The Kayden CLASSIC 828 Flow, Level and Interface Switch & Transmitter features a precision welded, highly accurate stainless steel sensor. It is ideal for liquids, gases & slurries in a sanitary process, and is available in a wide range of Tri-Clamp Sanitary Flange sizes. All Kayden models feature a rugged flameproof enclosure with blind or lens covers available. Kayden’s advanced digital electronics will revolutionize the way you monitor and control your process.
 
  • Process Connections: Tri-Clamp Flanged - Sanitary
    • 1", 1.5", 2", 2.5", 3", 3.5"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Insertion 'U' Length: 2", 3", 4", 6", Custom Lengths from 2.5" - 120" (6.4 cm to 305 cm) in 1/2" (1 cm) increments
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): Per Flange Rating
  • Temperature Range (Sensor): -45°C to 200°C, -50°F to 392°F
  • Local Enclosure: Aluminum Flameproof, 1" FNPT Conduit Connection
  • Cover: Blind or Glass Lens, Flameproof
  • Wetted Materials:
    • 304/316 Stainless Steel
  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus
  • Approvals:
    • FM
    • Single Seal
    • NACE
    • NEMA 4X
The above description encapsulates the entire product series. Specifications for individual configurations may vary depending on the selection chosen.
read more...

12 Models In Stock

828-RA6E-0020-C1B0A1E
828-RA6E-0020-C1B0A1E
$842.00
  • 1" Sanitary Flange (E)
  • 2" 'U' Length (0020)
  • No Remote Electronics (0A)
  • Sensor Material

    304/316 Stainless Steel - Sanitary
  • Process Connection - Sanitary Flange

    1"
  • Insertion 'U' Length

    2" (5.0 cm)
  • Cover for Local Enclosure

    Blind Cover
  • Remote Electronics Enclosure & Cover

    Not Required
  • Agency Approvals

    CSA (Canada & US)
828-RA6E-0020-C1B0A9E
828-RA6E-0020-C1B0A9E
$842.00
  • 1" Sanitary Flange (E)
  • 2" 'U' Length (0020)
  • No Remote Electronics (0A)
  • Sensor Material

    304/316 Stainless Steel - Sanitary
  • Process Connection - Sanitary Flange

    1"
  • Insertion 'U' Length

    2" (5.0 cm)
  • Cover for Local Enclosure

    Blind Cover
  • Remote Electronics Enclosure & Cover

    Not Required
  • Agency Approvals

    FM
828-RA6E-0020-C1B1G1E
828-RA6E-0020-C1B1G1E
$1,533.00
  • 1" Sanitary Flange (E)
  • 2" 'U' Length (0020)
  • Remote Electronics: Glass Cover (1G)
  • Sensor Material

    304/316 Stainless Steel - Sanitary
  • Process Connection - Sanitary Flange

    1"
  • Insertion 'U' Length

    2" (5.0 cm)
  • Cover for Local Enclosure

    Blind Cover
  • Remote Electronics Enclosure & Cover

    Glass Lens Cover
  • Agency Approvals

    CSA (Canada & US)
828-RA6E-0020-C1G0A1E
828-RA6E-0020-C1G0A1E
$912.00
  • 1" Sanitary Flange (E)
  • 2" 'U' Length (0020)
  • Glass Local Lens Cover (G)
  • No Remote Electronics (0A)
  • Sensor Material

    304/316 Stainless Steel - Sanitary
  • Process Connection - Sanitary Flange

    1"
  • Insertion 'U' Length

    2" (5.0 cm)
  • Cover for Local Enclosure

    Glass Lens Cover
  • Remote Electronics Enclosure & Cover

    Not Required
  • Agency Approvals

    CSA (Canada & US)
828-RA6E-0020-C1G1G1E
828-RA6E-0020-C1G1G1E
$1,697.00
  • 1" Sanitary Flange (E)
  • 2" 'U' Length (0020)
  • Glass Local Lens Cover (G)
  • Remote Electronics: Glass Cover (1G)
  • Sensor Material

    304/316 Stainless Steel - Sanitary
  • Process Connection - Sanitary Flange

    1"
  • Insertion 'U' Length

    2" (5.0 cm)
  • Cover for Local Enclosure

    Glass Lens Cover
  • Remote Electronics Enclosure & Cover

    Glass Lens Cover
  • Agency Approvals

    CSA (Canada & US)
828-RA6E-0030-C1B0A9E
828-RA6E-0030-C1B0A9E
$767.00
  • 1" Sanitary Flange (E)
  • 3" 'U' Length (0030)
  • No Remote Electronics (0A)
  • Sensor Material

    304/316 Stainless Steel - Sanitary
  • Process Connection - Sanitary Flange

    1"
  • Insertion 'U' Length

    3" (7.5 cm)
  • Cover for Local Enclosure

    Blind Cover
  • Remote Electronics Enclosure & Cover

    Not Required
  • Agency Approvals

    FM
828-RA6G-0030-C1B0A1E
828-RA6G-0030-C1B0A1E
$767.00
  • 1.5" Sanitary Flange (G)
  • 3" 'U' Length (0030)
  • No Remote Electronics (0A)
  • Sensor Material

    304/316 Stainless Steel - Sanitary
  • Process Connection - Sanitary Flange

    1.5"
  • Insertion 'U' Length

    3" (7.5 cm)
  • Cover for Local Enclosure

    Blind Cover
  • Remote Electronics Enclosure & Cover

    Not Required
  • Agency Approvals

    CSA (Canada & US)
828-RA6G-0040-C1B0A1E
828-RA6G-0040-C1B0A1E
$767.00
  • 1.5" Sanitary Flange (G)
  • 4" 'U' Length (0040)
  • No Remote Electronics (0A)
  • Sensor Material

    304/316 Stainless Steel - Sanitary
  • Process Connection - Sanitary Flange

    1.5"
  • Insertion 'U' Length

    4" (10.1 cm)
  • Cover for Local Enclosure

    Blind Cover
  • Remote Electronics Enclosure & Cover

    Not Required
  • Agency Approvals

    CSA (Canada & US)
828-RA6H-0020-C1B0A1E
828-RA6H-0020-C1B0A1E
$987.00
  • 2" Sanitary Flange (H)
  • 2" 'U' Length (0020)
  • No Remote Electronics (0A)
  • Sensor Material

    304/316 Stainless Steel - Sanitary
  • Process Connection - Sanitary Flange

    2"
  • Insertion 'U' Length

    2" (5.0 cm)
  • Cover for Local Enclosure

    Blind Cover
  • Remote Electronics Enclosure & Cover

    Not Required
  • Agency Approvals

    CSA (Canada & US)
828-RA6H-0020-C1B0A9E
828-RA6H-0020-C1B0A9E
$748.00
  • 2" Sanitary Flange (H)
  • 2" 'U' Length (0020)
  • No Remote Electronics (0A)
  • Sensor Material

    304/316 Stainless Steel - Sanitary
  • Process Connection - Sanitary Flange

    2"
  • Insertion 'U' Length

    2" (5.0 cm)
  • Cover for Local Enclosure

    Blind Cover
  • Remote Electronics Enclosure & Cover

    Not Required
  • Agency Approvals

    FM
828-RA6H-0040-C1G0A1E
828-RA6H-0040-C1G0A1E
$931.00
  • 2" Sanitary Flange (H)
  • 4" 'U' Length (0040)
  • Glass Local Lens Cover (G)
  • No Remote Electronics (0A)
  • Sensor Material

    304/316 Stainless Steel - Sanitary
  • Process Connection - Sanitary Flange

    2"
  • Insertion 'U' Length

    4" (10.1 cm)
  • Cover for Local Enclosure

    Glass Lens Cover
  • Remote Electronics Enclosure & Cover

    Not Required
  • Agency Approvals

    CSA (Canada & US)
RA6H-0020-C1G0A9E
RA6H-0020-C1G0A9E
$912.00
  • Process Connections: Tri-Clamp Flanged - Sanitary
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 2500 psi, 1723 kPa, 0.01723 bar
  • Temperature Range (Sensor): -55°C to 200°C, -67°F to 392°F
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Cover
  • Remote Electronics Enclosure and Cover: Not Selected
  • Wetted Materials:
    • Standard: 316 Stainless Steel
  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus
  • FM, NACE, NEMA 4

Selected Configuration

Model #:

828-RA6E-0030-C1B0A9E

Price:
$767.00 USD
Availability:
Ships 10 - 15 Days
Min. Qty:
1 Item

Configuration

reset configuration

Agency Approvals

  • CRN - Canadian Registration Number - The Kayden Classic 828 does not have a CRN Number


  • CSA - Local (Sensor) Enclosure
    • Flameproof: Class I, Division 1, Groups B, C and D; Ex d IIB + H2
    • AEx d IIB + H2 (Class I, Zone 1, Group IIB + H2)
    • Temperature Code: T3
    • Enclosure Type 4 / IP55
    • Single Seal Approved per ANSI / ISA 12.27.01-2003
  • CSA - Remote Electronics Enclosure - Optional
    • Flameproof: Class I, Groups B, C and D; Ex d IIB + H2
    • AEx d IIB + H2 (Class I, Zone 1, Groups IIB + H2)
    • Temperature Code: T3
  • FM - Local (Sensor) Enclosure
    • Flameproof: Class I, Division 1, Groups B, C and D
    • Temperature Codes: T2D (Ta=75º C); T3 (Ta=65º C)
    • Class I, Zone 1, AEx d IIB + H2
    • Enclosure Type 4 / IP55
  • FM - Remote Electronics Enclosure - Optional
    • Flameproof: Class I, Division 1, Groups B, C and D
    • Temperature Codes: T2D (Ta=75º C), T3 (Ta=65º C)
    • Class I, Zone 1, AEx d IIB + H2
    • Enclosure Type 4 / IP55
  • UL

Principle of Operation

  • Thermal (Calorimetric)

Operating Pressure - Sensor

  • Sanitary Tri-Clamp Style: Maximum Available Working Pressure to psig: 250 (bar: 17.2, kPa: 1,723) at 21° C (70° F)

Operating Temperature - Electronics

For temperatures above +65° C (+149° F), the electronics must be remotely mounted. 
  • -55° to 65° C (-67° to 149° F)

Operating Temperature - Sensor

  • -45° to 200° C (-50° to 392° F)

Storage Temperature

  • Product should be stored in a clean and dry environment between -30° and 60° C (-22° and 140° F)

Switch Point Range

  • Gases: 0.25 to 200 SFPS, 0.08 to 60 SMPS - standard condition 21° C (70° F) at 14.7 psi (1 atm)
  • Hydrocarbon-based Liquids: 0.01 to 5.0 FPS, 0.003 to 1.50 MPS
  • Water-based Liquids: 0.01 to 3.00 FPS, 0.003 to 0.9 MPS

Accuracy

  • Flow Service: ±1.0% of Set Point Velocity over Operating Range of ±28º C (±50º F)
  • Level Service: ±0.64 cm (0.25")

Response Time

  • Approximately 0.5 to 30 Seconds

Process Connection - Other

  • 1" Sanitary Clamp
  • 1-1/2" Sanitary Clamp
  • 2" Sanitary Clamp
  • 2-1/2" Sanitary Clamp
  • 3" Sanitary Clamp
  • 3-1/2" Sanitary Clamp

Insertion 'U' Length

2" is standard.
  • 2" (5 cm)
  • 3" (7.5 cm)
  • 4" (10.1 cm)
  • 6" (15.2 cm)
  • Custom 'U' Lengths 2.5" to 120" (6.4 cm to 305 cm) Available in 1/2" (1.0 cm) Increments.

Environmental Protection

  • NEMA 4 / IP55

Switch Type

  • 2 SPDT sealed relay contacts rated @ 4 amps resistive 230 VAC or 30 VDC Max, individually adjustable

Input Power

  • 12-24 Vdc; 120-240 Vac, 50-60 Hz
  • Power Consumption: Maximum 4.8 W (Fully Configured)
  • Universal Power Input

Communication

  • MODBUS RTU Communication-Alarms, Flow Status and Diagnostics
  • RS-485 using Kayden's Remote Control and Monitoring Software (RCMS) or other Modbus Compatible Software

Output

  • 4-20 mA (Thermal Signal, Scaleable)

Remote Control and Monitoring Software

  • Adjust Relay Modes
  • Adjust Set Points 1 and 2
  • Load or Save User Settings
  • Lock or Unlock the Display Panel to Protect the Settings
  • Many other Adjustable Features
  • Modify Heater Settings to Optimize Response Time
  • Monitor Operating Status
  • Operated via a Personal Computer Locally or from a Remote Control Center
  • Visualize the Actions of the Process via the Graphical Display

Electronics - Standard Features

  • * Only configurable from the Kayden RCM software
  • 100% Digital Design. Electronics are Environmentally Sealed
  • 4-Adjustable Independent Switch Point Timers
  • Automated Redundant Self-Test Diagnostics
  • Display Panel Lock-Out*
  • Easy Setup: No Mechanical Jumpers or Trim Pots
  • Incrementally Adjustable Heater Power (5% steps) with Automatic Over-Range Protection
  • Intelligent User Interface with Push-Button and Constant Display of Operation (Flow/Level)
  • Start-Up Bypass Timer
  • Temperature Compensation
  • Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode

Enclosure/Body Material

  • Copper-Free Aluminum (Does not exceed 0.4% Copper)

Enclosure Finish

  • Powder Coated Polyester TGIC

Flange Material

  • 304 Stainless Steel

Enclosure/Body Details

  • 1" Female NPT Conduit Connection
  • Buna-N O-Ring on Cover

Remote Electronics Enclosure and Cover

For temperatures above +65° C (+149° F), the electronics must be remotely mounted. If cables are required, we recommend the Kayden A06-XP Flameproof Cable & Connector Assembly.

These covers are acceptable for use in hazardous areas.
  • Blind Cover - Flameproof
  • Glass Lens Cover - Flameproof

Wetted Materials

  • 304/316 Stainless Steel (sanitary finish, 3A compliant)
  • All-welded construction

Cover - For Local Enclosure

For local enclosure types below, blind cover is standard.
  • Blind Cover - Flameproof
  • Glass Lens Cover - Flameproof

Sensor/Probe Style

  • Insertion

Applications

  • Flow
  • Interface
  • Level
A05-GP

A05-GP

Kayden General Purpose Remote Cable

A06-GP

A06-GP

Kayden General Purpose Cable & Connector Assembly

A06-XP

A06-XP

Kayden Flameproof Cable & Connector Assembly

A15-321

A15-321

Kayden RS232/RS485 Serial Communication Adapter

A15-322

A15-322

Kayden RS232/USB Adapter

A15-323

A15-323

Kayden RS485/USB Adapter

Flat Duct Flange

Flat Duct Flange

Kayden Flat Duct Flange Mounting Plate

Rolled Duct Flange

Rolled Duct Flange

Kayden Rolled Duct Flange Mounting Plate