For Output Range 0 to 30 psig (0 to 2 bar, 0 to 200 kPa): 35 to 150 psig (2.4 to 10 bar, 240 to 1,000 kPa) to Extended
For Output Range 0 to 60 psig: 65 to 150 psig (4.6 to 10 bar, 460 to 1,000 kPa) to Extended
For Output Range 0 to 120 psig: 125 to 150 psig (8.8 to 10 bar, 880 to 1,000 kPa) to Extended
For Output Range 3 to 27 psig (0.2 to 1.8 bar, 20 to 180 kPa), 32 to 120 psig (2.2 to 8 bar, 220 to 800 kPa)
For Output Range psig: 3 to 15: psig: 20 to 120 (bar: 1.5 to 8, kPa: 150 to 800)
For Output Range psig: 6 to 30: psig: 35 to 120 (bar: 2.4 to 8, kPa: 240 to 800)
Supply Pressure Effect
Less than 0.1 psig (0.7 kPa, 0.007 bar) change for 10 psig (0.7 kPa, 0.007 bar) supply change - for extended range
No measurable effect
Output Pressure
psig: 0 to 120
psig: 0 to 30
psig: 0 to 60
psig: 3 to 15
psig: 3 to 27
psig: 6 to 30
Operating Temperature
-40° to 71° C (-40° to 160° F)
Storage Temperature
-40° to 82° C (-40° to 180° F)
Temperature Effect
+0.5% to +0.06% / ° F temperature change of span typical for extended range
Hysteresis
≤0.1% Full Scale
≤0.25% Full Scale to For Extended Range
Deadband, Approximate
≤0.02% Full Scale
Accuracy
0.15% Full Scale Typical ISA S51.1
0.25% Full Scale Guaranteed ISA S51.1
Repeatability
≤0.1% Full Scale
≤0.1% Full Scale for Extended Range
Span - Minimum
For Output Range 0 to 30 psig: 12.5 psig (0.85 bar, 85 kPa) to Extended Range
For Output Range 0 to 60 psig: 25 psig (1.5 bar, 50 kPa) to Extended Range
For Output Range 0 to 120 psig: 50 psig (3 bar, 300 kPa) to Extended Range
For Output Range psig: 3 to 15 - psig: 5 (bar: 0.35, kPa: 35)
For Output Range psig: 3 to 27 - psig: 10 (bar: 0.7, kPa: 70)
For Output Range psig: 6 to 30 - psig: 10 (bar: 0.7, kPa: 70)
Exhaust Capacity - Relieving Units Only
2 SCFM (3.4 m³/Hour)
Vibration Effect
<1% of span under the following conditions: 5 to 15 Hz at 0.8" constant displacement 15 to 500 Hz at 10g's - Extended
RFI/EMI Effect
<0.5% of Span at 30 V/m class 3 Band ABC (20-1,000 mHz) per SAMA PMC 33.1 1978 and <0.5% of Span at 10 V/m level, to 2 GHz Band per EN 61,000-4-3:1998 +A1 EMC Directive 89/336/EEC European Norms EN 61326
Process Connection - Threaded
1/4" Female BSPT
1/4" Female NPT
Relief
Relieving
Vent
Straight
Tapped Exhaust
Supply Voltage
3-wire voltage input: 7.2-30 Vdc, Less than 3 mA
Input
4-20 mA
mA DC: 4-20
Cable Length
100 feet (30 meters)
19.69 feet (6 meters)
50 feet (15.2 meters)
Signal Impedance
3-wire Voltage Input: 10 Kilohms
Operating Voltages
2-wire Current Input: 7.2 Vdc at 20 mA (4-20 mA Signal)
7.2 Vdc at 20 mA (4-20 mA signal)
Frequency
-3 db at 2 Hz per ISA S26.4.3.1 Load Configuration A - Extended Range
-3 db at 5 Hz per ISA S26.4.3.1 Load Configuration
Electrical Connectors
1/2" NPT
Reverse Polarity Protection
No damage occurs from reversal of normal Supply current (4-20 mA) or from misapplication of up to 60 mA
Flow Rate
11 SCFM (18.7 m³/Hour) at psig: 150 (bar: 10, kPa: 1,000) Supply and midscale Output - Extended Range
2.5 SCFM (4.25 m³/Hour) at psig: 25 (bar: 1.7, kPa: 170) Supply and psig: 9 (bar: 0.6, kPa: 60) Output
9 SCFM (15.3 m³/Hour) at psig: 120 (bar: 8, kPa: 800) Supply and psig: 9 (bar: 0.6, kPa: 60) Output
Air Consumption
Maximum: Set Point 0 psig: 0.5 SCFH (0.01 m³/hr) - For 0 to 120 psig Extended Range
Maximum: Set Point 0 psig: 1.6 SCFH (0.04 m³/hr) - For 0 to 60 psig Extended Range
Maximum: Set Point 0 psig: 3.1 SCFH (0.09 m³/hr) - For 0 to 30 psig Extended Range
Maximum: Set Point 3 psig: 3.5 SCFH (0.10 m³/hr)
Maximum: Set Point 9 psig: 7.0 SCFH (0.20 m³/hr)
Maximum: Set Point 15 psig: 4.7 SCFH (0.13 m³/hr) - For 0 to 60 psig Extended Range
Maximum: Set Point 15 psig: 7.8 SCFH (0.22 m³/hr) - For 0 to 30 psig Extended Range
Maximum: Set Point 15 psig: 9.5 SCFH (0.27 m³/hr)
Maximum: Set Point 30 psig: 3.8 SCFH (0.11 m³/hr) - For 0 to 120 psig Extended Range
Maximum: Set Point 30 psig: 7.8 SCFH (0.22 m³/hr) - For 0 to 60 psig Extended Range
Maximum: Set Point 30 psig: 11.8 SCFH (0.33 m³/hr) - For 0 to 30 psig Extended Range
Maximum: Set Point 30 psig: 13.5 SCFH (0.38 m³/hr)
Maximum: Set Point 60 : 7.6 SCFM (0.21 m³/hr) - For 0 to 120 psig Extended Range
Maximum: Set Point 60 psig: 13.3 SCFH (0.37 m³/hr) - For 0 to 60 psig Extended Range
Maximum: Set Point 120 psig: 15.1 SCFM (0.42 m³/hr) - For 0 to 120 psig Extended Range
Enclosure/Body Material
Chromate Treated Aluminum
Enclosure Finish
Epoxy Powder Coating
Orifice Material
Brass
Sapphire
Trim Material
Brass
Stainless Steel
Zinc-Plated Steel
Elastomers
Nitrile
Position Effect
0.125% at 90° and 0.25% at 180° - For Extended Range