatment and Waste
  • Chemical Refining and Processing
  • Heavy Vehicles
  • Safety Systems