Images are representations only.
Description
Universal load cells combining accuracy, sturdiness and easiness to install.
Features- Wide range of capacities: 10 kN (1 t) up to 30 MN (3000 t)
- Easy to install, compact design
- Protection IP 66
- Material: stainless steel (5100), nickel plated steel (5105)
- Available options:
- High service temperature (180° C)
- ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
- 0-10 V or 4 to 20 mA output signal
- Also available as standard reference load cells following ISO 376 (EN10002/3) (Class "0.5" and "00")
Configure
Specifications
Specifications
Brand
Accuracy
- 1,000 D
- 2,000 D
- 3,000 D
Applications
- Force Measuring on Test Bench
- Industrial Force Measurement
- Weighing
Approvals & Certifications
- ATEX Intrinsic Safety Ex II 1 GD Ex Ia IIC T6 or T4 Ga Ex Ia IIIC T80° C Da
- CE
- CSA
- IECEx
Capacity
- 1 to 3000 T
Electrical Connectors
- DIN 45322
Enclosure, Body Material
- Nickel-Plated Steel
- Stainless Steel
Environmental Protection
- IP66
Excitation Voltage
- 10 Vdc
- 3-12 Vdc - Nominal Voltage
Insulation Resistance
- > 5,000 MegaOhms
Linearity
- Error: <± 0.025% (0.03 Model) to <± 0.25% of Full Scale (0.25 Model)
Repeatability
- Error: <± 0.1% (0.25 Model) to <± 0.015% of Full Scale (0.03 Model)
Resistance
- Input/Output: 352 ± 2 ohms
Sensitivity
- Tolerance: <± 0.2% (0.03 Model) to <± 0.3% (0.25, 0.1, & 0.05 Model)
Service Temperature
- -30 to 70° C (-22° to 158° F)
Storage Temperature
- -50 to 85° C (-58° to 185° F)
Temperature Coefficient
- <± 0.015% to <± 0.05% of Full Scale/10° C (18° F)
- <± 0.023% to <± 0.035% of Full Scale/10° C (18° F)
Zero Balance
- ± 0.02 mV/V