Ambient Temperature: -40°C to +85°C (-40°F to +185°F)
Process Connection: 1/4"-18 NPT or 1/2"-14 NPT
Electrical Connection: 1/2"-14 NPT
Pressure Type: Differential Pressure, Pressure is applied to high and low sides and differential pressure is measured. High static pressure is supported.
Materials of Construction:
Diaphragm: 316 Stainless Steel or Hastelloy C-276
Flanges: 316 Stainless Steel
Drain/Vent Screw: 316 Stainless Steel or Hastelloy C-276
O-Rings: Buna-N, Viton (Fluorocarbon), or Teflon
The above description encapsulates the entire product series. Specifications for individual configurations may vary depending on the selection chosen.
Span Error for Ranges 2, 3, 4, 5 and 6: Correctable to ±0.2% of Reading per psi: 1,000 (bar: 68.95, kPa: 6,895)
Zero Error for Ranges 2, 3, 4, 5 and 6: ±0.033% of URL per psi: 1,000 (bar: 68.95, kPa: 6,895)
Operating Temperature - Display
-20° to 80° C (-4° to 176° F)
-40° to 85° C (-40° to 185° F), Without Damage
Storage Temperature
-40° to 100° C (-40° to 212° F)
Temperature Effect
±[0.02% URL + 0.06% of Span] per 20° C (36° F)
Ambient Temperature
-40° to 85° C (-40° to 185° F)
Humidity
0 to 100% Relative Humidity
Process Temperature
-40° to 100° C (-40° to 212° F)
Accuracy
For Ranges 1, 2, 3, 4, 5, or 6 and 316L Stainless Steel or Hastelloy diaphragm with silicon or haloCarbon filling fluid: 0.1 URL ≤ Span ≤ URL: ± 0.075% or Span. 0.025 URL ≤ Span < 0.1 URL: ± (0.0375+0.00375.URL/Span)% of Span. 0.0083 URL ≤ Span < 0.025 URL: ± (0.0015+0.00465.URL/Span)% of Span.
Span and Zero Adjustments
Non-interactive, via Digital Communication or Local Adjustment
Stability
Ranges 2, 3, 4, 5, and 6: ±0.15% of URL for 5 years at 20° C (68° F) TemperatureCchange and Up to 7 MPA (1,000 psi) of Static Pressure
Volumetric Displacement
>0.15 cm³ (0.01 in³)
Electromagnetic Interference Effect
Approved according to IEC61326-1:2006, IEC61326-2-3:2006, IEC61000-6-4:2006, IEC61000-6-2:2005
Process Connection - Threaded
1/4" NPT
1/2" NPT (With Adapter
Media
Gas
Liquids and Gases
Steam
Drain/Vent Position
Without Drain/Vent
Power Supply Effect
±0.005% of Calibrated Span Per Volt
Input Power
HART: 12-45 Vdc. Transient Suppressor Vmax = 65 Vp; Differential mode - bi-directional; Low current leak & capacitance; meets the standards: IEEE61000-4-4 & IEEE61000-4-5; Less than 5 nanosecond response time.
Electrical Connectors
1/2" NPT
Output
4-20 mA
HART: 2-wire, 4-20 mA according to NAMUR NE43 specification, with superimposed Digital Communication.
Turn-On Time
HART: Performs within Specifications in Less Than 5 Seconds After Power is Applied to the Transmitter
Display
4-1/2-Digit Numerical and 5-Character Alphanumerical LCD Indicator
Configuration
Software CONF401, DDCON100, or HPC301 and HPC401. Can Also be Configured Using DD and FDT/DTM tools, and Can be Partially Configured Through Local Adjustment
Control Functions Characteristics
HART: PID Control (PID) and Totalizer (TOT)
PID Configuration
With PID
Mounting
Carbon Steel Bracket and Accessories
Mounting Position Effect
Zero Shift of up to 250 Pa (1 inH₂O) Which Can be Calibrated Out. No Span Effect
Enclosure/Body Material
Aluminum - Injected
Enclosure Finish
Polyester (Gray Munsell N 6.5) Paint
Flange Material
Adapter and Drain/Vent: 316 Stainless Steel - CF8M (ASTM A351)