Kayden CLASSIC® 800 Series Thermal Switch/Transmitter Electronics Module

Price
$882.17 USD
Stock
400+ In Stock
Description
  • The Kayden CLASSIC 800 Series Electronics Module is for use in the following CLASSIC Models
    • 810
    • 812
    • 814
    • 816
    • 828
    • 830
    • 832
  • Input Power
    • 12-24 Vdc
    • 115-230 Vac, 50 to 60 Hz
  • Outputs
    • Dual SPDT Relay Contacts Rated @ 5 Amps Resistive 230 Vac or 24 Vdc Maximum
    • Modbus via RS-485
  • Advanced Diagnostics
    • Any open or shorted connection will result in a fault indication that also deactivates all relays and disables the heater circuitry
    • An internal watchdog circuit ensures that the microprocessor code is performing as expected, and a secondary external watchdog circuit ensures that the microprocessor itself is functioning. In the event of a malfunction, both circuits force the contacts open, illuminate the Fault LED and force the heater off. This prevents the possibility of a “runaway” heater or a high thermal offset.
  • Intelligent User Controls
  • The Kayden CLASSIC 800 Series Display Panel features bright LED indicators for easy viewing even in direct sunlight.
  • An adjustable power-on Start-Up Bypass Timer is accessible from the Display Panel for low-flow alarm pump protection applications. This makes it possible to disable a pump on low flow and have it automatically restart after a predetermined time in the event of a power interruption.
  • Four adjustable delay timers allow the introduction of repeatable time delay into the (set point) relay trip function. For example, in a pump protection application, this function will shut down the pump after the switch sensor has gone “dry” for the pre-set time (delay) limit.
  • The Kayden RCM Software includes the option of locking the CLASSIC 800 Series Display Panel to eliminate field adjustments or tampering.
  • Modbus allows multiple Kayden units to be connected to the same communications bus (via RS-485) and monitored simultaneously.
Standard Features
  • 4-Adjustable Independent Switch Point Timers
  • Adjustable Power-On Start-Up Bypass Timer
  • Adjustable Set Point Deadbands
  • Continuous Self-Test Diagnostics of Electronics & Sensor
  • Display Panel Lock-Out (controlled via the Kayden RCM Software)
  • Dual Independent Relays
  • Intelligent User Interface
  • Microprocessor-Based Electronics
  • No Mechanical Jumpers or Trim-pots
  • Process Temperature via Modbus and/or One or Both Alarm Relays
  • Relays are Factory Set to Monitor Flow
  • Temperature Compensation
  • Variable Heater Power
  • The Kayden CLASSIC 800 Series Electronics Module is for use in the following CLASSIC Models
    • 810
    • 812
    • 814
    • 816
    • 828
    • 830
    • 832
  • Input Power
    • 12-24 Vdc
    • 115-230 Vac, 50 to 60 Hz
  • Outputs
    • Dual SPDT Relay Contacts Rated @ 5 Amps Resistive 230 Vac or 24 Vdc Maximum
    • Modbus via RS-485
  • Advanced Diagnostics
    • Any open or shorted connection will result in a fault indication that also deactivates all relays and disables the heater circuitry
    • An internal watchdog circuit ensures that the microprocessor code is performing as expected, and a secondary external watchdog circuit ensures that the microprocessor itself is functioning. In the event of a malfunction, both circuits force the contacts open, illuminate the Fault LED and force the heater off. This prevents the possibility of a “runaway” heater or a high thermal offset.
  • Intelligent User Controls
  • The Kayden CLASSIC 800 Series Display Panel features bright LED indicators for easy viewing even in direct sunlight.
  • An adjustable power-on Start-Up Bypass Timer is accessible from the Display Panel for low-flow alarm pump protection applications. This makes it possible to disable a pump on low flow and have it automatically restart after a predetermined time in the event of a power interruption.
  • Four adjustable delay timers allow the introduction of repeatable time delay into the (set point) relay trip function. For example, in a pump protection application, this function will shut down the pump after the switch sensor has gone “dry” for the pre-set time (delay) limit.
  • The Kayden RCM Software includes the option of locking the CLASSIC 800 Series Display Panel to eliminate field adjustments or tampering.
  • Modbus allows multiple Kayden units to be connected to the same communications bus (via RS-485) and monitored simultaneously.
Standard Features
  • 4-Adjustable Independent Switch Point Timers
  • Adjustable Power-On Start-Up Bypass Timer
  • Adjustable Set Point Deadbands
  • Continuous Self-Test Diagnostics of Electronics & Sensor
  • Display Panel Lock-Out (controlled via the Kayden RCM Software)
  • Dual Independent Relays
  • Intelligent User Interface
  • Microprocessor-Based Electronics
  • No Mechanical Jumpers or Trim-pots
  • Process Temperature via Modbus and/or One or Both Alarm Relays
  • Relays are Factory Set to Monitor Flow
  • Temperature Compensation
  • Variable Heater Power

Specifications

Input Power

  • Universal Power Input
  • 12-24 Vdc, 120-240 Vac, 50/60 Hz

Output

  • 4-20 mA (Thermal Signal, Scaleable) 120 Vac, Max.

Communication

  • Modbus RTU Communication-Alarms, Flow Status & Diagnostics
  • RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software

Electronics - Standard Features

  • *Configurable only from the Kayden RCM Software
  • 100 % Digital Design. Electronics are Environmentally Sealed
  • 4-Adjustable Independent Switch Point Timers
  • Automated Redundant Self-Test Diagnostics
  • Display Panel Lock-Out*
  • Easy Setup: No Mechanical Jumpers or Trim Pots
  • Incrementally Adjustable Heater Power (5 % Steps) with Automatic Over-Range Protection
  • Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
  • Start-Up Bypass Timer
  • Temperature Compensation
  • Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode

Operating Temperature - Electronics

  • -55° to 65° C (-67° to 149° F)

Storage Temperature

  • Store in a clean & dry environment between -30° & 60° C (-22° & 140° F)

Similar SKUs

M10-1B00
M10-1B00
Kayden CLASSIC® Spare Blind Cover, for CLASSIC® 800 Series Local Electronics Enclosure, M10-1B00
Kayden Instruments
$120.76 USD
50+ In Stock
KAYDEN Blind Cover, CLASSIC Series
M10-1G00
M10-1G00
Kayden CLASSIC® Spare Glass Lens Cover, for CLASSIC® 800 Series Local Electronics Enclosure, M10-1G00
Kayden Instruments
$240.79 USD
100+ In Stock
Kayden Glass Lens Cover, CLASSIC® Series
M50-001G
M50-001G
Kayden CLASSIC Spare Glass Lens Cover, for CLASSIC 800 Series Remote Electronics Enclosure, M50-001G
Kayden Instruments
$240.79 USD
11 In Stock
Kayden Remote Glass Lens Cover, CLASSIC® Series, M50-001G
810-RAC-0012-C1B0A-1E
810-RAC-0012-C1B0A-1E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
$1,438.95 USD
1 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U, SST, Blind, CSA
P02-RAE-0020
P02-RAE-0020
Kayden CLASSIC 810 Spare Sensor, 1/2" thru 2" MNPT, P02 Series
Kayden Instruments
$401.32 USD
25+ In Stock
KAYDEN CLASSIC 800 Series Thermal Flow, Level, Interface Sensor, 1" NPT, 2"U, SST, CRN, Rev 5, 2019
P02-RAE-0030
P02-RAE-0030
Kayden CLASSIC 810 Spare Sensor, 1/2" thru 2" MNPT, P02 Series
Kayden Instruments
$438.92 USD
12 In Stock
KAYDEN CLASSIC 800 Series Thermal Flow, Level, Interface Sensor, 1" NPT, 3"U, SST, CRN, Rev 5 2019
P02-RAE-0090
P02-RAE-0090
Kayden CLASSIC 810 Spare Sensor, 1/2" thru 2" MNPT, P02 Series
Kayden Instruments
$656.57 USD
18 In Stock
KAYDEN CLASSIC 800 Series Thermal Flow, Level, Interface Sensor, 1" NPT, 9"U, SST, CRN, Rev 5 2019
A05-RCM KIT
A05-RCM KIT
Serial Communication Adaptor RS-232 to RS-485, A15-321
Kayden Instruments
Request a Quote
25+ In Stock
KAYDEN Remote Kit w/ RCM Software, Two Communication Cable, RS-485 Connector