Images are representations only.

6900TUE Series Temperature Switch

Brand: Custom Control Sensors
Does not ship to IL, United States
The hazardous locations CCS Dual-Snap 6900TUE Series is the most popular, all-around temperature pressure switch with a stainless steel capillary tube and armored jacket probe port fitting.
 
The series is UL/CSA explosion proof, Class I, Groups A, B, C and D, and Class II Groups E, F and G certified, and ATEX/IECEx II 2 G D Ex d IIC and Ex to IIIC. NEMA 4X and IP66 ratings are optimal for wet conditions.
 
It is designed with high vibration and shock resistance, utilizing Dual Snap® disc spring technology, ensuring high accuracy and repeatability.
 
It comes with high over-temperature capabilities and is still relatively compact in size to conveniently mount on panels. It meets the demand for all applications, commercial, industrial, and otherwise.

Features

  • Adjustable Set Point Range
    • Increasing
      • 20° to 650° F
      • -7° to 343° C
    • Decreasing
      • 0° to 640° F
      • -18° to 338° C
  • Deadband - Approximate
    • At Bottom of Range: 20° to 25° F, 11° to 14° C 
    • At Top of Range: 5° to 10° F, 4° to 5° C 
  • Probe Temperature Maximum: 200° to 700° F, 93° to 371° C
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT or DPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, CRN
The hazardous locations CCS Dual-Snap 6900TUE Series is the most popular, all-around temperature pressure switch with a stainless steel capillary tube and armored jacket probe port fitting.
 
The series is UL/CSA explosion proof, Class I, Groups A, B, C and D, and Class II Groups E, F and G certified, and ATEX/IECEx II 2 G D Ex d IIC and Ex to IIIC. NEMA 4X and IP66 ratings are optimal for wet conditions.
 
It is designed with high vibration and shock resistance, utilizing Dual Snap® disc spring technology, ensuring high accuracy and repeatability.
 
It comes with high over-temperature capabilities and is still relatively compact in size to conveniently mount on panels. It meets the demand for all applications, commercial, industrial, and otherwise.

Features

  • Adjustable Set Point Range
    • Increasing
      • 20° to 650° F
      • -7° to 343° C
    • Decreasing
      • 0° to 640° F
      • -18° to 338° C
  • Deadband - Approximate
    • At Bottom of Range: 20° to 25° F, 11° to 14° C 
    • At Top of Range: 5° to 10° F, 4° to 5° C 
  • Probe Temperature Maximum: 200° to 700° F, 93° to 371° C
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT or DPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, CRN
Models matching criteria: 62
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary view more
  • Adjustable Set Point Range
    • Increasing
      • °F   80° to 205°
      • °C   27° to 96°
    • Decreasing
      • °F   60° to 198°
      • °C   16° to 92°
  • Deadband - Approximate:
    • At Bottom of Range: 20°F, 11°C
    • At Top of Range: 5°F, 4°C 
  • Probe Temperature Maximum: 300°F, 149°C
  • Probe Length / Width: 4.5" / 0.38"
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, NACE
Does not ship to IL, United States
Limited Stock
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary view more
  • Adjustable Set Point Range
    • Increasing
      • °F    20° to 120°
      • °C   -7° to 49°
    • Decreasing
      • °F    0° to 113°
      • °C   -18° to 45°
  • Deadband - Approximate
    • At Bottom of Range: 20°F, 11°C
    • At Top of Range: 5°F, 4°C
  • Probe
    • Temperature Maximum: 200°F, 93°C
    • Length: 4.5"
    • Diameter: 0.38"
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, NACE, CRN
11 In Stock
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary view more
  • Adjustable Set Point Range
    • Increasing
      • °F   385° to 565°
      • °C   196° to 296°
    • Decreasing
      • °F   360° to 555°
      • °C   182° to 291°
  • Deadband - Approximate:
    • At Bottom of Range: 25°F, 14°C
    • At Top of Range: 10°F, 5°C
  • Probe Temperature Maximum: 650°F, 343°C
  • Probe Length / Width: 4.5" / 0.38"
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, NACE, CRN
Does not ship to IL, United States
5 In Stock
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary view more
  • Adjustable Set Point Range
    • Increasing
      • °F   185° to 315°
      • °C   85° to 157°
    • Decreasing
      • °F   165° to 308°
      • °C   74° to 153°
  • Deadband Approximate:
    • At Bottom of Range: 20°F, 11°C
    • At Top of Range: 5°F, 4°C
  • Probe Temperature Maximum: 400°F, 204°C
  • Probe Length / Width: 4.5" / 0.38"
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, NACE, CRN
Does not ship to IL, United States
Contact Us
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary view more
  • Adjustable Set Point Range
    • Increasing
      • °F   280° to 405°
      • °C   138° to 207°
    • Decreasing
      • °F   260° to 398°
      • °C   127° to 203°
  • Deadband - Approximate:
    • At Bottom of Range: 20°F, 11°C 
    • At Top of Range: 5°F, 4°C
  • Probe Temperature Maximum: 500°F, 260°C
  • Probe Length / Width: 4.5" / 0.38"
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel
    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, NACE, CRN
Does not ship to IL, United States
Contact Us
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 15` Capillary view more
  • Adjustable Set Point Range:

    • Increasing: +20°F to +120°F, -7°C to +49°C
    • Decreasing: +0°F to +113°F, -18°C to +45°C


    • Deadband: Approximately
      • At Bottom of Range: 20°F, 11°C
      • At Top of Range: 5°F, 4°C

    • Probe Temperature (Maximum): +200°F, +93°C
    • Probe Length / Width: 4.5" / 0.38"
    • Wetted Materials:
      • Temperature Probe: 300 Stainless Steel
      • Capillary Tube: 15' Stainless Steel Graphite & Lubricated Glass

    • Relay: SPDT
    • UL, CSA
      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

    • CE Mark, NACE
    Does not ship to IL, United States
    18 - 20 weeks
    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 25` Capillary view more
    • Adjustable Set Point Range:

      • Increasing: +80°F to +205°F, +27°C to +96°C
      • Decreasing: +60°F to +198°F, +16°C to +92°C


      • Deadband: Approximately
        • At Bottom of Range: 20°F, 11°C
        • At Top of Range: 5°F, 4°C

      • Probe Temperature (Maximum): +300°F, +149°C
      • Probe Length / Width: 4.5" / 0.38"
      • Wetted Materials:
        • Temperature Probe: 300 Stainless Steel
        • Capillary Tube: 25' Stainless Steel Graphite & Lubricated Glass

      • Relay: SPDT
      • UL, CSA
        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

      • CE Mark, NACE
      Does not ship to IL, United States
      28 - 35 weeks
      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 10` Capillary view more
      • Adjustable Set Point Range
        • Increasing
          • °F   185° to 315°
          • °C   85° to 157°
        • Decreasing
          • °F   165° to 308°
          • °C   74° to 153°
      • Deadband - Approximate:
        • At Bottom of Range: 20°F, 11°C
        • At Top of Range: 5°F, 4°C
      • Probe Temperature Maximum: 400°F, 204°C
      • Probe Length / Width: 4.5" / 0.38"
      • Wetted Materials
        • Temperature Probe: 300 Stainless Steel
        • Capillary Tube: 10' Stainless Steel Graphite & Lubricated Glass
      • Relay: SPDT
      • UL, CSA
        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
      • CE Mark, NACE, CRN
      Does not ship to IL, United States
      Contact Us
      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 15` Capillary view more
      • Adjustable Set Point Range:

        • Increasing: +185°F to +315°F, +85°C to +157°C
        • Decreasing: +165°F to +308°F, +74°C to +153°C


        • Deadband: Approximately
          • At Bottom of Range: 20°F, 11°C
          • At Top of Range: 5°F, 4°C

        • Probe Temperature (Maximum): +400°F, +204°C
        • Probe Length / Width: 4.5" / 0.38"
        • Wetted Materials:
          • Temperature Probe: 300 Stainless Steel
          • Capillary Tube: 15' Stainless Steel Graphite & Lubricated Glass

        • Relay: SPDT
        • UL, CSA
          • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

        • CE Mark, NACE
        Does not ship to IL, United States
        28 - 35 weeks
        CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 25` Capillary view more
        • Adjustable Set Point Range:

          • Increasing: +185°F to +315°F, +85°C to +157°C
          • Decreasing: +165°F to +308°F, +74°C to +153°C


          • Deadband: Approximately
            • At Bottom of Range: 20°F, 11°C
            • At Top of Range: 5°F, 4°C

          • Probe Temperature (Maximum): +400°F, +204°C
          • Probe Length / Width: 4.5" / 0.38"
          • Wetted Materials:
            • Temperature Probe: 300 Stainless Steel
            • Capillary Tube: 25' Stainless Steel Graphite & Lubricated Glass

          • Relay: SPDT
          • UL, CSA
            • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

          • CE Mark, NACE
          Does not ship to IL, United States
          28 - 35 weeks
          CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 10` Capillary view more
          • Adjustable Set Point Range:

            • Increasing: +280°F to +405°F, +138°C to +207°C
            • Decreasing: +260°F to +398°F, +127°C to +203°C


            • Deadband: Approximately
              • At Bottom of Range: 20°F, 11°C
              • At Top of Range: 5°F, 4°C

            • Probe Temperature (Maximum): +500°F, +260°C
            • Probe Length / Width: 4.5" / 0.38"
            • Wetted Materials:
              • Temperature Probe: 300 Stainless Steel
              • Capillary Tube: 10' Stainless Steel Graphite & Lubricated Glass

            • Relay: SPDT
            • UL, CSA
              • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

            • CE Mark, NACE, CRN
            Does not ship to IL, United States
            28 - 35 weeks
            CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 25` Capillary view more
            • Adjustable Set Point Range:

              • Increasing: +280°F to +405°F, +138°C to +207°C
              • Decreasing: +260°F to +398°F, +127°C to +203°C


              • Deadband: Approximately
                • At Bottom of Range: 20°F, 11°C
                • At Top of Range: 5°F, 4°C

              • Probe Temperature (Maximum): +500°F, +260°C
              • Probe Length / Width: 4.5" / 0.38"
              • Wetted Materials:
                • Temperature Probe: 300 Stainless Steel
                • Capillary Tube: 25' Stainless Steel Graphite & Lubricated Glass

              • Relay: SPDT
              • UL, CSA
                • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

              • CE Mark, NACE
              Does not ship to IL, United States
              28 - 35 weeks
              CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary view more
              • Adjustable Set Point Range:

                • Increasing: +465°F to +650°F, +241°C to +343°C
                • Decreasing: +440°F to +640°F, +227°C to +338°C

              • Deadband: Approximately
                • At Bottom of Range: 25°F, 14°C
                • At Top of Range: 10°F, 5°C

              • Probe Temperature (Maximum): +700°F, +371°C
              • Probe Length / Width: 4.5" / 0.38"
              • Wetted Materials
                • Temperature Probe: 300 Stainless Steel
                • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass

              • Relay: SPDT
              • UL, CSA
                • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

              • CE Mark, NACE, CRN
              Does not ship to IL, United States
              24 - 26 weeks
              CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary, DPDT view more
              • Adjustable Set Point Range:

                • Increasing: +20°F to +120°F, -7°C to +49°C
                • Decreasing: +0°F to +113°F, -18°C to +45°C


                • Deadband: Approximately
                  • At Bottom of Range: 20°F, 11°C
                  • At Top of Range: 5°F, 4°C

                • Probe Temperature (Maximum): +200°F, +93°C
                • Probe Length / Width: 4.5" / 0.38"
                • Wetted Materials:
                  • Temperature Probe: 300 Stainless Steel
                  • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass

                • Relay: DPDT
                • UL, CSA
                  • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                • CE Mark, NACE
                Does not ship to IL, United States
                28 - 35 weeks
                CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary, DPDT view more
                • Adjustable Set Point Range:

                  • Increasing: +80°F to +205°F, +27°C to +96°C
                  • Decreasing: +60°F to +198°F, +16°C to +92°C


                  • Deadband: Approximately
                    • At Bottom of Range: 20°F, 11°C
                    • At Top of Range: 5°F, 4°C

                  • Probe Temperature (Maximum): +300°F, +149°C
                  • Probe Length / Width: 4.5" / 0.38"
                  • Wetted Materials:
                    • Temperature Probe: 300 Stainless Steel
                    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass

                  • Relay: DPDT
                  • UL, CSA
                    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                  • CE Mark, NACE, CRN
                  Does not ship to IL, United States
                  28 - 35 weeks
                  CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 10` Capillary, DPDT view more
                  • Adjustable Set Point Range:

                    • Increasing: +80°F to +205°F, +27°C to +96°C
                    • Decreasing: +60°F to +198°F, +16°C to +92°C


                    • Deadband: Approximately
                      • At Bottom of Range: 20°F, 11°C
                      • At Top of Range: 5°F, 4°C

                    • Probe Temperature (Maximum): +300°F, +149°C
                    • Probe Length / Width: 4.5" / 0.38"
                    • Wetted Materials:
                      • Temperature Probe: 300 Stainless Steel
                      • Capillary Tube: 10' Stainless Steel Graphite & Lubricated Glass

                    • Relay: DPDT
                    • UL, CSA
                      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                    • CE Mark, NACE
                    Does not ship to IL, United States
                    28 - 35 weeks
                    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 15` Capillary, DPDT view more
                    • Adjustable Set Point Range:

                      • Increasing: +80°F to +205°F, +27°C to +96°C
                      • Decreasing: +60°F to +198°F, +16°C to +92°C


                      • Deadband: Approximately
                        • At Bottom of Range: 20°F, 11°C
                        • At Top of Range: 5°F, 4°C

                      • Probe Temperature (Maximum): +300°F, +149°C
                      • Probe Length / Width: 4.5" / 0.38"
                      • Wetted Materials:
                        • Temperature Probe: 300 Stainless Steel
                        • Capillary Tube: 15' Stainless Steel Graphite & Lubricated Glass

                      • Relay: DPDT
                      • UL, CSA
                        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                      • CE Mark, NACE
                      Does not ship to IL, United States
                      28 - 35 weeks
                      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 25` Capillary, DPDT view more
                      • Adjustable Set Point Range:

                        • Increasing: +80°F to +205°F, +27°C to +96°C
                        • Decreasing: +60°F to +198°F, +16°C to +92°C


                        • Deadband: Approximately
                          • At Bottom of Range: 20°F, 11°C
                          • At Top of Range: 5°F, 4°C

                        • Probe Temperature (Maximum): +300°F, +149°C
                        • Probe Length / Width: 4.5" / 0.38"
                        • Wetted Materials:
                          • Temperature Probe: 300 Stainless Steel
                          • Capillary Tube: 25' Stainless Steel Graphite & Lubricated Glass

                        • Relay: DPDT
                        • UL, CSA
                          • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                        • CE Mark, NACE
                        Does not ship to IL, United States
                        28 - 35 weeks
                        CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary, DPDT view more
                        • Adjustable Set Point Range:

                          • Increasing: +185°F to +315°F, +85°C to +157°C
                          • Decreasing: +165°F to +308°F, +74°C to +153°C


                          • Deadband: Approximately
                            • At Bottom of Range: 20°F, 11°C
                            • At Top of Range: 5°F, 4°C

                          • Probe Temperature (Maximum): +400°F, +204°C
                          • Probe Length / Width: 4.5" / 0.38"
                          • Wetted Materials:
                            • Temperature Probe: 300 Stainless Steel
                            • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass

                          • Relay: DPDT
                          • UL, CSA
                            • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                          • CE Mark, NACE, CRN
                          Does not ship to IL, United States
                          Contact For Inventory
                          CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 10` Capillary, DPDT view more
                          • Adjustable Set Point Range:

                            • Increasing: +185°F to +315°F, +85°C to +157°C
                            • Decreasing: +165°F to +308°F, +74°C to +153°C


                            • Deadband: Approximately
                              • At Bottom of Range: 20°F, 11°C
                              • At Top of Range: 5°F, 4°C

                            • Probe Temperature (Maximum): +400°F, +204°C
                            • Probe Length / Width: 4.5" / 0.38"
                            • Wetted Materials:
                              • Temperature Probe: 300 Stainless Steel
                              • Capillary Tube: 10' Stainless Steel Graphite & Lubricated Glass

                            • Relay: DPDT
                            • UL, CSA
                              • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                            • CE Mark, NACE, CRN
                            Does not ship to IL, United States
                            28 - 35 weeks
                            CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 10` Capillary view more
                            • Adjustable Set Point Range:

                              • Increasing: +20°F to +120°F, -7°C to +49°C
                              • Decreasing: +0°F to +113°F, -18°C to +45°C


                              • Deadband: Approximately
                                • At Bottom of Range: 20°F, 11°C
                                • At Top of Range: 5°F, 4°C

                              • Probe Temperature (Maximum): +200°F, +93°C
                              • Probe Length / Width: 4.5" / 0.38"
                              • Wetted Materials:
                                • Temperature Probe: 300 Stainless Steel
                                • Capillary Tube: 10' Stainless Steel Graphite & Lubricated Glass

                              • Relay: SPDT
                              • UL, CSA
                                • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                              • CE Mark, NACE
                              Does not ship to IL, United States
                              28 - 35 weeks
                              CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 10' Capillary, Teflon Leads view more
                              • Adjustable Set Point Range:

                                • Increasing: +20°F to +120°F, -7°C to +49°C
                                • Decreasing: +0°F to +113°F, -18°C to +45°C


                                • Deadband: Approximately
                                  • At Bottom of Range: 20°F, 11°C
                                  • At Top of Range: 5°F, 4°C

                                • Probe Temperature (Maximum): +200°F, +93°C
                                • Probe Length / Width: 4.5" / 0.38"
                                • Wetted Materials:
                                  • Temperature Probe: 300 Stainless Steel
                                  • Capillary Tube: 10' Stainless Steel Graphite & Lubricated Glass

                                • Wire: Teflon
                                • Relay: SPDT
                                • UL, CSA
                                  • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                • CE Mark, NACE
                                Does not ship to IL, United States
                                28 - 35 weeks
                                CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 25` Capillary view more
                                • Adjustable Set Point Range:

                                  • Increasing: +20°F to +120°F, -7°C to +49°C
                                  • Decreasing: +0°F to +113°F, -18°C to +45°C


                                  • Deadband: Approximately
                                    • At Bottom of Range: 20°F, 11°C
                                    • At Top of Range: 5°F, 4°C

                                  • Probe Temperature (Maximum): +200°F, +93°C
                                  • Probe Length / Width: 4.5" / 0.38"
                                  • Wetted Materials:
                                    • Temperature Probe: 300 Stainless Steel
                                    • Capillary Tube: 25' Stainless Steel Graphite & Lubricated Glass

                                  • Relay: SPDT
                                  • UL, CSA
                                    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                  • CE Mark, NACE
                                  Does not ship to IL, United States
                                  28 - 35 weeks
                                  CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary, SST Body view more
                                  • Adjustable Set Point Range:

                                    • Increasing: +20°F to +120°F, -7°C to +49°C
                                    • Decreasing: +0°F to +113°F, -18°C to +45°C

                                  • Deadband: Approximately
                                    • At Bottom of Range: 20°F, 11°C
                                    • At Top of Range: 5°F, 4°C

                                  • Probe Temperature (Maximum): +200°F, +93°C
                                  • Probe Length / Width: 4.5" / 0.38"
                                  • Wetted Materials:
                                    • Temperature Probe: 300 Stainless Steel
                                    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass

                                  • Wire: Teflon, Explosion Proof Electrical
                                  • Relay: SPDT
                                  • UL, CSA
                                    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                  • CE Mark, NACE, CRN
                                  Does not ship to IL, United States
                                  28 - 35 weeks
                                  CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 10' Capillary, Teflon Leads view more
                                  • Adjustable Set Point Range:

                                    • Increasing: +80°F to +205°F, +27°C to +96°C
                                    • Decreasing: +60°F to +198°F, +16°C to +92°C


                                    • Deadband: Approximately
                                      • At Bottom of Range: 20°F, 11°C
                                      • At Top of Range: 5°F, 4°C

                                    • Probe Temperature (Maximum): +300°F, +149°C
                                    • Probe Length / Width: 4.5" / 0.38"
                                    • Wetted Materials:
                                      • Temperature Probe: 300 Stainless Steel
                                      • Capillary Tube: 10' Stainless Steel Graphite & Lubricated Glass

                                    • Wire: Teflon
                                    • Relay: SPDT
                                    • UL, CSA
                                      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                    • CE Mark, NACE
                                    Does not ship to IL, United States
                                    28 - 35 weeks
                                    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary, Epoxy Coated view more
                                    • Adjustable Set Point Range:

                                      • Increasing: +80°F to +205°F, +27°C to +96°C
                                      • Decreasing: +60°F to +198°F, +16°C to +92°C


                                      • Deadband: Approximately
                                        • At Bottom of Range: 20°F, 11°C
                                        • At Top of Range: 5°F, 4°C

                                      • Probe Temperature (Maximum): +300°F, +149°C
                                      • Probe Length / Width: 4.5" / 0.38"
                                      • Wetted Materials:
                                        • Temperature Probe: 300 Stainless Steel
                                        • Capillary Tube: 10' Stainless Steel Graphite & Lubricated Glass

                                      • Relay: SPDT
                                      • UL, CSA
                                        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                      • CE Mark, NACE
                                      Does not ship to IL, United States
                                      28 - 35 weeks
                                      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary, Gold Contacts view more
                                      • Adjustable Set Point Range:

                                        • Increasing: +80°F to +205°F, +27°C to +96°C
                                        • Decreasing: +60°F to +198°F, +16°C to +92°C

                                      • Deadband: Approximately
                                        • At Bottom of Range: 20°F, 11°C
                                        • At Top of Range: 5°F, 4°C

                                      • Probe Temperature (Maximum): +300°F, +149°C
                                      • Probe Length / Width: 4.5" / 0.38"
                                      • Wetted Materials:
                                        • Temperature Probe: 300 Stainless Steel
                                        • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass

                                      • Contacts: Gold
                                      • Relay: SPDT
                                      • UL, CSA
                                        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                      • CE Mark, NACE, CRN
                                      Does not ship to IL, United States
                                      28 - 35 weeks
                                      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, Gold Contacts, 5` Capillary view more
                                      • Adjustable Set Point Range:

                                        • Increasing: +280°F to +405°F, +138°C to +207°C
                                        • Decreasing: +260°F to +398°F, +127°C to +203°C

                                      • Deadband: Approximately
                                        • At Bottom of Range: 20°F, 11°C
                                        • At Top of Range: 5°F, 4°C

                                      • Probe Temperature (Maximum): +500°F, +260°C
                                      • Probe Length / Width: 4.5" / 0.38"
                                      • Wetted Materials:
                                        • Temperature Probe: 300 Stainless Steel
                                        • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass

                                      • Relay: SPDT
                                      • Contacts: Gold
                                      • UL, CSA
                                        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                      • CE Mark, NACE, CRN
                                      Does not ship to IL, United States
                                      28 - 35 weeks
                                      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 15` Capillary view more
                                      • Adjustable Set Point Range:

                                        • Increasing: +385°F to +565°F, +196°C to +296°C
                                        • Decreasing: +360°F to +555°F, +182°C to +291°C


                                        • Deadband: Approximately
                                          • At Bottom of Range: 25°F, 14°C
                                          • At Top of Range: 10°F, 5°C

                                        • Probe Temperature (Maximum): +650°F, +343°C
                                        • Probe Length / Width: 4.5" / 0.38"
                                        • Wetted Materials:
                                          • Temperature Probe: 300 Stainless Steel
                                          • Capillary Tube: 15' Stainless Steel Graphite & Lubricated Glass

                                        • Relay: SPDT
                                        • UL, CSA
                                          • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                        • CE Mark, NACE
                                        Does not ship to IL, United States
                                        28 - 35 weeks
                                        CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 10` Capillary view more
                                        • Adjustable Set Point Range:

                                          • Increasing: +465°F to +650°F, +241°C to +343°C
                                          • Decreasing: +440°F to +640°F, +227°C to +338°C


                                          • Deadband: Approximately
                                            • At Bottom of Range: 25°F, 14°C
                                            • At Top of Range: 10°F, 5°C

                                          • Probe Temperature (Maximum): +700°F, +371°C
                                          • Probe Length / Width: 4.5" / 0.38"
                                          • Wetted Materials:
                                            • Temperature Probe: 300 Stainless Steel
                                            • Capillary Tube: 10' Stainless Steel Graphite & Lubricated Glass

                                          • Relay: SPDT
                                          • UL, CSA
                                            • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                          • CE Mark, NACE
                                          Does not ship to IL, United States
                                          28 - 35 weeks
                                          CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary, Teflon Leads view more
                                          • Adjustable Set Point Range:

                                            • Increasing: +465°F to +650°F, +241°C to +343°C
                                            • Decreasing: +440°F to +640°F, +227°C to +338°C


                                            • Deadband: Approximately
                                              • At Bottom of Range: 25°F, 14°C
                                              • At Top of Range: 10°F, 5°C

                                            • Probe Temperature (Maximum): +700°F, +371°C
                                            • Probe Length / Width: 4.5" / 0.38"
                                            • Wetted Materials:
                                              • Temperature Probe: 300 Stainless Steel
                                              • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass

                                            • Relay: SPDT
                                            • Free Leadds: 18 inch Teflon
                                            • UL, CSA
                                              • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                            • CE Mark, NACE, CRN
                                            Does not ship to IL, United States
                                            Contact For Inventory
                                            CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 25` Capillary, DPDT view more
                                            • Adjustable Set Point Range:

                                              • Increasing: +20°F to +120°F, -7°C to +49°C
                                              • Decreasing: +0°F to +113°F, -18°C to +45°C


                                              • Deadband: Approximately
                                                • At Bottom of Range: 20°F, 11°C
                                                • At Top of Range: 5°F, 4°C

                                              • Probe Temperature (Maximum): +200°F, +93°C
                                              • Probe Length / Width: 4.5" / 0.38"
                                              • Wetted Materials:
                                                • Temperature Probe: 300 Stainless Steel
                                                • Capillary Tube: 25' Stainless Steel Graphite & Lubricated Glass

                                              • Relay: DPDT
                                              • UL, CSA
                                                • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                              • CE Mark, NACE
                                              Does not ship to IL, United States
                                              28 - 35 weeks
                                              CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 15` Capillary, DPDT view more
                                              • Adjustable Set Point Range:

                                                • Increasing: +185°F to +315°F, +85°C to +157°C
                                                • Decreasing: +165°F to +308°F, +74°C to +153°C


                                                • Deadband: Approximately
                                                  • At Bottom of Range: 20°F, 11°C
                                                  • At Top of Range: 5°F, 4°C

                                                • Probe Temperature (Maximum): +400°F, +204°C
                                                • Probe Length / Width: 4.5" / 0.38"
                                                • Wetted Materials:
                                                  • Temperature Probe: 300 Stainless Steel
                                                  • Capillary Tube: 15' Stainless Steel Graphite & Lubricated Glass

                                                • Relay: DPDT
                                                • UL, CSA
                                                  • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                                • CE Mark, NACE
                                                Does not ship to IL, United States
                                                28 - 35 weeks
                                                CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary, DPDT,ATEX,Gold view more
                                                • Adjustable Set Point Range:

                                                  • Increasing: +20°F to +120°F, -7°C to +49°C
                                                  • Decreasing: +0°F to +113°F, -18°C to +45°C


                                                  • Deadband: Approximately
                                                    • At Bottom of Range: 20°F, 11°C
                                                    • At Top of Range: 5°F, 4°C

                                                  • Probe Temperature (Maximum): +200°F, +93°C
                                                  • Probe Length / Width: 4.5" / 0.38"
                                                  • Wetted Materials:
                                                    • Temperature Probe: 300 Stainless Steel
                                                    • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass

                                                  • Relay: DPDT
                                                  • Contacts: Gold
                                                  • ATEX
                                                    • ATEX Certified For Potentially Explosive Atmospheres Electrical Assembly Series
                                                    • 46-XXXXXXX, Models 6*****, Ex d IIC T6, Directive 94/9/EC Sira #08ATEX 1046X (Option Y)
                                                    • IECEx - SIRA Certified, SIR 10,0193X (Option Y)

                                                  • CE Mark, NACE, GOST, CRN
                                                  Does not ship to IL, United States
                                                  28 - 35 weeks
                                                  CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary, ATEX view more
                                                  • Adjustable Set Point Range:

                                                    • Increasing: +20°F to +120°F, -7°C to +49°C
                                                    • Decreasing: +0°F to +113°F, -18°C to +45°C


                                                    • Deadband: Approximately
                                                      • At Bottom of Range: 20°F, 11°C
                                                      • At Top of Range: 5°F, 4°C

                                                    • Probe Temperature (Maximum): +200°F, +93°C
                                                    • Probe Length / Width: 4.5" / 0.38"
                                                    • Wetted Materials:
                                                      • Temperature Probe: 300 Stainless Steel
                                                      • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass

                                                    • Relay: SPDT
                                                    • ATEX
                                                      • ATEX Certified For Potentially Explosive Atmospheres Electrical Assembly Series
                                                      • 46-XXXXXXX, Models 6*****, Ex d IIC T6, Directive 94/9/EC Sira #08ATEX 1046X (Option Y)
                                                      • IECEx - SIRA Certified, SIR 10,0193X (Option Y)

                                                    • CE Mark, NACE, CRN
                                                    Does not ship to IL, United States
                                                    28 - 35 weeks
                                                    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary, ATEX view more
                                                    • Adjustable Set Point Range:

                                                      • Increasing: +80°F to +205°F, +27°C to +96°C
                                                      • Decreasing: +60°F to +198°F, +16°C to +92°C

                                                    • Deadband: Approximately
                                                      • At Bottom of Range: 20°F, 11°C
                                                      • At Top of Range: 5°F, 4°C

                                                    • Probe Temperature (Maximum): +300°F, +149°C
                                                    • Probe Length / Width: 4.5" / 0.38"
                                                    • Wetted Materials:
                                                      • Temperature Probe: 300 Stainless Steel
                                                      • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass

                                                    • Relay: SPDT
                                                    • UL, CSA, ATEX
                                                      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                                    • CE Mark, NACE, CRN
                                                    Does not ship to IL, United States
                                                    28 - 35 weeks
                                                    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 5` Capillary, ATEX view more
                                                    • Adjustable Set Point Range:

                                                      • Increasing: +280°F to +405°F, +138°C to +207°C
                                                      • Decreasing: +260°F to +398°F, +127°C to +203°C

                                                    • Deadband: Approximately
                                                      • At Bottom of Range: 20°F, 11°C
                                                      • At Top of Range: 5°F, 4°C

                                                    • Probe Temperature (Maximum): +500°F, +260°C
                                                    • Probe Length / Width: 4.5" / 0.38"
                                                    • Wetted Materials:
                                                      • Temperature Probe: 300 Stainless Steel
                                                      • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass

                                                    • Relay: SPDT
                                                    • UL, CSA, ATEX
                                                      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                                    • CE Mark, NACE, CRN
                                                    Does not ship to IL, United States
                                                    28 - 35 weeks
                                                    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300SST Fitting, 5` Capillary, ATEX/GOST view more
                                                    • Adjustable Set Point Range:
                                                    • Increasing: +385°F to +565°F, +196°C to +296°C
                                                    • Decreasing: +360°F to +555°F, +182°C to +291°C
                                                    • Deadband: Approximately
                                                      • At Bottom of Range: 25°F, 14°C
                                                      • At Top of Range: 10°F, 5°C

                                                    • Probe Temperature (Maximum): +650°F, +343°C
                                                    • Probe Length / Width: 4.5" / 0.38"
                                                    • Wetted Materials:
                                                      • Temperature Probe: 300 Stainless Steel
                                                      • Capillary Tube: 5' Stainless Steel Graphite & Lubricated Glass

                                                    • Relay: SPDT
                                                    • ATEX
                                                      • ATEX Certified For Potentially Explosive Atmospheres Electrical Assembly Series
                                                      • 46-XXXXXXX, Models 6*****, Ex d IIC T6, Directive 94/9/EC Sira #08ATEX 1046X (Option Y)
                                                      • IECEx - SIRA Certified, SIR 10,0193X (Option Y)

                                                    • CE Mark, NACE, GOST
                                                    • CRN
                                                    Does not ship to IL, United States
                                                    28 - 35 weeks
                                                    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 25` Capillary, DPDT view more
                                                    • Adjustable Set Point Range:

                                                      • Increasing: +185°F to +315°F, +85°C to +157°C
                                                      • Decreasing: +165°F to +308°F, +74°C to +153°C


                                                      • Deadband: Approximately
                                                        • At Bottom of Range: 20°F, 11°C
                                                        • At Top of Range: 5°F, 4°C

                                                      • Probe Temperature (Maximum): +400°F, +204°C
                                                      • Probe Length / Width: 4.5" / 0.38"
                                                      • Wetted Materials:
                                                        • Temperature Probe: 300 Stainless Steel
                                                        • Capillary Tube: 25' Stainless Steel Graphite & Lubricated Glass

                                                      • Relay: DPDT
                                                      • UL, CSA
                                                        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                                      • CE Mark, NACE
                                                      Does not ship to IL, United States
                                                      28 - 35 weeks
                                                      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST Fitting, 10` Capillary view more
                                                      • Adjustable Set Point Range
                                                        • Increasing
                                                          • °F   385° to 565°
                                                          • °C   196° to 296°
                                                        • Decreasing
                                                          • °F   360° to 555°
                                                          • °C   182° to 291°
                                                      • Deadband - Approximate:
                                                        • At Bottom of Range: 25°F, 14°C
                                                        • At Top of Range: 10°F, 5°C
                                                      • Probe Temperature Maximum: 650°F, 343°C
                                                      • Probe Length / Width: 4.5" / 0.38"
                                                      • Wetted Materials
                                                        • Temperature Probe: 300 Stainless Steel
                                                        • Capillary Tube: 10' Stainless Steel Graphite & Lubricated Glass
                                                      • Relay: SPDT
                                                      • UL, CSA
                                                        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                                      • CE Mark, NACE
                                                      Does not ship to IL, United States
                                                      Contact Us

                                                      Specifications

                                                      Area Classification

                                                      • Hazardous Area

                                                      Approvals

                                                      • ATEX
                                                      • CE
                                                      • CCC
                                                      • CSA
                                                      • cUL
                                                      • Dual Seal
                                                      • GOST
                                                      • IECEx
                                                      • UL

                                                      Adjustable or Pre-Set Set Point

                                                      • Field Adjustable

                                                      Set Point °C  ▲

                                                      • Minimum: -7
                                                      • Maximum: 343

                                                      Set Point °C  ▼

                                                      • Minimum: -18
                                                      • Maximum: 338

                                                      Set Point °F  ▲

                                                      • Minimum: 20
                                                      • Maximum: 650

                                                      Set Point °F  ▼

                                                      • Minimum: 0
                                                      • Maximum: 640

                                                      Deadband, Approx. at Top of Range °C

                                                      • Minimum: 4
                                                      • Maximum: 5

                                                      Deadband, Approx. at Bottom of Range °C

                                                      • Minimum: 11
                                                      • Maximum: 14

                                                      Deadband, Approx. at Top of Range °F

                                                      • Minimum: 5
                                                      • Maximum: 10

                                                      Deadband, Approx. at Bottom of Range °F

                                                      • Minimum: 20
                                                      • Maximum: 25

                                                      Process Connection Type & Size

                                                      • 1/2"-14 NPT Male

                                                      Process Connection Material

                                                      • 300 Stainless Steel

                                                      NACE

                                                      • NACE MR 0175 / ISO 15156

                                                      O-Ring

                                                      • No O-Ring

                                                      Enclosure Rating

                                                      • IP 66
                                                      • NEMA 4
                                                      • NEMA 7
                                                      • NEMA 9
                                                      • NEMA 13

                                                      Capillary Length

                                                      • 5 ft
                                                      • 10 ft
                                                      • 15 ft
                                                      • 25 ft

                                                      Max. Probe Temp. °C

                                                      • Minimum: 93
                                                      • Maximum: 371

                                                      Max. Probe Temp. °F

                                                      • Minimum: 200
                                                      • Maximum: 700

                                                      Operating Temp. Range °C

                                                      • Minimum: -40
                                                      • Maximum: 86

                                                      Operating Temp. Range °F

                                                      • Minimum: -40
                                                      • Maximum: 186

                                                      Electrical Connection Size

                                                      • 1/2"-14 NPT Male

                                                      Electrical Termination Type

                                                      • Wire Leads 18" : 45 cm
                                                      • Wire Leads 18" : 45 cm Teflon for Low Temp
                                                      • Wire Leads 2 m : 200 cm

                                                      Electrical Contacts Form

                                                      • SPDT
                                                      • DPDT

                                                      Electrical Contacts Material

                                                      • Silver
                                                      • Gold

                                                      Voltage Electrical Rating

                                                      • 0 - 250 VAC
                                                      • 0 - 125 VDC

                                                      Ampere Rating

                                                      • 0.5 to 11 A

                                                      SIL Level

                                                      • SIL 2
                                                      • SIL 3

                                                      RoHS

                                                      Housing Material

                                                      • Aluminum
                                                      • Stainless Steel

                                                      Gender

                                                      • Male

                                                      Electrical Rating

                                                      • 1 A at 125 Vac, 50/60 Hz
                                                      • 11 A at 125/250 Vac Resistive, 5 A at 30 Vdc Resistive, 0.5 A at 125 Vdc

                                                      Conduit Connection

                                                      • M20 Explosion-proof

                                                      Process Connection

                                                      • 1/2" NPT Male

                                                      System Pressure

                                                      • bar: 86
                                                      • kPa: 8,618
                                                      • psig: 1,250

                                                      Electrical Termination Type

                                                      • 18" (45 cm) Free Leads
                                                      • 18" (45 cm) Teflon Leadwire

                                                      Enclosure, Body Material

                                                      • Aluminum
                                                      • Stainless Steel

                                                      O-Ring Material

                                                      • None

                                                      Set Point Range - Decreasing

                                                      • -18° to 338° C
                                                      • -18° to 338° C (0° to 640° F)

                                                      Proof Pressure

                                                      • bar: 103.4
                                                      • kPa: 10,342
                                                      • psig: 1,500

                                                      NACE & NIST

                                                      • NACE MR-0175: 2003

                                                      Electrical Enclosure Certification

                                                      • ATEX - SIRA Certified for Potentially Explosive Atmospheres. Models 6****Y, II 2 GD Ex d IIC, 08-ATEX-1046X. (Option Y)
                                                      • cUL, UL/CSA, Hazardous Areas, Div. 1, 2
                                                      • IECEx - SIRA Certified, SIR 10,0193X (Option Y)

                                                      Electrical Assembly

                                                      • 316 Stainless Steel
                                                      • Hermetic Seal

                                                      Deadband, Approximate - Top of Range

                                                      • -15° to -12° C (5° to 10° F)
                                                      • 4° to 5° C (39° to 41° F)

                                                      Maximum Sensor, Probe Temperature

                                                      • 93° to 371° C (200° to 700° F)

                                                      Electrical Connectors

                                                      • 1/2" NPT Male

                                                      Set Point Range - Increasing

                                                      • -7° to 343° C
                                                      • -7° to 343° C (20° to 650° F)

                                                      Adjustment Type

                                                      • Field Adjustable

                                                      Electrical Contacts

                                                      • Silver
                                                      • Gold

                                                      Sensor, Probe Material

                                                      • 300 Stainless Steel

                                                      Capillary Material

                                                      • Stainless Steel, Graphite & Lubricated Glass Fiber

                                                      Operating Temperature

                                                      • -40° to 86° C (-40° to 187° F)

                                                      Capillary Length

                                                      • 10 ft (3 m)
                                                      • 15 ft
                                                      • 25 ft
                                                      • 5 ft (1.524 m)

                                                      Approvals & Certifications

                                                      • ATEX
                                                      • CE
                                                      • CRN - Canadian Registration Number
                                                      • CRN - Alberta
                                                      • CRN - British Columbia
                                                      • CRN - Manitoba
                                                      • CRN - N.W. Territories
                                                      • CRN - Saskatchewan
                                                      • CSA
                                                      • cUL
                                                      • Dual Seal
                                                      • IEC Ex
                                                      • LVD
                                                      • PED
                                                      • RoHS
                                                      • RTN
                                                      • UL

                                                      Environmental Protection

                                                      • IP 54
                                                      • IP 66
                                                      • NEMA 4
                                                      • NEMA 7
                                                      • NEMA 9
                                                      • NEMA 13

                                                      Switch Type

                                                      • SPDT
                                                      • DPDT

                                                      Deadband, Approximate - Bottom of Range

                                                      • 11° to 14° C (52° to 57° F)
                                                      • -7° to -4° C (20° to 25° F)

                                                      Area Classification

                                                      • Hazardous Area

                                                      Applications

                                                      • Oil & Gas
                                                      • Power Generation
                                                      • Fluid Management
                                                      • Chemical Refining & Processing
                                                      • Utilities, Water Treatment & Waste
                                                      • Safety Systems