Images are representations only.

CCS DUAL-SNAP Pressure Switch, Haz. Area, 1/2" NPT SST Port & Diaphragm, Viton, Teflon Leads

Price
Request a Quote
Stock
Lead Time: 5 - 7 weeks
Description
  • Adjustable Set Point Range:

    • Increasing: 50 to 375 psig, 344.8 to 2585.5 kPa, 3.5 to 25.9 bar
    • Decreasing: 16 to 347 psig, 110.4 to 2392.4 kPa, 1.1 to 23.9 ba




    • Deadband: Approximately 28 psi, 193.05 kPa, 1.9 bar
    • System Pressure (Maximum): 3000 psig, 20684.27 kPa, 207 bar
    • Proof Pressure: 5000 psig, 34473.78 kPa, 345 bar
    • Wetted Materials:
      • Pressure Port: 1/2" FNPT 316 Stainless Steel
      • Diaphragm: 316 Stainless Steel
      • O-Ring: Viton

    • Relay: SPDT
    • Wire: Teflon
    • UL, CSA
      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
      • Dual Seal - ANSI/ISA - 12.27.01-2003

    • CRN, CE Mark, NACE
    • Adjustable Set Point Range:

      • Increasing: 50 to 375 psig, 344.8 to 2585.5 kPa, 3.5 to 25.9 bar
      • Decreasing: 16 to 347 psig, 110.4 to 2392.4 kPa, 1.1 to 23.9 ba




      • Deadband: Approximately 28 psi, 193.05 kPa, 1.9 bar
      • System Pressure (Maximum): 3000 psig, 20684.27 kPa, 207 bar
      • Proof Pressure: 5000 psig, 34473.78 kPa, 345 bar
      • Wetted Materials:
        • Pressure Port: 1/2" FNPT 316 Stainless Steel
        • Diaphragm: 316 Stainless Steel
        • O-Ring: Viton

      • Relay: SPDT
      • Wire: Teflon
      • UL, CSA
        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
        • Dual Seal - ANSI/ISA - 12.27.01-2003

      • CRN, CE Mark, NACE

      Specifications

      Set Point Range - Decreasing

      • bar: 0.03 to 146.5
      • kPa: 2.8 to 14,651
      • psig: 0.4 to 2,125

      Service

      • Sour - Oil & Gas

      Proof Pressure

      • bar: 51.7 to 345
      • kPa: 5,171 to 34,473
      • psig: 750 to 5,000

      System Pressure

      • bar: 34.5 to 207
      • kPa: 3,447 to 20,684
      • psig: 500 to 3,000

      Operating Temperature

      • -40° to 86° C (-40° to 187° F)

      Electrical Certification

      • ATEX - Baseefa Certified for Potentially Explosive Atmospheres. Models 646**Y, II 2 GD Ex d IIC, Ex Tb IIIC, Baseefa 05-ATEX-0011X. (Option Y)
      • cUL, UL/CSA, Hazardous Areas, Div. 1, 2

      Electrical Assembly

      • Hermetic Seal

      Set Point Range - Increasing

      • bar: 0.07 to 158.6
      • kPa: 8.3 to 15,858
      • psig: 1.2 to 2,300

      Electrical Rating

      • 1 A at 125 Vac, 50/60 Hz
      • 11 A at 125/250 Vac Resisitve, 5 A at 28 Vdc, 0.5 A at 125 Vdc
      • 15 A at 125/250/480 Vac Resistive, 0.5 A at 125 Vdc, 0.2 A at 250 Vdc

      Electrical Connectors

      • 1/2" NPT Male

      Deadband, Approximate

      • bar: 0.06 to 12.1
      • kPa: 5.6 to 1,206.5
      • psig: 0.8 to 175

      Area Classification

      • Hazardous Area