Images are representations only.

6900TUE Series Temperature Switch

Brand: Custom Control Sensors
The hazardous locations CCS Dual-Snap 6900TUE Series is the most popular, all-around temperature pressure switch with a stainless steel capillary tube and armored jacket probe port fitting.
 
The series is UL/CSA explosion proof, Class I, Groups A, B, C and D, and Class II Groups E, F and G certified, and ATEX/IECEx II 2 G D Ex d IIC and Ex to IIIC. NEMA 4X and IP66 ratings are optimal for wet conditions.
 
It is designed with high vibration and shock resistance, utilizing Dual Snap® disc spring technology, ensuring high accuracy and repeatability.
 
It comes with high over-temperature capabilities and is still relatively compact in size to conveniently mount on panels. It meets the demand for all applications, commercial, industrial, and otherwise.

Features

  • Adjustable Set Point Range
    • Increasing
      • 20° to 650° F
      • -7° to 343° C
    • Decreasing
      • 0° to 640° F
      • -18° to 338° C
  • Deadband - Approximate
    • At Bottom of Range: 20° to 25° F, 11° to 14° C 
    • At Top of Range: 5° to 10° F, 4° to 5° C 
  • Probe Temperature Maximum: 200° to 700° F, 93° to 371° C
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT or DPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, CRN
The hazardous locations CCS Dual-Snap 6900TUE Series is the most popular, all-around temperature pressure switch with a stainless steel capillary tube and armored jacket probe port fitting.
 
The series is UL/CSA explosion proof, Class I, Groups A, B, C and D, and Class II Groups E, F and G certified, and ATEX/IECEx II 2 G D Ex d IIC and Ex to IIIC. NEMA 4X and IP66 ratings are optimal for wet conditions.
 
It is designed with high vibration and shock resistance, utilizing Dual Snap® disc spring technology, ensuring high accuracy and repeatability.
 
It comes with high over-temperature capabilities and is still relatively compact in size to conveniently mount on panels. It meets the demand for all applications, commercial, industrial, and otherwise.

Features

  • Adjustable Set Point Range
    • Increasing
      • 20° to 650° F
      • -7° to 343° C
    • Decreasing
      • 0° to 640° F
      • -18° to 338° C
  • Deadband - Approximate
    • At Bottom of Range: 20° to 25° F, 11° to 14° C 
    • At Top of Range: 5° to 10° F, 4° to 5° C 
  • Probe Temperature Maximum: 200° to 700° F, 93° to 371° C
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT or DPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, CRN
Models matching criteria: 10
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary view more
  • Adjustable Set Point Range
    • Increasing
      • °F   80° to 205°
      • °C   27° to 96°
    • Decreasing
      • °F   60° to 198°
      • °C   16° to 92°
  • Deadband - Approximate:
    • At Bottom of Range: 20°F, 11°C
    • At Top of Range: 5°F, 4°C 
  • Probe Temperature Maximum: 300°F, 149°C
  • Probe Length / Width: 4.5" / 0.38"
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, NACE
25+ In Stock
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary view more
  • Adjustable Set Point Range
    • Increasing
      • °F    20° to 120°
      • °C   -7° to 49°
    • Decreasing
      • °F    0° to 113°
      • °C   -18° to 45°
  • Deadband - Approximate
    • At Bottom of Range: 20°F, 11°C
    • At Top of Range: 5°F, 4°C
  • Probe
    • Temperature Maximum: 200°F, 93°C
    • Length: 4.5"
    • Diameter: 0.38"
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, NACE, CRN
11 In Stock
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary view more
  • Adjustable Set Point Range
    • Increasing
      • °F   385° to 565°
      • °C   196° to 296°
    • Decreasing
      • °F   360° to 555°
      • °C   182° to 291°
  • Deadband - Approximate:
    • At Bottom of Range: 25°F, 14°C
    • At Top of Range: 10°F, 5°C
  • Probe Temperature Maximum: 650°F, 343°C
  • Probe Length / Width: 4.5" / 0.38"
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, NACE, CRN
5 In Stock
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary view more
  • Adjustable Set Point Range
    • Increasing
      • °F   185° to 315°
      • °C   85° to 157°
    • Decreasing
      • °F   165° to 308°
      • °C   74° to 153°
  • Deadband Approximate:
    • At Bottom of Range: 20°F, 11°C
    • At Top of Range: 5°F, 4°C
  • Probe Temperature Maximum: 400°F, 204°C
  • Probe Length / Width: 4.5" / 0.38"
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, NACE, CRN
Contact Us
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary view more
  • Adjustable Set Point Range
    • Increasing
      • °F   280° to 405°
      • °C   138° to 207°
    • Decreasing
      • °F   260° to 398°
      • °C   127° to 203°
  • Deadband - Approximate:
    • At Bottom of Range: 20°F, 11°C 
    • At Top of Range: 5°F, 4°C
  • Probe Temperature Maximum: 500°F, 260°C
  • Probe Length / Width: 4.5" / 0.38"
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, NACE, CRN
Contact Us
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 10` Capillary view more
  • Adjustable Set Point Range
    • Increasing
      • °F   185° to 315°
      • °C   85° to 157°
    • Decreasing
      • °F   165° to 308°
      • °C   74° to 153°
  • Deadband - Approximate:
    • At Bottom of Range: 20°F, 11°C
    • At Top of Range: 5°F, 4°C
  • Probe Temperature Maximum: 400°F, 204°C
  • Probe Length / Width: 4.5" / 0.38"
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 10' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, NACE, CRN
Contact Us
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 10` Capillary view more
  • Adjustable Set Point Range
    • Increasing
      • °F   80° to 205°
      • °C   27° to 96°
    • Decreasing
      • °F   60° to 198°
      • °C   16° to 92°
  • Deadband Approximate:
    • At Bottom of Range: 20°F, 11°C
    • At Top of Range: 5°F, 4°C
  • Probe Temperature Maximum: 300°F, 149°C
  • Probe Length / Width: 4.5" / 0.38"
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 10' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, NACE, CRN
Contact for Inventory
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 10` Capillary, SST Body view more
  • Adjustable Set Point Range:

    • Increasing: +280°F to +405°F, +138°C to +207°C
    • Decreasing: +260°F to +398°F, +127°C to +203°C

  • Deadband: Approximately
    • At Bottom of Range: 20°F, 11°C
    • At Top of Range: 5°F, 4°C

  • Probe Temperature (Maximum): +500°F, +260°C
  • Probe Length / Width: 4.5" / 0.38"
  • Wetted Materials:
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 10' Stainless Steel Graphite & Lubricated Glass

  • Body: Stainless Steel
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

  • CE Mark, NACE, CRN
28 - 35 weeks
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 25` Capillary, DPDT view more
  • Adjustable Set Point Range:

    • Increasing: +185°F to +315°F, +85°C to +157°C
    • Decreasing: +165°F to +308°F, +74°C to +153°C


    • Deadband: Approximately
      • At Bottom of Range: 20°F, 11°C
      • At Top of Range: 5°F, 4°C

    • Probe Temperature (Maximum): +400°F, +204°C
    • Probe Length / Width: 4.5" / 0.38"
    • Wetted Materials:
      • Temperature Probe: 300 Stainless Steel
      • Capillary Tube: 25' Stainless Steel Graphite & Lubricated Glass

    • Relay: DPDT
    • UL, CSA
      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

    • CE Mark, NACE
    28 - 35 weeks
    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 10` Capillary view more
    • Adjustable Set Point Range
      • Increasing
        • °F   385° to 565°
        • °C   196° to 296°
      • Decreasing
        • °F   360° to 555°
        • °C   182° to 291°
    • Deadband - Approximate:
      • At Bottom of Range: 25°F, 14°C
      • At Top of Range: 10°F, 5°C
    • Probe Temperature Maximum: 650°F, 343°C
    • Probe Length / Width: 4.5" / 0.38"
    • Wetted Materials
      • Temperature Probe: 300 Stainless Steel
      • Capillary Tube: 10' Stainless Steel Graphite & Lubricated Glass
    • Relay: SPDT
    • UL, CSA
      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
    • CE Mark, NACE
    Contact Us

    Specifications

    Area Classification

    • Hazardous Area

    Approvals

    • ATEX
    • CE
    • CCC
    • CSA
    • cUL
    • Dual Seal
    • GOST
    • IECEx
    • UL

    Field Adjustable or Pre-Set Set Point

    • Field Adjustable

    Capillary Length

    • 5 ft
    • 10 ft
    • 15 ft
    • 25 ft

    Process Connection Type & Size

    • 1/2"-14 NPT Male

    Process Connection Material

    • 300 Stainless Steel

    NACE

    • NACE MR 0175 / ISO 15156

    O-Ring

    • No O-Ring

    Enclosure Rating

    • IP 66
    • NEMA 4
    • NEMA 7
    • NEMA 9
    • NEMA 13

    Electrical Connection Size

    • 1/2"-14 NPT Male

    Electrical Termination Type

    • Wire Leads 18" : 45 cm
    • Wire Leads 18" : 45 cm Teflon for Low Temp
    • Wire Leads 2 m : 200 cm

    Electrical Contacts Form

    • SPDT
    • DPDT

    Electrical Contacts Material

    • Silver
    • Gold

    Voltage Electrical Rating

    • VAC 0 - 250
    • VDC 0 - 125

    Ampere Rating

    • 0.5 to 11 A

    SIL Level

    • SIL 2
    • SIL 3

    RoHS Compliance

    • Yes

    Housing Material

    • Aluminum
    • Stainless Steel

    Gender

    • Male

    Electrical Rating

    • 1 A at 125 Vac, 50/60 Hz
    • 11 A at 125/250 Vac Resistive, 5 A at 30 Vdc Resistive, 0.5 A at 125 Vdc

    Conduit Connection

    • M20 Explosion-proof

    System Pressure

    • bar: 86
    • kPa: 8,618
    • psig: 1,250

    Set Point Range - Decreasing

    • -18° to 338° C
    • -18° to 338° C (0° to 640° F)

    Proof Pressure

    • bar: 103.4
    • kPa: 10,342
    • psig: 1,500

    Electrical Enclosure Certification

    • ATEX - SIRA Certified for Potentially Explosive Atmospheres. Models 6****Y, II 2 GD Ex d IIC, 08-ATEX-1046X. (Option Y)
    • cUL, UL/CSA, Hazardous Areas, Div. 1, 2
    • IECEx - SIRA Certified, SIR 10,0193X (Option Y)

    Electrical Assembly

    • 316 Stainless Steel
    • Hermetic Seal

    Deadband, Approximate - Top of Range

    • -15° to -12° C (5° to 10° F)
    • 4° to 5° C (39° to 41° F)

    Maximum Sensor, Probe Temperature

    • 93° to 371° C (200° to 700° F)

    Electrical Connectors

    • 1/2" NPT Male

    Set Point Range - Increasing

    • -7° to 343° C
    • -7° to 343° C (20° to 650° F)

    Sensor, Probe Material

    • 300 Stainless Steel

    Capillary Material

    • Stainless Steel, Graphite & Lubricated Glass Fiber

    Operating Temperature

    • -40° to 86° C (-40° to 187° F)

    Capillary Length

    • 10 ft (3 m)
    • 15 ft
    • 25 ft
    • 5 ft (1.524 m)

    Deadband, Approximate - Bottom of Range

    • 11° to 14° C (52° to 57° F)
    • -7° to -4° C (20° to 25° F)

    Area Classification

    • Hazardous Area

    Applications

    • Oil & Gas
    • Power Generation
    • Fluid Management
    • Chemical Refining & Processing
    • Utilities, Water Treatment & Waste
    • Safety Systems