Images are representations only.

604TU Series Temperature Switch

Brand: Custom Control Sensors, LLC
Does not ship to OH, United States
The 604TU Series is a general purpose temperature switch with a stainless steel capillary tube and armored jacket probe port fitting.

It is constructed with an integral terminal box and switch design and easy set point adjustment.

It is also easily mounted to bulkheads and UL certified with NEMA 4 and IP65 rating. It has high vibration and shock resistance utilizing Dual Snap® disc spring technology.
Features
  • Adjustable Set Point Range
    • Increasing
      • -30° to 630° F
      • -34° to 332° C
    • Decreasing
      • -39° to 624° F
      • -39° to 329° C
  • Deadband - Approximate
    • At Bottom of Range: 9° to 24° F, 5° to 13° C
    • At Top of Range: 3° to 6° F, 2° to 8° C
  • Probe Temperature - Maximum: 200° to 650° F, 93° to 343° C
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel & Graphite
    • Capillary Tube: Lubricated Glass Fiber
  • Relay: SPDT or DPDT
  • UL, CE Mark, General Purpose
The 604TU Series is a general purpose temperature switch with a stainless steel capillary tube and armored jacket probe port fitting.

It is constructed with an integral terminal box and switch design and easy set point adjustment.

It is also easily mounted to bulkheads and UL certified with NEMA 4 and IP65 rating. It has high vibration and shock resistance utilizing Dual Snap® disc spring technology.
Features
  • Adjustable Set Point Range
    • Increasing
      • -30° to 630° F
      • -34° to 332° C
    • Decreasing
      • -39° to 624° F
      • -39° to 329° C
  • Deadband - Approximate
    • At Bottom of Range: 9° to 24° F, 5° to 13° C
    • At Top of Range: 3° to 6° F, 2° to 8° C
  • Probe Temperature - Maximum: 200° to 650° F, 93° to 343° C
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel & Graphite
    • Capillary Tube: Lubricated Glass Fiber
  • Relay: SPDT or DPDT
  • UL, CE Mark, General Purpose
Models matching criteria: 20
CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 5` Capillary, DPDT show more
  • Adjustable Set Point Range:
    • Increasing: +35°F to +140°F, +2°C to +60°C
    • Decreasing: +21°F to +135°F, -6°C to +57°C
    • Deadband: Approximately
      • At Bottom of Range: 14°F, 4°C
      • At Top of Range: 5°F, 3°C
    • Probe Temperature (Maximum): +300°F, +149°C
    • Wetted Materials:
      • Temperature Probe: 300 Stainless Steel & Graphite
      • Capillary Tube: Lubricated Glass Fiber
      • Relay: DPDT
    • UL, CE Mark, NACE, General Purpose
    5 - 7 weeks
    Non-Cancellable / Non-Refundable
    $1,372.52 USD
    Does not ship to OH, United States
    CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 5` Capillary, DPDT show more
    • Adjustable Set Point Range:
      • Increasing: +90°F to +210°F, +32°C to +99°C
      • Decreasing: +75°F to +205°F, +24°C to +96°C

    • Deadband: Approximately
      • At Bottom of Range: 15°F, 8°C
      • At Top of Range: 5°F, 3°C

    • Probe Temperature (Maximum): +300°F, +149°C
    • Wetted Materials:
      • Temperature Probe: 300 Stainless Steel & Graphite
      • Capillary Tube: Lubricated Glass Fiber
      • Relay: DPDT

    • UL, CE Mark, NACE, General Purpose
    5 - 6 weeks
    Non-Cancellable / Non-Refundable
    $1,372.52 USD
    Does not ship to OH, United States
    CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 5` Capillary show more
    • Adjustable Set Point Range:
      • Increasing: +35°F to +140°F, +2°C to +60°C
      • Decreasing: +21°F to +135°F, -6°C to +57°C
      • Deadband: Approximately
        • At Bottom of Range: 14°F, 4°C
        • At Top of Range: 5°F, 3°C
      • Probe Temperature (Maximum): +300°F, 149°C
      • Wetted Materials:
        • Temperature Probe: 300 Stainless Steel & Graphite
        • Capillary Tube: Lubricated Glass Fiber
      • Relay: SPDT
      • UL, CE Mark, NACE, General Purpose
      5 - 7 weeks
      $2,586.50 USD
      Does not ship to OH, United States
      CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 5` Capillary show more
      • Adjustable Set Point Range:
        • Increasing: +90°F to +210°F, +32°C to +99°C
        • Decreasing: +75°F to +195°F, +27°C to +91°C
        • Deadband: Approximately
          • At Bottom of Range: 15°F, 5°C
          • At Top of Range: 5°F, 8°C
        • Probe Temperature (Maximum): +300°F, +149°C
        • Wetted Materials:
          • Temperature Probe: 300 Stainless Steel & Graphite
          • Capillary Tube: Lubricated Glass Fiber
        • Relay: SPDT
        • UL, CE Mark, NACE, General Purpose
        5 - 7 weeks
        $2,640.81 USD
        Does not ship to OH, United States
        CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 15` Capillary show more
        • Adjustable Set Point Range:

          • Increasing: +35°F to +140°F, +2°C to +60°C
          • Decreasing: +21°F to +135°F, -6°C to +57°C



        • Deadband: Approximately

          • At Bottom of Range: 14°F, 4°C
          • At Top of Range: 5°F, 3°C

        • Probe Temperature (Maximum): +300°F, +149°C
        • Wetted Materials:
          • Temperature Probe: 300 Stainless Steel & Graphite
          • Capillary Tube: Lubricated Glass Fiber

        • Relay: SPDT
        • Contacts: Gold
        • UL, CE Mark, NACE, General Purpose
        13 - 14 weeks
        $2,718.61 USD
        Does not ship to OH, United States
        CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 25` Capillary show more
        • Adjustable Set Point Range:

          • Increasing: +90°F to +210°F, +32°C to +99°C
          • Decreasing: +75°F to +195°F, +27°C to +91°C


          • Deadband: Approximately
            • At Bottom of Range: 15°F, 5°C
            • At Top of Range: 5°F, 8°C

          • Probe Temperature (Maximum): +300°F, +149°C
          • Wetted Materials:
            • Temperature Probe: 300 Stainless Steel & Graphite
            • Capillary Tube: Lubricated Glass Fiber

          • Relay: SPDT
          • UL, CE Mark, NACE, General Purpose
          13 - 14 weeks
          $2,786.14 USD
          Does not ship to OH, United States
          CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 5` Capillary show more
          • Adjustable Set Point Range:

            • Increasing: -30°F to +55°F, -34°C to +13°C
            • Decreasing: -39°F to +52°F, -39°C to +11°C


            • Deadband: Approximately
              • At Bottom of Range: 9°F, 5°C
              • At Top of Range: 3°F, 2°C

            • Probe Temperature (Maximum): +200°F, +121°C
            • Wetted Materials:
              • Temperature Probe: 300 Stainless Steel & Graphite
              • Capillary Tube: Lubricated Glass Fiber

            • Relay: SPDT
            • UL, CE Mark, NACE, General Purpose
            Contact For Inventory
            Does not ship to OH, United States
            CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 5` Capillary, Gold Contacts show more
            • Adjustable Set Point Range:
              • Increasing: +35°F to +140°F, +2°C to +60°C
              • Decreasing: +21°F to +135°F, -6°C to +57°C


            • Deadband: Approximately
              • At Bottom of Range: 14°F, 4°C
              • At Top of Range: 5°F, 3°C

            • Probe Temperature (Maximum): +300°F, +149°C
            • Wetted Materials:
              • Temperature Probe: 300 Stainless Steel & Graphite
              • Capillary Tube: Lubricated Glass Fiber

            • Relay: SPDT
            • Contacts: Gold
            • UL, CE Mark, NACE, General Purpose
            5 - 7 weeks
            Non-Cancellable / Non-Refundable
            Does not ship to OH, United States
            CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 10` Capillary, Gold Contacts
            5 - 7 weeks
            Does not ship to OH, United States
            CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 5` Capillary show more
            • Adjustable Set Point Range:
              • Increasing: +175°F to +310°F, +80°C to +154°C
              • Decreasing: +159°F to +305°F, +71°C to +152°C
              • Deadband: Approximately
                • At Bottom of Range: 16°F, 9°C
                • At Top of Range: 5°F, 2°C
              • Probe Temperature (Maximum): +500°F, +260°C
              • Wetted Materials:
                • Temperature Probe: 300 Stainless Steel & Graphite
                • Capillary Tube: Lubricated Glass Fiber
              • Relay: SPDT
              • UL, CE Mark, NACE, General Purpose
              5 - 7 weeks
              Does not ship to OH, United States
              CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 10` Capillary show more
              • Adjustable Set Point Range:
                • Increasing: +175°F to +310°F, +80°C to +154°C
                • Decreasing: +159°F to +305°F, +71°C to +152°C
                • Deadband: Approximately
                  • At Bottom of Range: 16°F, 9°C
                  • At Top of Range: 5°F, 2°C
                • Probe Temperature (Maximum): +500°F, +260°C
                • Wetted Materials:
                  • Temperature Probe: 300 Stainless Steel & Graphite
                  • Capillary Tube: 10' Capillary, Lubricated Glass Fiber
                • Relay: SPDT
                • UL, CE Mark, NACE, General Purpose
                5 - 7 weeks
                Does not ship to OH, United States
                CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 15` Capillary show more
                • Adjustable Set Point Range:
                  • Increasing: +175°F to +310°F, +80°C to +154°C
                  • Decreasing: +159°F to +305°F, +71°C to +152°C
                  • Deadband: Approximately
                    • At Bottom of Range: 16°F, 9°C
                    • At Top of Range: 5°F, 2°C
                  • Probe Temperature (Maximum): +500°F, +260°C
                  • Wetted Materials:
                    • Temperature Probe: 300 Stainless Steel & Graphite
                    • Capillary Tube: 15' Capillary, Lubricated Glass Fiber
                  • Relay: SPDT
                  • UL, CE Mark, NACE, General Purpose
                  5 - 7 weeks
                  Does not ship to OH, United States
                  CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 5` Capillary, Gold Contacts show more
                  • Adjustable Set Point Range:
                    • Increasing: +175°F to +310°F, +80°C to +154°C
                    • Decreasing: +159°F to +305°F, +71°C to +152°C


                    • Deadband: Approximately
                      • At Bottom of Range: 16°F, 9°C
                      • At Top of Range: 5°F, 2°C

                    • Probe Temperature (Maximum): +500°F, +260°C
                    • Wetted Materials:
                      • Temperature Probe: 300 Stainless Steel & Graphite
                      • Capillary Tube: Lubricated Glass Fiber

                    • Relay: SPDT
                    • Contacts: Gold
                    • UL, CE Mark, NACE, General Purpose
                    5 - 7 weeks
                    Non-Cancellable / Non-Refundable
                    Does not ship to OH, United States
                    CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 10` Capillary, Gold Contacts
                    5 - 7 weeks
                    Does not ship to OH, United States
                    CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 5` Capillary, Gold Contacts show more
                    • Adjustable Set Point Range:
                      • Increasing: +275°F to +420°F, +135°C to +216°C
                      • Decreasing: +256°F to +414°F, +123°C to +212°C


                      • Deadband: Approximately
                        • At Bottom of Range: 19°F, 12°C
                        • At Top of Range: 6°F, 4°C

                      • Probe Temperature (Maximum): +500°F, +260°C
                      • Wetted Materials:
                        • Temperature Probe: 300 Stainless Steel & Graphite
                        • Capillary Tube: Lubricated Glass Fiber

                      • Relay: SPDT
                      • Contacts: Gold
                      • UL, CE Mark, NACE, General Purpose
                      5 - 7 weeks
                      Does not ship to OH, United States
                      CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 5` Capillary, DPDT show more
                      • Adjustable Set Point Range:
                        • Increasing: +175°F to +310°F, +80°C to +154°C
                        • Decreasing: +159°F to +305°F, +71°C to +152°C


                        • Deadband: Approximately
                          • At Bottom of Range: 16°F, 9°C
                          • At Top of Range: 5°F, 2°C

                        • Probe Temperature (Maximum): +500°F, +260°C
                        • Wetted Materials:
                          • Temperature Probe: 300 Stainless Steel & Graphite
                          • Capillary Tube: Lubricated Glass Fiber

                        • Relay: DPDT
                        • UL, CE Mark, NACE, General Purpose
                        5 - 7 weeks
                        Does not ship to OH, United States
                        CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 5` Capillary, DPDT show more
                        • Adjustable Set Point Range:

                          • Increasing: +380°F to +525°F, +193°C to +274°C
                          • Decreasing: +355°F to +520°F, +179°C to +271°C


                          • Deadband: Approximately
                            • At Bottom of Range: 25°F, 4°C
                            • At Top of Range: 5°F, 3°C

                          • Probe Temperature (Maximum): +500°F, +260°C
                          • Wetted Materials:
                            • Temperature Probe: 300 Stainless Steel & Graphite
                            • Capillary Tube: Lubricated Glass Fiber

                          • Relay: DPDT
                          • UL, CE Mark, NACE, General Purpose
                          7 - 9 weeks
                          Does not ship to OH, United States
                          CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 15` Capillary, DPDT show more
                          • Adjustable Set Point Range:
                            • Increasing: +380°F to +525°F, +193°C to +274°C
                            • Decreasing: +355°F to +520°F, +179°C to +271°C
                            • Deadband: Approximately
                              • At Bottom of Range: 25°F, 4°C
                              • At Top of Range: 5°F, 3°C
                            • Probe Temperature (Maximum): +600°F, +316°C
                            • Wetted Materials:
                              • Temperature Probe: 300 Stainless Steel & Graphite
                              • Capillary Tube: 15' Capillary, Lubricated Glass Fiber
                              • Relay: DPDT
                            • UL, CE Mark, NACE, General Purpose
                            5 - 7 weeks
                            Non-Cancellable / Non-Refundable
                            Does not ship to OH, United States
                            CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 5` Capillary, DPDT show more
                            GENERAL DESCRIPTION STD 604TUM2, FACTORY SET, SPECIAL PROBE (1.875) INCR: 130 DEG F DECR: BY 120 DEG F PROOF: 300 DEG F ELEC RATING: STD
                            5 - 7 weeks
                            Does not ship to OH, United States
                            CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 25` Capillary, DPDT show more
                            • Adjustable Set Point Range:

                              • Increasing: +175°F to +310°F, +80°C to +154°C
                              • Decreasing: +159°F to +305°F, +71°C to +152°C


                              • Deadband: Approximately
                                • At Bottom of Range: 16°F, 9°C
                                • At Top of Range: 5°F, 2°C

                              • Probe Temperature (Maximum): +500°F, +260°C
                              • Wetted Materials:
                                • Temperature Probe: 300 Stainless Steel & Graphite
                                • 25' Capillary Tube: Lubricated Glass Fiber

                              • Relay: DPDT
                              • UL, CE Mark, NACE, General Purpose
                              5 - 7 weeks
                              Does not ship to OH, United States

                              Specifications

                              Adjustment Type

                              • Field Adjustable

                              Approvals & Certifications

                              • CE
                              • CRN
                              • CRN - Alberta
                              • CRN - British Columbia
                              • CRN - Manitoba
                              • CRN - N.W. Territories
                              • CRN - Saskatchewan
                              • CSA
                              • cUL
                              • EMC
                              • LVD
                              • PED
                              • RoHS
                              • UL

                              Capillary Length

                              • 10 feet (3 metres)
                              • 15 feet
                              • 25 feet
                              • 5 feet (1.524 metres)

                              Capillary Material

                              • Lubricated Glass Fiber

                              Deadband, Approximate - Bottom of Range

                              • -13° to -4° C (9° to 25° F)
                              • 4° to 13° C (39° to 55° F)

                              Deadband, Approximate - Top of Range

                              • -16° to -14° C (3° to 6° F)
                              • 2° to 8° C (36° to 46° F)

                              Electrical Connectors

                              • Terminal Strip - Internal

                              Electrical Contacts

                              • Gold
                              • Silver

                              Electrical Rating

                              • 1 A at 125 Vac, 50/60 Hz
                              • 15 A at 125/250/480 Vac Resistive, 0.4 A at 125 Vdc, 0.2 A at 250 Vdc
                              • 5 A at 125/250 Vac Resistive, 5 A at 28 Vdc, 0.5 A at 125 Vdc

                              Enclosure, Body Material

                              • Aluminum

                              Environmental Protection

                              • IP65
                              • IP66
                              • NEMA 13
                              • NEMA 4, 13 / IP65, 66

                              Maximum Sensor, Probe Temperature

                              • 121° to 343° C (250° to 650° F)

                              NACE & NIST

                              • NACE MR-0175: 2003

                              NPT Connection

                              • 1/2” NPT Male

                              O-Ring Material

                              • None

                              Operating Temperature

                              • -40° to 86° C (-40° to 187° F)

                              Proof Pressure

                              • bar: 103.4
                              • kPa: 10,342
                              • psig: 1,500

                              Sensor, Probe Material

                              • Stainless Steel & Graphite

                              Set Point - Decreasing

                              • -39° to 329° C
                              • -39° to 329° C (-38° to 624° F)

                              Set Point - Increasing

                              • -34° to 332° C
                              • -34° to 332° C (-29° to 630° F)

                              Standard Features

                              • Internal Case Ground
                              • Weatherproof

                              Switch Type

                              • DPDT
                              • SPDT

                              System Pressure

                              • bar: 86
                              • kPa: 8,618
                              • psig: 1,250

                              Applications

                              • Power Generation
                              • Rail Car
                              • Fluid Management
                              • Manufacturing Process
                              • Utilities, Water Treatment and Waste
                              • Chemical Refining and Processing
                              • Heavy Vehicles
                              • Safety Systems