Images are representations only.

Break-to-Length RTD Sensor

Brand: Aircom Instrumentation Ltd
The Break-to-Length sensor is designed as a quick replacement element for existing thermowell assemblies. Pre-scored at 1" increments, the sensor can be "broken" to fit most applications.

A pair and a screw driver are the only tools required for the job. This unique design has no burrs or sharp edges.

For added protection the sensor come with a grommet that slips over the leads and fits into tubing.
Features
  • Lengths: 16" or 24"
  • Temperature Rating: Low Temp 204°C (399°F), High Temp 482°C (899°F)
  • 100Ω Platinum Element, ±0.1% @ 0°C
  • 316/L Stainless Steel Sheath
  • Four Conductor, Teflon or Fiberglass Insulated and Jacketed Leads
show more
The Break-to-Length sensor is designed as a quick replacement element for existing thermowell assemblies. Pre-scored at 1" increments, the sensor can be "broken" to fit most applications.

A pair and a screw driver are the only tools required for the job. This unique design has no burrs or sharp edges.

For added protection the sensor come with a grommet that slips over the leads and fits into tubing.
Features
  • Lengths: 16" or 24"
  • Temperature Rating: Low Temp 204°C (399°F), High Temp 482°C (899°F)
  • 100Ω Platinum Element, ±0.1% @ 0°C
  • 316/L Stainless Steel Sheath
  • Four Conductor, Teflon or Fiberglass Insulated and Jacketed Leads

Specifications

Element

  • 100 ohms Platinum 385 ± 0.1 %

Lead Options

  • Four Conductor, Teflon or Fiberglass Insulated & Jacketed Leads

Length

  • 16” (406.4 mm)
  • 24” (609.6 mm)

Materials of Construction

  • 316L Stainless Steel

Temperature Range

  • -200° to 850° C (-328° to 1,562° F)