L1102 (COB) Explosion-Proof LED Light

Brand: Top Hi-Tech Inc.
  • Volt.: 24 V / 110 V / 120 V / 208 V / 220 V / 277 V / 480 V AC
  • Watt.: 60 W / 80 W / 100 W
  • Amps: 60 W (0.13 ~ 2.5 A) / 80 W (0.17 ~ 3.33 A) / 100 W (0.21 ~ 4.17 A)
  • Frequency: 50 Hz / 60 Hz
  • Power Factor: cos ≧ 0.9 / cos ≧ 0.87 (480 V)
Ambient temperature:

  • -20° C ~ +40° C, T5
  • CID1: -40° C ~ +40° C, T5 / CID2: +40° C, T4 / CIID1: +40° C, T5 (UL Certification)
Degree of Protection - IP68 / NEMA 6P 
IECEx Certification
  • Ex db IIC T5 Gb
  • Ex tb IIIC T95˚C Db 
ATEX Certification
  • II 2 G Ex db IIC T5 Gb
  • II 2 D Ex tb IIIC T95˚C Db 
UL Certification
  • UL844 - Class I, Division 1 (Group B, C and D) / Class I, Division 2 (Groups A, B, C and D) / Class II, Division 1 (Group E, F and G) / Class III
  • UL60079 - Zone 1, AEx d IIB+H2 / Zone 21, AEx tb IIIC
  • UL1598 
CML Certification
  • Ex d IIC T5 Gb
  • Ex tb IIIC T95˚C Db 
ABS & CR Certification
  • II 2 G Ex d IIB + H2 T5...T4 Gb
  • II 2 D Ex tb IIIC T110˚C Db 
TS Certification
  • Ex d IIC T5 Gb
  • Ex tb IIIC T100˚C Db 
GB Certification
  • Ex d IIC T5 Gb
  • Ex tD A21 T95˚C 
KC Certification
  • Ex db IIC T5 Gb
  • Ex tb IIIC T95˚C Db
Features
  • High efficacy
  • Heat Resistance 85° C to 100° C
  • Salt Spray 1000 hrs passed
  • Retrofit to conventional explosion-proof light
 Applicable Location
  • Zone 1 & Zone 2
  • Zone 21 & Zone 22
  • Class I, Division 1 (Group B, C and D)
  • Class I, Division 2 (Groups A, B, C and D)
  • Class II, Division 1 (Group E, F and G)
  • Class III
show more
Images are representations only.
  • Volt.: 24 V / 110 V / 120 V / 208 V / 220 V / 277 V / 480 V AC
  • Watt.: 60 W / 80 W / 100 W
  • Amps: 60 W (0.13 ~ 2.5 A) / 80 W (0.17 ~ 3.33 A) / 100 W (0.21 ~ 4.17 A)
  • Frequency: 50 Hz / 60 Hz
  • Power Factor: cos ≧ 0.9 / cos ≧ 0.87 (480 V)
Ambient temperature:

  • -20° C ~ +40° C, T5
  • CID1: -40° C ~ +40° C, T5 / CID2: +40° C, T4 / CIID1: +40° C, T5 (UL Certification)
Degree of Protection - IP68 / NEMA 6P 
IECEx Certification
  • Ex db IIC T5 Gb
  • Ex tb IIIC T95˚C Db 
ATEX Certification
  • II 2 G Ex db IIC T5 Gb
  • II 2 D Ex tb IIIC T95˚C Db 
UL Certification
  • UL844 - Class I, Division 1 (Group B, C and D) / Class I, Division 2 (Groups A, B, C and D) / Class II, Division 1 (Group E, F and G) / Class III
  • UL60079 - Zone 1, AEx d IIB+H2 / Zone 21, AEx tb IIIC
  • UL1598 
CML Certification
  • Ex d IIC T5 Gb
  • Ex tb IIIC T95˚C Db 
ABS & CR Certification
  • II 2 G Ex d IIB + H2 T5...T4 Gb
  • II 2 D Ex tb IIIC T110˚C Db 
TS Certification
  • Ex d IIC T5 Gb
  • Ex tb IIIC T100˚C Db 
GB Certification
  • Ex d IIC T5 Gb
  • Ex tD A21 T95˚C 
KC Certification
  • Ex db IIC T5 Gb
  • Ex tb IIIC T95˚C Db
Features
  • High efficacy
  • Heat Resistance 85° C to 100° C
  • Salt Spray 1000 hrs passed
  • Retrofit to conventional explosion-proof light
 Applicable Location
  • Zone 1 & Zone 2
  • Zone 21 & Zone 22
  • Class I, Division 1 (Group B, C and D)
  • Class I, Division 2 (Groups A, B, C and D)
  • Class II, Division 1 (Group E, F and G)
  • Class III

Review this product and let us know your experiences

Write a Review

Ask a Question

Write a Question