• RTD or Ohm input
  • High measurement accuracy
  • 3-wire connection
  • Programmable sensor error value
  • For DIN form B sensor head mounting
Application
  • Linearized temperature measurement with Pt100...Pt1000 or Ni100...Ni1000 sensor.
  • Conversion of linear resistance variation to a standard analog current signal, for instance from valves or Ohmic level sensors.
read more...

Agency Approvals

  • ATEX 2014/34/EU KEMA 03ATEX1535 X
  • CCOE P337392/2
  • CSA 1125003
  • DNV Marine Stand. f. Certific. No. 2.4
  • EAC Ex TR-CU 012/2011
  • EAC TR-CU 020/2011
  • EMC 2014/30/EU
  • FM 2D5A7
  • IECEx DEK 13.0036X
  • INMETRO DEKRA 13.0002 X

Environmental Protection

  • IP00
  • IP68

Calibration

  • 20° to 28° C (68° to 82° F)

Temperature Range

  • -40° to 85° C (-40° to 185° F)

Humidity

  • <95% Relative Humidity (Non-Cond.)

RTD Type

  • Lin. R
  • Ni100
  • Pt100

Accuracy

  • ±0.1%

Vibration

  • ±1.6 mm
  • ±4g

Response Time

  • 0.33 to 60 Seconds

Supply Voltage

  • 8.0-35 Vdc

Output

  • 4-20 mA Signal Range

Load

  • ≤ (Vsupply-8) / 0.023 Ohms