Images are representations only.

PD685 Intrinsically Safe IP67 Loop-Powered Meter

Brand: Precision Digital Corporation
The PD685 is an easy to use, loop-powered indicator, certified by CSA, ATEX and IECEx as intrinsically safe.

The PD685 carries international certifications under both the Class/Division System and Zone System, and is thereby suitable for use in gas and dust hazardous areas worldwide.

The PD685 can be seen from considerable distance in bright sunlight or dimly lit areas when the standard backlight feature is activated.

The fact that this meter is loop-powered means that there is no need to run additional, costly power lines into a hazardous area.

The meter gets all of the power it needs from the 4-20 mA loop and its 1 V - 4 V with backlight drop results in a minimal burden on the loop.

The meter features a wide -40 to 75°C operating temperature range and is available with a ½" conduit hole in a location of your choice for easy installation.

Calibration is a quick two-step process involving the adjustment of only two sets of coarse and fine, non-interacting potentiometers.
show more
The PD685 is an easy to use, loop-powered indicator, certified by CSA, ATEX and IECEx as intrinsically safe.

The PD685 carries international certifications under both the Class/Division System and Zone System, and is thereby suitable for use in gas and dust hazardous areas worldwide.

The PD685 can be seen from considerable distance in bright sunlight or dimly lit areas when the standard backlight feature is activated.

The fact that this meter is loop-powered means that there is no need to run additional, costly power lines into a hazardous area.

The meter gets all of the power it needs from the 4-20 mA loop and its 1 V - 4 V with backlight drop results in a minimal burden on the loop.

The meter features a wide -40 to 75°C operating temperature range and is available with a ½" conduit hole in a location of your choice for easy installation.

Calibration is a quick two-step process involving the adjustment of only two sets of coarse and fine, non-interacting potentiometers.

Specifications

Accuracy

  • ± 0.1 % of Full Scale ± 1 Count

Approvals & Certifications

  • ATEX
  • IECEx

Calibration

  • 4 mA Input: -1,000 to 1,000

Conduit Hole

  • One 1/2” Conduit Hole

Display

  • 3-1/2-Digit LCD

Electrical Connectors

  • Terminal Block for 12 to 22 AWG Wire

Enclosure, Body Material

  • Impact-Resistant Glass-Filled Polycarbonate

Environmental Protection

  • IP66
  • NEMA 4X / IP66

Humidity

  • 0 to 90 % Non-Condensing

Input

  • 4-20 mA

Operating Temperature

  • -40° to 85° C (-40° to 185° F)

Voltage Drop

  • 1 V at 20 mA