Images are representations only.

832-RA3A-121A-I0070-AV0C-1B0A-1E

Series: Kayden CLASSIC 832 Thermal Flow Switch & Transmitter Brand: Kayden Instruments

KAYDEN CLASSIC Thermal Flow & Level Switch, Modbus, In-Line, 1" 150# RF SST, U=7", Blind, CSA

Price
Request a Quote
Stock
3 - 5 weeks
Description
  • 832: Raised Face or RTJ Flange
  • R: Sensor Temperature Range
    • -55°C to +200°C (-58°F to +392°F) Continuous Service
  • A3: Sensor Material: 316/316L Stainless Steel c/w Nickel Braze
  • A: Process Connection: Raised Face
  • 121: 1", 150 ANSI
  • A: Flange Material: 316/316L Stainless Steel
  • I0070: Insertion "U" Length: 7"
  • A: Bleed Port: 1/4" Threaded - Standard
  • V: Sensor Orientation: Vertical
  • 0: Pipe Schedule: Schedule 40
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
  • E: Language: English
  • Electronics Temperature Range
    • -55°C to 65°C (-67°F to 149°F)
  • Operating Pressure (Maximum)
    • Per Flange Rating (to a max of 1990 psi), ASME B16.5
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • 832: Raised Face or RTJ Flange
  • R: Sensor Temperature Range
    • -55°C to +200°C (-58°F to +392°F) Continuous Service
  • A3: Sensor Material: 316/316L Stainless Steel c/w Nickel Braze
  • A: Process Connection: Raised Face
  • 121: 1", 150 ANSI
  • A: Flange Material: 316/316L Stainless Steel
  • I0070: Insertion "U" Length: 7"
  • A: Bleed Port: 1/4" Threaded - Standard
  • V: Sensor Orientation: Vertical
  • 0: Pipe Schedule: Schedule 40
  • C: Input Power: 12-24 VDC and 115-230 VAC, 50-60 Hz
  • 1: Local Enclosure: Aluminum Flameproof, 1" FNPT
  • B: Cover for Local Enclosure: Flameproof Blind Cover
  • 0A: Remote Electronics Enclosure & Cover: Not Required
  • 1: Agency Approvals: c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
  • E: Language: English
  • Electronics Temperature Range
    • -55°C to 65°C (-67°F to 149°F)
  • Operating Pressure (Maximum)
    • Per Flange Rating (to a max of 1990 psi), ASME B16.5
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer

Specifications

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150#
  • 2” (DN 50) - 300#
  • 2” (DN 50) - 600#
  • 2” (DN 50) - 900#

Flange Size - 3” (DN 80)

  • 3” (DN 80) - 150#
  • 3” (DN 80) - 300#
  • 3” (DN 80) - 600#
  • 3” (DN 80) - 900#

Flange Size - 4” (DN 100)

  • 4” (DN 100) - 150#
  • 4” (DN 100) - 300#
  • 4” (DN 100) - 600#
  • 4” (DN 100) - 900#

Flange Size - 5” (DN 125)

  • 5” (DN 125) - 150#
  • 5” (DN 125) - 300#
  • 5” (DN 125) - 600#
  • 5” (DN 125) - 900#

Flange Size - 6” (DN 150)

  • 6” (DN 150) - 150#
  • 6” (DN 150) - 300#
  • 6” (DN 150) - 600#
  • 6” (DN 150) - 900#

Flange Size - 8” (DN 200)

  • 8” (DN 200) - 150#
  • 8” (DN 200) - 300#
  • 8” (DN 200) - 600#
  • 8” (DN 200) - 900#

Flange Size - 10” (DN 250)

  • 10” (DN 250) - 150#
  • 10” (DN 250) - 300#
  • 10” (DN 250) - 600#
  • 10” (DN 250) - 900#

Switch Type

  • 2 SPDT Sealed Relay Contacts Rated @ 4 Amps Resistive 230 Vac or 30 Vdc, Max.

Operating Pressure - Sensor

  • Maximum

Approvals & Certifications

  • CSA
  • CSA - Local (Sensor) Enclosure Flameproof: Class I, Div. 1, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Group IIB + H₂) Temperature Code: T3 Enclosure Typical 4, IP55 Single Seal Approved Per ANSI/ISA 12.27.01-2003
  • CSA - Remote Electronics Enclosure - Optional Flameproof: Class I, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Groups IIB + H₂) Temperature Code: T3

Sensor, Probe Style

  • InLine

Enclosure Finish

  • Powder-Coated Polyester TGIC

Sensor Orientation

  • Horizontal
  • Vertical

Bleed Port

  • 1/4” Threaded

Wetted Materials

  • 316, 316L Stainless Steel with Nickel Brazing

Operating Temperature - Electronics

  • -55° to 65° C (-67° to 149° F)

Accuracy

  • Flow Service: ± 1.0 % of Set Point Velocity over Operating Range of ± 28° C (± 50° F)
  • Level Service: ± 0.64 cm (0.25”)

Flange Type

  • Raised Face (RF)
  • RTJ - Ring Typical Joint

Electronics - Standard Features

  • *Configurable only from the Kayden RCM Software
  • 100 % Digital Design. Electronics are Environmentally Sealed
  • 4-Adjustable Independent Switch Point Timers
  • Automated Redundant Self-Test Diagnostics
  • Display Panel Lock-Out*
  • Easy Setup: No Mechanical Jumpers or Trim Pots
  • Incrementally Adjustable Heater Power (5 % Steps) with Automatic Over-Range Protection
  • Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
  • Start-Up Bypass Timer
  • Temperature Compensation
  • Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode

Input Power

  • 12-24 Vdc, 115-230 Vac, 50/60 Hz / Universal Power Input
  • Power Consumption: Max.

Enclosure, Body Material

  • Copper-Free Aluminum (Does Not Exceed 0.4 % Copper)

Environmental Protection

  • IP55
  • IP67
  • NEMA 4X
  • TYPE 4

Cover - for Local Enclosure

  • Blind Cover - Flameproof
  • Glass Lens Cover - Flameproof

Pipe Schedule

  • Schedule 40
  • Schedule 80

Flange Material

  • 316, 316L Stainless Steel

Storage Temperature

  • Product Should be Stored in a Clean & Dry Environment between -30° & 60° C (-22° & 140° F)

Response Time

  • Approximately 0.5 to 30 seconds

Enclosure, Body Details

  • 1” NPT Female Conduit Connection
  • Buna-N O-Ring on Cover

Output

  • 4-20 mA (Thermal Signal, Scaleable)

Applications

  • Flow

Communication

  • Modbus RTU Communication-Alarms, Flow Status & Diagnostics
  • RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software

Sensor Assembly Body Lengths

  • Custom Body Lengths: 7” to 72” (18 cm to 182 cm) in 1/2” (1 cm) Increments

Principle of Operation

  • Thermal, Calorimetric

Remote Electronics Enclosure & Cover

  • Glass Lens Cover - Flameproof

Switch Point Range

  • Gases: 0.6 to 20,000 cc/second, Standard Condition: 21° C (70° F) at 14.7 psi (1 Atm)
  • Hydrocarbon-based Liquids: 0.033 to 110 cc/second
  • Water-based Liquids: 0.015 to 50 cc/second

Operating Temperature - Sensor

  • -45° to 200° C (-50° to 392° F)

Remote Control & Monitoring Software

  • Adjust Relay Modes
  • Adjust Set Points 1 & 2
  • Load or Save User Settings
  • Lock or Unlock the Display Panel to Protect the Settings
  • Many Other Adjustable Features
  • Modify Heater Settings to Optimize Response Time
  • Monitor Operating Status
  • Operated Via a Personal Computer Locally or from a Remote Control Center
  • Visualize the Actions of the Process Via the Graphical Display

Documentation

Similar SKUs

810-RAE-0012-C1B0A-1E
810-RAE-0012-C1B0A-1E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
1 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 1.2"U, SST, Blind, CSA
810-RAE-0020-C1B0A-1E
810-RAE-0020-C1B0A-1E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
In Stock 2 - 5 days
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 2"U, SST, Blind, CSA
810-RAE-0030-C1G0A-1E
810-RAE-0030-C1G0A-1E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
In Stock 2 - 5 days
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 3"U, SST, Lens, CSA
810-RAE-0040-C1B0A-1E
810-RAE-0040-C1B0A-1E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
In Stock 2 - 5 days
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 4"U, SST, Blind, CSA
810-RAE-0090-C1B0A-1E
810-RAE-0090-C1B0A-1E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
2 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 9"U, SST, Blind, CSA
810-RAC-0012-C1B0A-1E
810-RAC-0012-C1B0A-1E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
4 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U, SST, Blind, CSA
810-RAC-0020-C1B0A-1E
810-RAC-0020-C1B0A-1E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
In Stock 2 - 5 days
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 2"U, SST, Blind, CSA
810-RAD-0020-C1B0A-1E
810-RAD-0020-C1B0A-1E
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Request a Quote
In Stock 2 - 5 days
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 2"U, SST, Blind, CSA