Annular force transducer specially designed for application requiring a centred hole.

Features:
  • Sturdy design
  • Material: stainless steel
  • Protection: IP 67
  • Easy to install
  • CE certified for hoisting applications
  • Complete range of "CE" certified electronics, load limiters
  • Cable length: 6m
  • Available options:
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Protection IP 68
    • High service temperature (up to 180° C)
    • Amplified output (V or mA)
read more...

Agency Approvals

  • ATEX Intrinsic Safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
  • CE

Environmental Protection

  • IP67
  • IP68

Storage Temperature

  • -50 to 85° C (-58° to 185° F)

Sensitivity

  • Nominal Sensitivity: 1 to 1.5 mV/V
  • Tolerance: <±0.3% to <±0.5%

Zero Balance

  • ±0.02 mV/V

Repeatability

  • Error: <±0.1% (0.25 Model) to <±0.25% (SL - HOIST Model) of Full Scale

Resistance

  • Input/Output: 702 ±2 Ohms

Cable Length

  • 19.69 feet (6 meters)

Insulation Resistance

  • >5,000 MegaOhms

Load Limit

  • 150% (0.25 and 0.5 Model) to 200% (SL - HOIST Model) of Full Scale

Excitation Voltage

  • 10 Vdc
  • 3-12 Vdc - Nominal Range

Enclosure/Body Material

  • Stainless Steel

Applications

  • Measurement of Force and Stress
  • Weighing On Cranes

Load

  • Breaking Load: >300% to >500% of Full Scale
  • Permissible Dynamic Loading: 40% of Full scale
  • Permissible Dynamic Loading: 75% of Full scale

Linearity

  • Error: <±0.25% (0.25 Model) to 1% (SL - HOIST) of Full Scale

Service Temperature

  • -30 to 70° C (-22° to 158° F)

Capacity

  • 0.3 to 20 t