Tension load cells combining sturdiness and easiness to install.

Features:
  • Wide range of capacities: 2 t up to 100 t
  • Easy to install, compact design
  • Protection IP 66
  • Material: stainless steel (5100L), nickel plated steel (5105L)
  • Available options:
    • High service temperature (up to 180° C)
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Protection IP 68 or special for marine environment
    • Amplified output (V or mA) and digital output signal (RS-232C, RS-485, USB)
The above description encapsulates the entire product series. Specifications for individual configurations may vary depending on the selection chosen.
read more...

Selected Configuration

Model #:

5100L/5105L

Price:
Call for Pricing
Availability:
Out of Stock
Min. Qty:
1 Item

Configuration

reset configuration

Agency Approvals

  • ATEX Intrinsic Safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
  • CE

Storage Temperature

  • -50 to 85° C (-58° to 185° F)

Sensitivity

  • Nominal Sensitivity: 1 to 1.5 mV/V
  • Tolerance: <±0.5% to <±0.3%

Zero Balance

  • ±0.02 mV/V

Repeatability

  • Error: <±0.25% (SL - HOIST Model) to <±0.1% (0.25 Model) of Full Scale

Environmental Protection

  • IP66
  • IP68

Resistance

  • Input/Output: 352 ±2 Ohms

Cable Length

  • 10 to 39 feet (3 to 12 meters)

Insulation Resistance

  • >5,000 MegaOhms

Communication

  • RS-232C/RS-485
  • USB

Load Limit

  • 150% to 200% of Full Scale

Electrical Connectors

  • DIN 45322

Excitation Voltage

  • 10 Vdc

Enclosure/Body Material

  • Nickel-Plated Steel
  • Stainless Steel

Applications

  • Towing Force Measurement (Marine)
  • Weighing of Hanging Load

Load

  • >300% to >500% of Full Scale - Breaking Load

Linearity

  • Error: <±1% (SL - HOIST Model) to <±0.25% (0.25 Model) of Full Scale

Service Temperature

  • -30 to 70° C (-22° to 158° F)

Capacity

  • 2 to 100 t

Static Lateral Force

  • 10% to 150% of Full Scale