Images are representations only.

CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Direct Mount

Price
Request a Quote
Stock
25+ In Stock
Does not ship to VA, United States
Description
  • Adjustable Set Point Range
    • Increasing
      • 80°F to 205°F
      • 27°C to 96°C
    • Decreasing
      • 60°F to 198°F
      • 16°C to 92°C 
  • Deadband Approximate:
    • At Bottom of Range: 20°F, 11°C
    • At Top of Range: 5°F, 4°C
  • Probe Temperature Maximum: 300°F, 149°C
  • Probe Length / Width: 4.5" / 0.38"
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, NACE, CRN
  • Adjustable Set Point Range
    • Increasing
      • 80°F to 205°F
      • 27°C to 96°C
    • Decreasing
      • 60°F to 198°F
      • 16°C to 92°C 
  • Deadband Approximate:
    • At Bottom of Range: 20°F, 11°C
    • At Top of Range: 5°F, 4°C
  • Probe Temperature Maximum: 300°F, 149°C
  • Probe Length / Width: 4.5" / 0.38"
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, NACE, CRN

Specifications

Adjustment Type

  • Field Adjustable

Approvals & Certifications

  • ATEX
  • CE
  • CRN
  • CRN - Alberta
  • CRN - British Columbia
  • CRN - Manitoba
  • CRN - N.W. Territories
  • CRN - Saskatchewan
  • CSA
  • cUL
  • Dual Seal
  • IEC Ex
  • LVD
  • PED
  • RoHS
  • RTN
  • UL

Conduit Connection

  • M20 Explosion-proof

Deadband, Approximate - Bottom of Range

  • 11° C (52° F)
  • -7° C (20° F)

Deadband, Approximate - Top of Range

  • -15° C (5° F)
  • 4° C (39° F)

Electrical - Free Leads

  • 18” (45 cm) Free Leads
  • 18” (45 cm) Teflon Leadwire

Electrical Assembly

  • 316 Stainless Steel
  • Hermetic Seal

Electrical Connectors

  • 1/2” NPT Male

Electrical Contacts

  • Gold
  • Silver

Electrical Enclosure Certification

  • ATEX - SIRA Certified for Potentially Explosive Atmospheres. Models 6****Y, II 2 GD Ex d IIC, 08-ATEX-1046X. (Option Y)
  • c-UL, UL/CSA Explosion-proof: Div. 1, 2 Hermetically Sealed Electrical Assembly P/N 46-1058 (46-1061 for M (DPDT) Model Option), Listed by Both Underwriter's Laboratories, Inc. (File No. E32961) & Canadian Standard Association (CSA) Testing Laboratories
  • IECEx - SIRA Certified, SIR 10,0193X (Option Y)

Electrical Rating

  • 1 A at 125 Vac, 50/60 Hz
  • 11 A at 125/250 Vac

Enclosure, Body Material

  • Aluminum
  • Stainless Steel

Environmental Protection

  • IP54
  • IP66
  • NEMA 13
  • NEMA 4, 7, 9, 13 / IP54, 66
  • NEMA 7
  • NEMA 9

Maximum Sensor, Probe Temperature

  • 93° to 260° C (200° to 500° F)

NACE & NIST

  • NACE MR-0175: 2003

NPT Connection

  • 1/2” NPT Male

O-Ring Material

  • None

Operating Temperature

  • -40° to 86° C (-40° to 187° F)

Proof Pressure

  • bar: 103.4
  • kPa: 10,342
  • psig: 1,500

Sensor, Probe Material

  • 300 Stainless Steel

Set Point - Decreasing

  • -18° to 203° C
  • -18° to 203° C (0° to 397° F)

Set Point - Increasing

  • -7° to 207° C
  • -7° to 207° C (20° to 405° F)

Switch Type

  • DPDT
  • SPDT

System Pressure

  • bar: 86
  • kPa: 8,618
  • psig: 1,250