Small sized single point load cell.

Features:
  • Designed for off-center load
  • Maximum platform size: 250 x 250/400 x 400 mm (according to capacity)
  • Small sized
  • Material: anodized aluminium alloy
  • Protection: IP 54 
  • Easy to install
  • Available options (non exhaustive list) :     
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
read more...

Agency Approvals

  • ATEX Intrinsic Safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80°C Da
  • CE

Storage Temperature

  • -50 to 85° C (-58° to 185° F)

Sensitivity

  • Sensitivity Tolerance: <±0.2%

Accuracy

  • 0.03% of Full Scale
  • 3,000 d Except Thermal Drifts

Zero Balance

  • ±0.02 mV/V

Repeatability

  • Repeatability Error: <±0.015% of Full Scale

Environmental Protection

  • IP54
  • IP63

Resistance

  • Input/Output: 352 ±2 Ohms

Cable Length

  • 1.64 feet (0.5 meter)
  • 5 feet (1.5 meters)

Insulation Resistance

  • >5,000 MegaOhms

Load Limit

  • 150% of Full Scale

Enclosure/Body Material

  • Anodized Aluminum

Applications

  • Batching System
  • Bench Scales
  • Hoppers

Linearity

  • Error: <±0.025% of Full Scale

Service Temperature

  • -30 to 70° C (-22° to 158° F)

Capacity

  • 3 to 200 kg

Temperature Coefficient

  • <±0.05% of Full Scale/10° C (18° F)
  • <±0.015% of Full Scale/10° C (18° F)
  • <±0.023% of Full Scale/10° C (18° F)
  • <±0.1% of Full Scale/10° C (18° F)