• ProVu Dual-Line Process Meter
  • Display: 
    • Upper: 0.60" (14mm) 6 Digit Red LED
    • Lower: 0.46" (12mm) 6 Digit Red LED
  • Performance:
    • Signal input conditioning for flow & round
    • Multi-pump alternation control
  • Inputs:
    • Field Selectable Analog
    • 0-20 mA
    • 4-20 mA
    • ±10 VDC (0-5, 1-5, 0-10 V)
    • Modbus PV (Slave)
  • Output: 2 or 4 Relays  and/or 4-20 mA Output
  • Power Supply: 85-265 VAC or 12/24 VDC
  • Connections:
    • Screw Terminal Blocks
    • 12 to 22 AWG
    • RJ45
    • Digital I/O
    • Serial Communication Adapter
  • Communication Options:
    • I/O
    • Relay Expansion
    • Modbus Communication Modules
  • Operating Temperature: -40°C to +65°C (-40°F to + 149°F)
  • Enclosure Materials: Black high-impact plastic
  • Mounting: 
    • 1/8 DIN Panel cutout required 3.622" x 1.772" (92mm x 45mm)
    • Two panel mounting bracket assemblies are provided
  • Environmental Protection:
    • NEMA 4X
    • IP65
  • Agency Approvals: 
    • CE
    • c-UL
The above description encapsulates the entire product series. Specifications for individual configurations may vary depending on the selection chosen.
read more...

Selected Configuration

Model #:

PD6000-6R0

Price:
$329.00 USD
Availability:
Ships 2 - 4 Weeks
Min. Qty:
1 Item

Configuration

reset configuration

Agency Approvals

  • UL

Calibration

  • +10 Volts: Minimum Span Input 1 and 2: 0.10 Volts
  • 4-20 mA: Minimum Span Input 1 and Input 2: 0.15 mA

Operating Temperature

  • -40° to 65° C (-40° to 150° F)

Humidity

  • 0 to 90% Non-Condensing

Deadband

  • 0 to 100% of Span
  • User Programmable

Environmental Protection

  • NEMA 4X / IP66

Switch Type

  • SPDT

Supply Voltage

  • 18-28 Vdc
  • 90-265 Vdc

Communication

  • Serial Communication Adapters

Electrical Connectors

  • Digital I/O
  • Removable Terminal Block Accepts 12 to 22 AWG Wire
  • RJ45 for External Relays

Rating

  • 2 or 4 SPDT Internal and/or 4 SPST external Relays

Relay Operation

  • Automatic (Non-Latching)
  • Latching (Requires Manual Acknowledge)
  • Off (Disable Unused Relays and Enable Interlock Feature, Manual On/Off Control Mode)
  • Pump Alternation Control (2 to 8 Relays)
  • Sampling (Based on Time)

Output

  • 4-20 mA

Isolation

  • 4 kV Input/Output-to-power-line
  • 500 V input to Output or Output to P+ Supply

Display

  • Red LEDs
  • Upper: 0.60" High, Lower: 0.46" High

Alarm

  • Unused Alarm LEDs and Relays May Be Disabled
  • User May Program Any Alarm for High or Low Trip Point

Programming

  • Cloning Using Copy Function
  • Digital Inputs
  • Four Front Panel Buttons
  • Modbus Registers
  • PC and MeterView Pro Software

Mounting

  • 1/8" DIN panel cut-out required. Two panel mounting brackets included.