• Output: HART Protocol, 2-Wire 4-20mA
  • Input Range: -200°C to +1750°C, -328°F to +3182°F
    • Minimum Span: +10°C to +60°C, +50°F to +140°F 
  • Control: PID Capability
  • Power Supply: 
    • Bus Powered: 12 to 45 Vdc.
  • Digital Accuracy: ±0.2 to ±0.6 °C
  • Display: 4-1/2 digit numerical and 5-Character alphanumerical LCD indicator
  • Burnout: Upscale
  • Mounting Bracket: Carbon Steel or 316 Stainless Steel
  • Electrical Connection:
    • 1/2"-14 NPT
    • PG 13.5 DIN
    • M20 X 1.5
  • Damping Adjustment: User Configurable from 0 to 32 seconds
  • Power Supply Effect: ± 0.005% of calibrated span per volt
  • CSA Intrinsically Safe, Explosion Proof, Dust Ignition Proof, Non-Incendive
  • Order includes a SMAR Magnetic Screwdriver for adjustments if the LCD Display option is selected in the configuration below
The above description encapsulates the entire product series. Specifications for individual configurations may vary depending on the selection chosen.
read more...
TT301-0010-I3-PT4L3-BU
TT301-0010-I3-PT4L3-BU
$950.00
  • Display

    Not Required
  • Mounting

    None
  • Sensor Connection

    3-wire
  • Sensor Type

    RTD PT100 - IEC

Selected Configuration

Model #:

TT301-0010-I3-PT4L3-BU

Price:
$950.00 USD
Availability:
In Stock (25+)
Min. Qty:
1 Item

Configuration

reset configuration

Agency Approvals

  • CEPEL
  • CSA
  • EXAM
  • FM
  • NEMKO ATEX

Damping Adjustment

  • User Configurable from 0 to 32 Seconds (via Digital Communication).

Operating Temperature - Display

  • -20° to 80° C (-4° to 176° F)
  • -40° to 85° C (-40° to 185° F); without damage

Storage Temperature

  • -40° to 100° C (-40° to 212° F)

Temperature Effect

  • mV (-10-100 mV) TC (NBS: E, J, K ,N): ±0.03% of the input mV or 0.01 mV whichever is greater -10° C variation
  • mV (-6-22 mV), TC (NBS: B, R, S, T): ±0.03% of the input mV or 0.002 mV whichever is greater -10° C variation
  • Ohms: 0 to 400 Ohms, RTD (IEC: Pt100): ±0.03% of the input resistance or 0.04 Ohms, whichever is greater

Ambient Temperature

  • -40° to 85° C (-40° to 185° F)

Humidity

  • 0 to 100% Relative Humidity

Accuracy

  • ±0.02% of span

Span and Zero Adjustments

  • Non-interactive, via local Adjustment and Digital Communication.

Digital Stability

  • ±0.1% of Reading or +0.1° C (0.18° F), whichever is greater, for 1-year for thermocouples.
  • ±0.1% of Reading or +0.1° C (0.18° F), whichever is greater, for 2 -years for RTDs

Burn-Out

  • Upscale

Electromagnetic Interference Effect

  • Approved according to IEC61326-1:2006, IEC61326-2-3:2006, IEC61000-6-4:2006, IEC61000-6-2:2005

Sensor Connection

Available sensor connection types below, 3-wire is standard.
  • 2-wire
  • 3-wire
  • 4-wire
  • Backup
  • Differential

Power Supply Effect

  • ±0.005% of Calibrated Span Per Volt

Input Power

  • HART: 12-45 Vdc.

Communication

  • HART: 2-wire, 4-20 mA according to NAMUR NE43 specification, with super-imposed Digital Communication.

Electrical Connectors

  • 1/2" NPT

Output

  • 2-wire 4-20 mA

Display

Available display types below, no display is standard.
  • 4-1/2-Digit Numerical and 5-Character Alphanumerical LCD Indicator

Alarm

  • HART: In case of sensor or circuit failure, the self diagnostics drives the output to 3.6 to 21.0 mA, according to the user's choice & NAMUR NE43 specification.

Configuration

  • HART: By Digital Communication using the Configuration software CONF401, DDCON100, or HPC301 and HPC401. It can also be configured using DD and FDT/DTM tools, and can be partially configured through local Adjustment, since the transmitter is supplied with display.

Control Functions Characteristics

  • HART: PID Control, Alarm and Set Point Ramp Generator

Mounting

Available mounting types below, no mounting is standard.
  • 316 Stainless Steel Bracket and Accessories
  • Can be attached directly to the sensor. With an optional bracket can be installed on a 2" pipe or Fixed on a wall or panel.
  • Carbon Steel Bracket and Accessories

Enclosure/Body Material

  • 316 Stainless Steel IP/TYPE, 316 Stainless Steel for Saline Atmosphere IPW/TYPEX
  • Copper-Free Aluminum IPW/TYPEX, Aluminum for Saline Atmosphere IPW/TYPEX, Aluminum IP/TYPE

Enclosure Finish

  • Gray Munsell 6.5 Polyester Paint

Sensor/Probe Type

Available sensor types below, RTD PT100 - IEC is standard.
  • J Thermocouple
  • K Thermocouple
  • R Thermocouple
  • RTD PT100 - IEC
  • S Thermocouple
DDCON 100

DDCON 100

SMAR Universal HART Configurator Kit

HI321

HI321

SMAR HART Interface Cable, USB Type

HPC401 PLUS

HPC401 PLUS

SMAR HPC401 Plus HART/DDL Configurator

Magnetic Screwdriver

Magnetic Screwdriver

SMAR Magnetic Screwdriver, Magnetic Screwdriver