Images are representations only.

RTDs with CIP Sanitary-Connected Well

Brand: Pyromation
The RTD sensors listed below are constructed with the CIP sanitary-connected cap thermowell, which is then mounted into the process with a clamp and mating sanitary cap.

A 3-wire spring-loaded RTD element and sheath is then screwed into the back of the thermowell.

This construction method allows for easy removal of both the well and/or the sensor assembly. The well and sanitary cap in contact with the process are all ground and polished to a finish that exceeds the 3-A Sanitary Standard 74.

Thermowells are supplied with a surface finish that meets or exceeds 32µin Ra.
show more
The RTD sensors listed below are constructed with the CIP sanitary-connected cap thermowell, which is then mounted into the process with a clamp and mating sanitary cap.

A 3-wire spring-loaded RTD element and sheath is then screwed into the back of the thermowell.

This construction method allows for easy removal of both the well and/or the sensor assembly. The well and sanitary cap in contact with the process are all ground and polished to a finish that exceeds the 3-A Sanitary Standard 74.

Thermowells are supplied with a surface finish that meets or exceeds 32µin Ra.

Specifications

Brand

Element Connection

  • 3-Wire
  • 4-Wire

Bore Size

  • 0.260”

Process Connection

  • 1-1/2” Tri-Clamp
  • 1” Tri-Clamp
  • 2” Tri-Clamp
  • 3” Tri-Clamp
  • 2-1/2” Tri-Clamp

Well Material

  • 316 Stainless Steel

Head Material

  • 316L Stainless Steel
  • Aluminum
  • Polypropylene