L10-800-C-E
Kayden CLASSIC® 800 Series Thermal Switch/Transmitter Electronics Module
Price
Request a Quote
Stock
50+ In Stock
Description
- The CLASSIC 800 Series Electronics Module is for use in the following Models: 810, 812, 814, 816, 828, 830 & 832
- Input Power
- 12-24 Vdc
- 115-230 Vac, 50 to 60 Hz
- Outputs
- Dual SPDT Relay Contacts Rated @ 5 Amps Resistive 230 Vac or 24 Vdc Maximum
- Modbus via RS-485
- Advanced Diagnostics
- Any open or shorted connection will result in a FAULT indication that also deactivates all relays and disables the heater circuitry
- An internal watchdog circuit ensures that the microprocessor code is performing as expected, and a secondary external watchdog circuit ensures that the microprocessor itself is functioning. In the event of a malfunction both circuits force the contacts open, illuminate the Fault LED and force the heater off. This prevents the possibility of a “runaway” heater or a high thermal offset.
- Intelligent User Controls
- The Kayden CLASSIC 800 series Display Panel features bright LED indicators for easy viewing even in direct sunlight.
- An adjustable power-on Start-up Bypass Timer is accessible from the Display Panel for low flow alarm pump protection applications. This makes it possible to disable a pump on low flow and have it automatically restart after a predetermined time in the event of a power interruption.
- Four adjustable delay timers allow the introduction of repeatable time delay into the (set point) relay trip function. For example, in a pump protection application this function will shut down the pump after the switch sensor has gone “dry” for the pre-set time (delay) limit.
- The Kayden RCM Software includes the option of locking the CLASSIC 800 Series Display Panel to eliminate field adjustments or tampering.
- Modbus allows multiple Kayden units to be connected to the same communications bus (via RS485) and monitored simultaneously.
Standard Features
- Microprocessor Based Electronics
- Intelligent User Interface
- Continuous Self-Test Diagnostics of Electronics & Sensor
- Temperature Compensation
- Variable Heater Power
- Dual Independent Relays
- Relays are Factory Set to Monitor Flow
- Adjustable Power-on Start-up Bypass Timer
- Adjustable Set Point Deadbands
- 4 Adjustable Independent Switch Point Timers
- Display Panel Lock-Out (controlled via the Kayden RCM Software)
- No Mechanical Jumpers or Trim-pots
- Process Temperature via Modbus and/or One or Both Alarm Relays
Description
- The CLASSIC 800 Series Electronics Module is for use in the following Models: 810, 812, 814, 816, 828, 830 & 832
- Input Power
- 12-24 Vdc
- 115-230 Vac, 50 to 60 Hz
- Outputs
- Dual SPDT Relay Contacts Rated @ 5 Amps Resistive 230 Vac or 24 Vdc Maximum
- Modbus via RS-485
- Advanced Diagnostics
- Any open or shorted connection will result in a FAULT indication that also deactivates all relays and disables the heater circuitry
- An internal watchdog circuit ensures that the microprocessor code is performing as expected, and a secondary external watchdog circuit ensures that the microprocessor itself is functioning. In the event of a malfunction both circuits force the contacts open, illuminate the Fault LED and force the heater off. This prevents the possibility of a “runaway” heater or a high thermal offset.
- Intelligent User Controls
- The Kayden CLASSIC 800 series Display Panel features bright LED indicators for easy viewing even in direct sunlight.
- An adjustable power-on Start-up Bypass Timer is accessible from the Display Panel for low flow alarm pump protection applications. This makes it possible to disable a pump on low flow and have it automatically restart after a predetermined time in the event of a power interruption.
- Four adjustable delay timers allow the introduction of repeatable time delay into the (set point) relay trip function. For example, in a pump protection application this function will shut down the pump after the switch sensor has gone “dry” for the pre-set time (delay) limit.
- The Kayden RCM Software includes the option of locking the CLASSIC 800 Series Display Panel to eliminate field adjustments or tampering.
- Modbus allows multiple Kayden units to be connected to the same communications bus (via RS485) and monitored simultaneously.
Standard Features
- Microprocessor Based Electronics
- Intelligent User Interface
- Continuous Self-Test Diagnostics of Electronics & Sensor
- Temperature Compensation
- Variable Heater Power
- Dual Independent Relays
- Relays are Factory Set to Monitor Flow
- Adjustable Power-on Start-up Bypass Timer
- Adjustable Set Point Deadbands
- 4 Adjustable Independent Switch Point Timers
- Display Panel Lock-Out (controlled via the Kayden RCM Software)
- No Mechanical Jumpers or Trim-pots
- Process Temperature via Modbus and/or One or Both Alarm Relays
Product Series Specifications
Specifications
Brand
Communication
- RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software
Configuration
- Modbus RS-485
Electronics - Standard Features
- *Configurable only from the Kayden RCM Software
- 100 % Digital Design. Electronics are Environmentally Sealed
- 4-Adjustable Independent Switch Point Timers
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out*
- Easy Setup: No Mechanical Jumpers or Trim Pots
- Incrementally Adjustable Heater Power (5 % Steps) with Automatic Over-Range Protection
- Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
- Start-Up Bypass Timer
- Temperature Compensation
- Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode
Input Power
- 12-24 Vdc, 120-240 Vac, 50/60 Hz
Operating Temperature - Electronics
- -55° to 65° C (-67° to 149° F)
Output
- 4-20 mA
Product Series Documentation
Documentation
Product Manuals
Application Notes
- Application Note - Kayden 4-20mA Analog Output pdf 766 KB
- Application Note - Kayden Acid Level Detection pdf 1.4 MB
- Application Note - Kayden Fail Safe pdf 894 KB
- Application Note - Kayden High Level Detection Holding Tank pdf 996 KB
- Application Note - Kayden Monitoring Digester Flow pdf 831 KB
- Application Note - Kayden Oil Water Separation pdf 1.2 MB
- Application Note - Kayden Pulp and Paper Digester Tank pdf 1.1 MB
- Application Note - Kayden Pulp and Paper Skimmer Tank pdf 829 KB
- Application Note - Kayden Pump Monitoring and Protection pdf 1.0 MB
- Application Note - Kayden Pump Monitoring and Protection Remote pdf 1.2 MB
Catalogs
Frequently Bought With
Similar SKUs
810-RAE-I0080-C1G0A-3E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
In Stock
1 - 2 weeks
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 8"U, SST, Lens, CRN
810-RAC-0012-C1B0A-1E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
4 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U, SST, Blind, CSA
P02-RAC-I0100
Kayden CLASSIC 810 Spare Sensor, 1/2" thru 2" MNPT, P02 Series
Kayden Instruments
Request a Quote
2 In Stock
KAYDEN CLASSIC 800 Series Thermal Flow, Level, Interface Sensor, 1/2" NPT, 10"U, SST, CRN
810-RAC-0012-C1B1G-3E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
2 - 5 days
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U, SST, Remote, Lens,CRN
A05-RCM KIT
Serial Communication Adaptor RS-232 to RS-485, A15-321
Kayden Instruments
Request a Quote
25+ In Stock
KAYDEN Remote Kit w/ RCM Software, 2X Communication Cable, RS 485 Connector
Kayden RCM Software Rev 7.2.0
Kayden RCM Software Rev 7.2.0
Kayden Instruments
Request a Quote
In Stock
Kayden RCMS Software Rev 7.2.0
800-4-45-2400-3-ST8
800/810 Series Pressure Transmitter & Switch
Noshok
$708.37USD
$303.79USD
4 In Stock
NOSHOK 800 Series Electronic Indicating Pressure Transmitters, 4-20mA Output, 0-2400 PSIG Threaded
800-2-2-1450-2
800/810 Series Pressure Transmitter & Switch
Noshok
$627.30USD
$269.47USD
1 In Stock
NOSHOK 800 Series Electronic Indicating Transmitter/Switch, 304 SS Housing, 1 N.O. OR N.C. 1/4" MNPT, 0-1450 psig, M12x1