The Kayden CLASSIC 832 Flow Switch & Transmitter features a precision welded, highly accurate stainless steel sensor.

Ideal for liquids, gases & slurries in a clean or dirty process.

The CLASSIC 832 is available with a Raised Face or RTJ Flange, in a wide range of flange sizes, ANSI ratings and assembly widths.

All Kayden models feature a rugged flameproof enclosure with blind or lens covers available.

Kayden’s advanced digital electronics will revolutionize the way you monitor and control your process.

  • Process Connections

    • Raised Face or RTJ Flange
  • Adjustable Set Point Range

    • 0-20,000 cc/s
  • Sensor Assembly Body Width

    • Available in 1/2" (1 cm) Increments
    • Min. 7" - Max. 72" (18 cm to 182 cm).  (Minimum width varies with Flange Size and Rating)
  • Input Power

    • 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum)

    • 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor)

    • -45°C to 200°C, -50°F to 392°F
  • Local Enclosure

    • Aluminum Flameproof, 1" FNPT Conduit Connection
  • Cover

    • Blind or Glass Lens, Flameproof
  • Wetted Materials

    • 316/316L Stainless Steel with Nickel Braze
  • Outputs/Communications

    • Two Independent Relays (SPDT), 4-20 mA, Modbus
  • Approvals

    • UL
    • FM
    • CSA
    • Single Seal
    • NACE
    • NEMA 4X
The above description encapsulates the entire product series. Specifications for individual configurations may vary depending on the selection chosen.
read more...

Showing 6 Models
Showing 6 Models

6 Models In Stock

832-RA3A111A-I0070-AH0C1G0A1E
832-RA3A111A-I0070-AH0C1G0A1E
$1,844.50
  • Raised Face Flange (A)
  • 3/4" 150# (111)
  • Sch40 (0)
  • Local Enclosure Cover: Glass (G)
  • Remote Enclosure Cover: None (0A)
  • CSA (1)
  • Sensor Material

    316/316L Stainless Steel, Nickel Brazed
  • Process Connection Flange Type

    Raised Face
  • Flange Size & ANSI Rating

    3/4" 150#
  • Flange Material

    316/316L Stainless Steel
  • Bleed Port

    1/4" Threaded
  • Sensor Orientation

    Horizontal
  • Pipe Schedule

    Schedule 40
  • Cover for Local Enclosure

    Glass Lens Cover
  • Remote Electronics Enclosure & Cover

    Not Required
  • Agency Approvals

    CSA (Canada & US)
832-RA3A121A-I0070-AH0C1G0A5E
832-RA3A121A-I0070-AH0C1G0A5E
$1,844.50
832-RA3A121A-I0070-AV0C1G0A9E
832-RA3A121A-I0070-AV0C1G0A9E
$1,844.50
  • Raised Face Flange (A)
  • 1" 150# (121)
  • Sch40 (0)
  • Local Enclosure Cover: Glass (G)
  • Remote Enclosure Cover: None (0A)
  • FM (9)
  • Sensor Material

    316/316L Stainless Steel, Nickel Brazed
  • Process Connection Flange Type

    Raised Face
  • Flange Size & ANSI Rating

    1" 150#
  • Flange Material

    316/316L Stainless Steel
  • Bleed Port

    1/4" Threaded
  • Sensor Orientation

    Vertical
  • Pipe Schedule

    Schedule 40
  • Cover for Local Enclosure

    Glass Lens Cover
  • Remote Electronics Enclosure & Cover

    Not Required
  • Agency Approvals

    FM
832-RA3A131A-I0110-AH0C1G0A9E
832-RA3A131A-I0110-AH0C1G0A9E
$1,844.50
  • Raised Face Flange (A)
  • 1-1/2" 150# (131)
  • Sch40 (0)
  • Local Enclosure Cover: Glass (G)
  • Remote Enclosure Cover: None (0A)
  • FM (9)
  • Sensor Material

    316/316L Stainless Steel, Nickel Brazed
  • Process Connection Flange Type

    Raised Face
  • Flange Size & ANSI Rating

    1-1/2" 150#
  • Flange Material

    316/316L Stainless Steel
  • Bleed Port

    1/4" Threaded
  • Sensor Orientation

    Horizontal
  • Pipe Schedule

    Schedule 40
  • Cover for Local Enclosure

    Glass Lens Cover
  • Remote Electronics Enclosure & Cover

    Not Required
  • Agency Approvals

    FM
832-RA3A141A-I0070-AV0C1G0A5E
832-RA3A141A-I0070-AV0C1G0A5E
$1,844.50
6
832-RA3A141A-I0090-AV0C1G0A9E
832-RA3A141A-I0090-AV0C1G0A9E
$2,134.00
  • Process Connection: Flanged Raised Face, 2" 150# Vertical
  • Adjustable Set Point Range: 0-20,000 cc/s
  • Sensor Assembly Body Length: 9", 22.8cm
  • Process Connection: 3/4" MNPT
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -50°F to 392°F
  • Local Enclosure: Aluminum Flameproof, 1" FNPT Conduit Connection
  • Cover: Flameproof Glass Lens
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • 316 Stainless Steel with Nickel Braze
  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus
  • FM, NACE, NEMA 4

Selected Configuration

Model #:

832RA3A142AI0115AV1C1B0A1E

Price:
$2,438.00 USD
Availability:
Ships 10 - 15 Days
Min. Qty:
1 Item

Configuration

reset configuration

Agency Approvals

  • CRN - Canadian Registration Number - The Kayden Classic 832 does not have a CRN Number


  • CSA - Local (Sensor) Enclosure
    • Flameproof: Class I, Division 1, Groups B, C and D; Ex d IIB + H2
    • AEx d IIB + H2 (Class I, Zone 1, Group IIB + H2)
    • Temperature Code: T3
    • Enclosure Type 4 / IP55
    • Single Seal Approved per ANSI / ISA 12.27.01-2003
  • CSA - Remote Electronics Enclosure - Optional
    • Flameproof: Class I, Groups B, C and D; Ex d IIB + H2
    • AEx d IIB + H2 (Class I, Zone 1, Groups IIB + H2)
    • Temperature Code: T3
  • FM - Local (Sensor) Enclosure
    • Flameproof: Class I, Division 1, Groups B, C and D
    • Temperature Codes: T2D (Ta=75º C); T3 (Ta=65º C)
    • Class I, Zone 1, AEx d IIB + H2
    • Enclosure Type 4 / IP55
  • FM - Remote Electronics Enclosure - Optional
    • Flameproof: Class I, Division 1, Groups B, C and D
    • Temperature Codes: T2D (Ta=75º C), T3 (Ta=65º C)
    • Class I, Zone 1, AEx d IIB + H2
    • Enclosure Type 4 / IP55
  • UL

Principle of Operation

  • Thermal (Calorimetric)

Environmental Protection

  • NEMA 4 / IP55

Operating Pressure - Sensor

  • Maximum Working Pressure:
    • Class 150 (275 psi, 1896 kPa, 18.9 bar)*
    • Class 300 (720 psi, 4964 kPa, 49.6 bar)*
    • Class 600 (1440 psi, 9928 kPa, 99.2)*

Sensor Orientation

  • Horizontal
  • Vertical

Operating Temperature - Electronics

For temperatures above +65° C (+149° F), the electronics must be remotely mounted.
  • -55° to 65° C (-67° to 149° F)

Operating Temperature - Sensor

  • -45° to 200° C (-50° to 392° F)

Storage Temperature

  • Product should be stored in a clean and dry environment between -30° and 60° C (-22° and 140° F)

Accuracy

  • Flow Service:
    ±1.0% of Set Point Velocity over Operating Range of ±28º C (±50º F)
  • Level Service:
    ±0.64 cm (0.25")

Switch Point Range

  • Gases:
    0.6 to 20,000 cc/second, standard condition: 21° C (70° F) at 14.7 psi (1 atm)
  • Hydrocarbon-based Liquids:
    0.033 to 110 cc/second
  • Water-based Liquids:
    0.015 to 50 cc/second

Response Time

  • Approximately 0.5 to 30 Seconds

Process Connection - Flanged

3/4" is standard.
  • 4" (DN100) - 150#
  • 4" (DN100) - 300#
  • 4" (DN100) - 600#
  • 4" (DN100) - 900#
  • 4" (DN100) - 1500#
  • 10" (DN250) - 150#
  • 10" (DN250) - 300#
  • 10" (DN250) - 600#
  • 10" (DN250) - 900#
  • 10" (DN250) - 1500#
  • 6" (DN150) - 150#
  • 6" (DN150) - 300#
  • 6" (DN150) - 600#
  • 6" (DN150) - 900#
  • 6" (DN150) - 1500#
  • 2" (DN50) - 150#
  • 2" (DN50) - 300#
  • 2" (DN50) - 600#
  • 2" (DN50) - 900#
  • 2" (DN50) - 1500#
  • 1-1/2" (DN40) - 150#
  • 1-1/2" (DN40) - 300#
  • 1-1/2" (DN40) - 600#
  • 1-1/2" (DN40) - 900#
  • 1-1/2" (DN40) - 1500#
  • 8" (DN200) - 150#
  • 8" (DN200) - 300#
  • 8" (DN200) - 600#
  • 8" (DN200) - 900#
  • 8" (DN200) - 1500#
  • 3" (DN80) - 150#
  • 3" (DN80) - 300#
  • 3" (DN80) - 600#
  • 3" (DN80) - 900#
  • 3" (DN80) - 1500#
  • 3/4" (DN20) - 150#
  • 3/4" (DN20) - 300#
  • 3/4" (DN20) - 600#
  • 3/4" (DN20) - 900#
  • 3/4" (DN20) - 1500#
  • 1" (DN25) - 150#
  • 1" (DN25) - 300#
  • 1" (DN25) - 600#
  • 1" (DN25) - 900#
  • 1" (DN25) - 1500#
  • 5" (DN125) - 150#
  • 5" (DN125) - 300#
  • 5" (DN125) - 600#
  • 5" (DN125) - 900#

Pipe Schedule

Schedule 40 is standard.
  • Schedule 40
  • Schedule 80

Flange Type

Raised face is standard.
  • Raised Face
  • RTJ - Ring Type Joint

Bleed Port

  • 1/4" Threaded

Sensor Assembly Body Lengths

  • Custom Body Lengths: 7" to 72" (18 cm to 182 cm) in 1/2" (1 cm) Increments

Switch Type

  • 2 SPDT sealed relay contacts rated @ 4 amps resistive 230 VAC or 30 VDC Max, individually adjustable

Input Power

  • 12-24 Vdc; 115-230 Vac, 50-60 Hz / Universal Power Input
  • Power Consumption: Maximum 4.8 W (Fully Configured)

Communication

  • MODBUS RTU Communication-Alarms, Flow Status and Diagnostics
  • RS-485 using Kayden's Remote Control and Monitoring Software (RCMS) or other Modbus Compatible Software

Remote Control and Monitoring Software

  • Adjust Relay Modes
  • Adjust Set Points 1 and 2
  • Load or Save User Settings
  • Lock or Unlock the Display Panel to Protect the Settings
  • Many other Adjustable Features
  • Modify Heater Settings to Optimize Response Time
  • Monitor Operating Status
  • Operated via a Personal Computer Locally or from a Remote Control Center
  • Visualize the Actions of the Process via the Graphical Display

Electronics - Standard Features

  • * Only configurable from the Kayden RCM software
  • 100% Digital Design. Electronics are Environmentally Sealed
  • 4-Adjustable Independent Switch Point Timers
  • Automated Redundant Self-Test Diagnostics
  • Display Panel Lock-Out*
  • Easy Setup: No Mechanical Jumpers or Trim Pots
  • Incrementally Adjustable Heater Power (5% steps) with Automatic Over-Range Protection
  • Intelligent User Interface with Push-Button and Constant Display of Operation (Flow/Level)
  • Start-Up Bypass Timer
  • Temperature Compensation
  • Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode

Enclosure/Body Material

  • Copper-Free Aluminum (Does not exceed 0.4% Copper)

Enclosure Finish

  • Powder Coated Polyester TGIC

Enclosure/Body Details

  • 1" Female NPT Conduit Connection
  • Buna-N O-Ring on Cover

Flange Material

  • 316/316L Stainless Steel

Remote Electronics Enclosure and Cover

For temperatures above +65° C (+149° F), the electronics must be remotely mounted. If cables are required, we recommend the Kayden A06-XP Flameproof Cable & Connector Assembly.

These covers are acceptable for use in hazardous areas.
  • Blind Cover - Flameproof
  • Glass Lens Cover - Flameproof

Wetted Materials

  • 316/316L Stainless Steel with Nickel Brazing

Cover - For Local Enclosure

For local enclosure types below, blind cover is standard.
  • Blind Cover - Flameproof
  • Glass Lens Cover - Flameproof

Sensor/Probe Style

  • InLine

Applications

  • Flow
A05-GP

A05-GP

Kayden General Purpose Remote Cable

A06-GP

A06-GP

Kayden General Purpose Cable & Connector Assembly

A06-XP

A06-XP

Kayden Flameproof Cable & Connector Assembly

A15-321

A15-321

Kayden RS232/RS485 Serial Communication Adapter

A15-322

A15-322

Kayden RS232/USB Adapter

A15-323

A15-323

Kayden RS485/USB Adapter

Flat Duct Flange

Flat Duct Flange

Kayden Flat Duct Flange Mounting Plate

Rolled Duct Flange

Rolled Duct Flange

Kayden Rolled Duct Flange Mounting Plate