• Output: HART Protocol, 2-Wire 4-20mA
  • Input Range: -200°C to +1750°C, -328°F to +3182°F
    • Minimum Span: +10°C to +60°C, +50°F to +140°F 
  • Control: PID Capability
  • Power Supply: 
    • Bus Powered: 12 to 45 Vdc.
  • Digital Accuracy: ±0.2 to ±0.6 °C
  • Display: 4-1/2 digit numerical and 5-Character alphanumerical LCD indicator
  • Burnout: Upscale
  • Mounting Bracket: Carbon Steel or 316 Stainless Steel
  • Electrical Connection:
    • 1/2"-14 NPT
    • PG 13.5 DIN
    • M20 X 1.5
  • Damping Adjustment: User Configurable from 0 to 32 seconds
  • Power Supply Effect: ± 0.005% of calibrated span per volt
  • CSA Intrinsically Safe, Explosion Proof, Dust Ignition Proof, Non-Incendive
  • Order includes a SMAR Magnetic Screwdriver for adjustments if the LCD Display option is selected in the configuration below
read more...
TT301-0010-I3-PT4L3-BU
TT301-0010-I3-PT4L3-BU
SMAR Temperature Transmitter, TT300 Series, HART & 4 to 20 mA
$965.00
  • Base Model
  • Display

    Not Required
  • Mounting

    None
  • Sensor Connection

    3-wire
  • Sensor Type

    RTD PT100 - IEC
TT301-1010-I3-PT4L3-BU
TT301-1010-I3-PT4L3-BU
Smar Temperature Transmitter, TT301 Series
$1,194.00
  • LCD Display (1)
  • Display

    LCD Display
  • Mounting

    None
  • Sensor Connection

    3-wire
  • Sensor Type

    RTD PT100 - IEC

Agency Approvals

  • CEPEL
  • CSA
  • EXAM
  • FM
  • NEMKO ATEX

Damping Adjustment

  • User Configurable from 0 to 32 Seconds (via Digital Communication).

Operating Temperature - Display

  • -20° to 80° C (-4° to 176° F)
  • -40° to 85° C (-40° to 185° F), Without Damage

Storage Temperature

  • -40° to 100° C (-40° to 212° F)

Temperature Effect

  • mV (-10-100 mV) TC (NBS: E, J, K ,N): ±0.03% of the input mV or 0.01 mV whichever is greater -10° C variation
  • mV (-6-22 mV), TC (NBS: B, R, S, T): ±0.03% of the input mV or 0.002 mV whichever is greater -10° C variation
  • Ohms: 0 to 400 Ohms, RTD (IEC: Pt100): ±0.03% of the input resistance or 0.04 Ohms, whichever is greater

Ambient Temperature

  • -40° to 85° C (-40° to 185° F)

Humidity

  • 0 to 100% Relative Humidity

Accuracy

  • ±0.02% of span

Span and Zero Adjustments

  • Non-interactive, via local Adjustment and Digital Communication.

Digital Stability

  • ±0.1% of Reading or +0.1° C (0.18° F), whichever is greater, for 1-year for thermocouples.
  • ±0.1% of Reading or +0.1° C (0.18° F), whichever is greater, for 2 -years for RTDs

Burn-Out

  • Upscale

Electromagnetic Interference Effect

  • Approved according to IEC61326-1:2006, IEC61326-2-3:2006, IEC61000-6-4:2006, IEC61000-6-2:2005

Sensor Connection

Available sensor connection types below, 3-wire is standard.
  • 2-wire
  • 3-wire
  • 4-wire
  • Backup
  • Differential

Power Supply Effect

  • ±0.005% of Calibrated Span Per Volt

Input Power

  • HART: 12-45 Vdc.

Communication

  • HART: 2-wire, 4-20 mA according to NAMUR NE43 specification, with super-imposed Digital Communication.

Electrical Connectors

  • 1/2" NPT

Output

  • 2-wire 4-20 mA

Display

Available display types below, no display is standard.
  • 4-1/2-Digit LCD Indicator

Alarm

  • HART: In case of sensor or circuit failure, the self diagnostics drives the output to 3.6 to 21.0 mA, according to the user's choice & NAMUR NE43 specification.

Configuration

  • Software CONF401, DDCON100, or HPC301 and HPC401

Control Functions Characteristics

  • HART: PID Control, Alarm and Set Point Ramp Generator

Mounting

Available mounting types below, no mounting is standard.
  • 316 Stainless Steel Bracket and Accessories
  • Can be attached directly to the sensor. With an optional bracket can be installed on a 2" pipe or Fixed on a wall or panel.
  • Carbon Steel Bracket and Accessories

Enclosure/Body Material

  • 316 Stainless Steel IP/TYPE, 316 Stainless Steel for Saline Atmosphere IPW/TYPEX
  • Copper-Free Aluminum IPW/TYPEX, Aluminum for Saline Atmosphere IPW/TYPEX, Aluminum IP/TYPE

Enclosure Finish

  • Gray Munsell 6.5 Polyester Paint

Sensor/Probe Type

Available sensor types below, RTD PT100 - IEC is standard.
  • J Thermocouple
  • K Thermocouple
  • R Thermocouple
  • RTD PT100 - IEC
  • S Thermocouple