Images are representations only.

IM Series Interface Module

Brand: Turck, Inc
Features
  • Input: 1, 2, or 4 Channel
  • Output: 1, 2 or 5 Non-Hazardous Switching Circuits, 0-20 mA
  • Alarm: Non-Hazardous SPST Switch for open or short circuits
  • Pin Configuration: 18 mm, 12-pin or 27 mm, 20-pin Connectors
  • Housing: Polycarbonate/ABS
  • Temperature Ranges
    • Operating: -25° to +60° C (-13° to +140° F)
    • Storage: -40° to +80° C (-40° to +176° F)
  • Operating Voltage: 20-125 Vdc (20-250 Vac) or 24 Vdc (ranges 10-30 Vdc)
  • Options
    • Relay or Transistor Output Switch
    • Voltage or Current Output
    • HART Compatibility
    • Loop Powered Input
    • Software Configurable with PC for Temperature Relay
    • Configurable Limit Value Relay Output
  • Mounting: DIN Rail or Panel
  • Protection: IP20
  • Intrinsically Safe
show more
Features
  • Input: 1, 2, or 4 Channel
  • Output: 1, 2 or 5 Non-Hazardous Switching Circuits, 0-20 mA
  • Alarm: Non-Hazardous SPST Switch for open or short circuits
  • Pin Configuration: 18 mm, 12-pin or 27 mm, 20-pin Connectors
  • Housing: Polycarbonate/ABS
  • Temperature Ranges
    • Operating: -25° to +60° C (-13° to +140° F)
    • Storage: -40° to +80° C (-40° to +176° F)
  • Operating Voltage: 20-125 Vdc (20-250 Vac) or 24 Vdc (ranges 10-30 Vdc)
  • Options
    • Relay or Transistor Output Switch
    • Voltage or Current Output
    • HART Compatibility
    • Loop Powered Input
    • Software Configurable with PC for Temperature Relay
    • Configurable Limit Value Relay Output
  • Mounting: DIN Rail or Panel
  • Protection: IP20
  • Intrinsically Safe
7 models matching criteria
TURCK Isolation Switch Relay, 4-Channel, 20-250 VAC / 20-125 VDC, Alarm, Selectable NO/NC Outputs show more
  • IM: Interface Module
  • 1: Isolation Switch Relay
  • 4: Number of Inputs
  • 5: Number of Non-Hazardous Area Outputs, Reflecting Hazardous Area Input Status
  • 1: Number of Additional Non-Hazardous Area Alarm Outputs
  • EX: Intrinsically Safe Associated Apparatus
  • T: Transistor Switch
1 In Stock
Non-Cancellable / Non-Refundable
$763.45USD
TURCK Solenoid Driver/Discrete Output Isolator, 2-Channel, Loop Powered show more
  • IM: Interface Module
  • 72: Solenoid Driver/Discrete Output Isolators
  • 2: Number of Hazardous Area Inputs
  • 2: Number of Non-Hazardous Area Current Output Channels
  • EX: Intrinsically Safe Associated Apparatus
  • L: Loop Power
3 In Stock
Non-Cancellable / Non-Refundable
$460.87USD
TURCK Temperature Converter, 1-Channel, 20-250 VAC / 20-125 VDC show more
  • IM: Interface Module
  • 34: Temperature Measuring Amplifier
  • 1: Number of Hazardous Area Inputs
  • 1: Number of Non-Hazardous Area Outputs
  • EX: Intrinsically Safe Associated Apparatus
  • I
  • Supply Voltage:  20-250 VAC, 20-125 VDC
  • Approvals: ATEX, IECEx, CFMUS, UL, TR CU, INMETRO, CCOE, NEPSI, KOSHA
2 In Stock
Non-Cancellable / Non-Refundable
$725.17USD
TURCK Isolation Switch Relay, 2-Channel, 20-250 VAC / 20-125 VDC, NPN Outputs show more
  • IM: Interface Module
  • 1: Isolation Switch Relay
  • 2: Number of Inputs
  • 2: Number of Non-Hazardous Area Outputs, Reflecting Hazardous Area Input Status
  • EX: Intrinsically Safe Associated Apparatus
  • T: Transistor Switch
2 - 8 weeks
Non-Cancellable / Non-Refundable
$387.25USD
TURCK Isolation Switch Relay, 2-Channel, 24 VDC show more
  • IM: Interface Module
  • 1: Isolation Switch Relay
  • 2: Number of Inputs
  • 2: Number of Non-Hazardous Area Outputs, Reflecting Hazardous Area Input Status
  • EX: Intrinsically Safe Associated Apparatus
  • R: Relay Switch
  • 24VDC: Supply Voltage (10-30 VDC)
2 - 8 weeks
$306.26USD
TURCK Isolation Switch Relay, 2-Channel, 20-250 VAC / 20-125 VDC show more
  • IM: Interface Module
  • 1: Isolation Switch Relay
  • 2: Number of Inputs
  • 2: Number of Non-Hazardous Area Outputs, Reflecting Hazardous Area Input Status
  • EX: Intrinsically Safe Associated Apparatus
  • R: Relay Switch
  • Universal Supply Voltage: 20-250 VAC / 20-125 VDC
2 - 8 weeks
$335.71USD
TURCK Isolator, 2-Channel HARTor Conventional Compatable Analog Input (UL Listed, CFMUS Approved) show more
  • IM: Interface Module
  • 33: Analog Input Repeaters/Supplies
  • 2: Number of Hazardous Area Inputs
  • 2: Number of Non-Hazardous Area Outputs
  • EX: Intrinsically Safe Associated Apparatus
  • HI: HART Compatible
  • 24VDC: Supply Voltage (19-29 VDC)
  • Approvals: ATEX, IECEx, UL, cFMus, TR CU, TIIS, CCOE, Kosha
  • Input Circuits: 0/4...20mA
  • Output Circuits: 0/4...20mA
  • SIL2
  • Removable terminal blocks, screwable with 2mm test socket
  • Complete galvanic isolation
  • Installation in Zone 2
  • Supply of 2-wire measuring transducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters
  • [/li]
4 - 6 weeks
Non-Cancellable / Non-Refundable
$756.09USD

Specifications

Brand

Accuracy

  • ≤ 0.1 % of Full Scale Output
  • ≤ 0.2 % of Full Scale Output

Alarm

  • None
  • Non-Hazardous Area Alarm Switch

Ambient Temperature Range

  • -25° to 70° C (-13° to 158° F)

Approvals & Certifications

  • CSA
  • FM

Circuit Protection

  • Short Circuit Current 8.2 mA

Electrical Connectors

  • 4 times 3-Pole Removable Terminal Blocks, Reverse Polarity Protected, Screw Connection

Enclosure, Body Material

  • Polycarbonate/ABS

Environmental Protection

  • IP20

Frequency

  • 40 to 70 Hz

Indication

  • LED Indicators for Readiness, Switching, & Error

Input

  • One Channel
  • Two Channel
  • Four Channel

Mounting

  • DIN Rail Mounting
  • Panel Mount

Output

  • 20-125 Vdc
  • 20-250 Vac
  • 4-20 mA

Output Format

  • Configurable Limit Value Relay Output
  • Current Output
  • Relay Output
  • Software Configurable
  • Transistor Output
  • Voltage Output

Storage Temperature

  • -40° to 80° C (-40° to 176° F)

Supply Voltage

  • 19-29 Vdc
  • 24 Vdc

Switch Type

  • SPST