Universal load cell combining high accuracy, sturdiness and easiness to install.

Features:
  • Wide range of capacities: 100 N (10 kg) to 1000 N (100 kg)
  • Overload protection in tension and compression (not for 2712-5 kN and 2712-10 kN)
  • Easy to install, compact design
  • Protection IP 54 / IP 65
  • Material: anodized aluminium alloy
  • Available options (non exhaustive list):
    • High service temperature (150° C)
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Cable output by connector
  • Also available as standard reference load cells following ISO 376
read more...

Agency Approvals

  • ATEX Intrinsic Safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
  • CE

Environmental Protection

  • IP54
  • IP65

Operating Temperature

  • 150° C (302° F)

Storage Temperature

  • -50 to 85° C (-58° to 185° F)

Accuracy

  • 0.02% of Full Scale
  • 0.03% of Full Scale
  • 0.1% of Full Scale

Sensitivity

  • Tolerance: <±0.3% (Class 0.1) to <±0.05% (Class 0.02)

Zero Balance

  • ±0.02 mV/V

Repeatability

  • Error: <±0.03% of Full Scale (Class 0.1) to <±0.01% of Full Scale (Class 0.02)

Resistance

  • Input/Output: 352 ±2 Ohms

Cable Length

  • 10 feet (3 meters)

Insulation Resistance

  • >5,000 MegaOhms

Load Limit

  • 120% of Full Scale

Electrical Connectors

  • Cable

Excitation Voltage

  • 10 Vdc
  • 3-12 Vdc - Nominal Range

Enclosure/Body Material

  • Anodized Aluminum

Applications

  • Conveyors
  • Hoppers
  • Measurement
  • Reactors

Linearity

  • Error: <±0.1% of Full Scale (Class 0.1) to <±0.015% of Full Scale (Class 0.02)

Service Temperature

  • -30 to 70° C (-22° to 158° F)

Static Lateral Force

  • 50% of Full Scale

Temperature Coefficient

  • <±0.008% to <±0.05% of Full Scale/10° C (18° F)