Universal load cell combining sturdy design, high accuracy and low cost.

Features:
  • Stainless steel 
  • Protection IP 67 
  • Sturdy design 
  • Complies with OIML / R60 up to 3000 d for scales in class III according to EN 45 501
  • Cable length: 8 m
  • Options:
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Amplified output (V or mA) and digital output signal (RS-232C, RS-485, USB)
read more...

Agency Approvals

  • ATEX Intrinsic Safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
  • CE

Storage Temperature

  • -50 to 85° C (-58° to 185° F)

Sensitivity

  • 2 mV/V
  • Sensitivity Tolerance: <±0.1% to <±0.3%

Accuracy

  • 0.03% of Full Scale
  • 1000 d OIML
  • 3000 d (A3 and C3 Model)

Zero Balance

  • ±0.02 mV/V

Repeatability

  • <±0.01% to <±0.02% of Full Scale

Environmental Protection

  • IP67

Resistance

  • Input/Output: 352 ±2 Ohms

Cable Length

  • 26 feet (8 meters)

Insulation Resistance

  • >5,000 MegaOhms

Communication

  • RS-232C/RS-485
  • USB

Load Limit

  • 150% of Full Scale

Excitation Voltage

  • 10 Vdc
  • 3-12 Vdc - Nominal Range

Enclosure/Body Material

  • Stainless Steel

Tests & Certificates

  • OIML / R60 up to 3000 d for scales in Class III According to EN 45 501

Applications

  • Batching System
  • Hoppers
  • Low Profile Scales
  • Packaging Equipment
  • Pallet
  • Platform Scales
  • Reactors
  • Tanks
  • Vessel

Load

  • Breaking Load: >300% of Full Scale
  • Permissible Dynamic Loading: 50% of Full Scale

Linearity

  • <±0.02% to <±0.025% of Full Scale

Service Temperature

  • -30 to 70° C (-22° to 158° F)

Static Lateral Force

  • 100% of Full Scale