Images are representations only.
Description
Wherever the process pressure has to be indicated locally and, at the same time, a signal transmission to the central control or remote centre is desired, the model PGT43HP intelliGAUGE® (patent, property right: e.g. DE 202007019025) can be used.
Due to the metallic pressure element limit stop, these instruments have a high overload safety in the ranges of 40, 100 and 400 bar.
Features- No configuration necessary due to "Plug-and-Play".
- Measuring ranges from 0 ... 16 mbar.
- Wide choice of special materials.
- For gaseous, liquid and aggressive media, also in aggressive ambience, due to all stainless steel construction.
- Safety pressure gauge S3 per EN 837.
Specifications
Specifications
Brand
Nominal Size in mm
- 100
- 160
Accuracy Class
- 1.0
- 1.6
Scale Ranges
- or all other equivalent vacuum or combined pressure and vacuum ranges
- other units (e.g. psi, kPa) available
- 0 to 400 mbar to 0 to 40 bar (flange Ø 100 mm)
- 0 to 16 mbar to 0 to 250 mbar (flange Ø 160 mm)
Scale
- Dual scale
- Single scale
Pressure Limitation
- Fluctuating: 0.9 x full scale value
- Steady: Full scale value
Overload Safety
- Vacuum safety to -1 bar
- 100 bar
- 40 bar
- 400 bar (only for scale ranges ≥ 0 ... 400 mbar 3))
Process Connection with Lower Measuring Flange
- and other threaded connections and open connecting flanges per EN/ASME from DN 15 to DN 80 (see data sheet IN 00.10)
- Open connecting flange 2" class 300, RF per ASME B16.5
- Open connecting flange 1" class 300, RF per ASME B16.5
- Open connecting flange DN 50 PN 40 per EN 1092-1, form B
- Open connecting flange DN 25 PN 40 per EN 1092-1, form B
- 1/2" NPT Female
- 1/2" NPT
- G ½ B
Permissible Temperature
- Ambient: -20 ... +60° C [-4 ... +140° F]
- Medium: +200° C [+392° F] maximum
- Medium: +100° C [+212° F] maximum
Temperature Effect
- When the temperature of the measuring system deviates from the reference temperature (+20° C): max. ±0.8 %/10 K of Full Scale Value
Case
- Safety version S3 per EN 837: With solid baffle wall (Solidfront) and blow-out back Instruments with liquid filling with compensating valve to vent case
Case Filling
- Without
- With silicone oil M50 case filling, ingress protection IP65
Applications
Typical Applications
- Acquisition and display of processes
- Output signals 4 ... 20 mA, 0 ... 20 mA, 0 ... 10 V for the transmission of process values to the control room
- For measuring points with increased overload of 40, 100 or 400 bar
- Easy-to-read, analogue on-site display needing no external power
- Safety-related applications