• Adjustable Set Point Range - Gauge:
    • Increasing: 1.0 to 10 psig, 6.89 to 68.9 kPa, 0.068 to 0.68 bar 
    • Decreasing: 0.5 to 9.5 psig, 3.45 to 65.5 kPa, 0.034 to 0.65 bar
    • Deadband: Approximately 0.5 psi, 3.45 kPa, 0.034 bar
  • Adjustable Set Point Range - Vacuum:
    • Increasing: 1.5 to 18 inches Hg, 38 to 457 mm Hg
    • Decreasing: 0.5 to 17 inches Hg, 3 to 493 mm Hg
    • Deadband: Approximately 1.0 Inches Hg, 25 mm Hg
  • System Pressure (Maximum): 500 psig, 1135.54 kPa, 10.3 bar
  • Proof Pressure: 750 psig, 1825.01 kPa, 17.2 bar 
  • Wetted Materials:
    • Pressure Port: 1/4" NPT Aluminum
    • Diaphragm: Polyimide
    • O-Ring: Buna N
  • Relay: SPDT or DPDT
  • UL, CE Mark, CRN, General Purpose 
The above description encapsulates the entire product series. Specifications for individual configurations may vary depending on the selection chosen.
read more...
604GV2
604GV2
$225.00 While Supplies Last
  • Base Model

    604GV2
  • Process Connection

    1/4"-18 Female NPT Aluminum
  • Diaphragm

    Polyimide
  • O-Ring

    Buna-N
  • Output

    SPDT
  • Electrical Contacts

    Silver
  • Agency Approvals

    UL, CE, CRN

Selected Configuration

Model #:

604GV2

Price:
$225.00 USD
Availability:
In Stock (25+)
Min. Qty:
5 Items

Configuration

reset configuration

Agency Approvals

Available agency approvals listed below, CSA is a non standard option.
  • CE
  • CRN - Alberta
  • CRN - British Columbia
  • CRN - Manitoba
  • CRN - N.W. Territories
  • CRN - Saskatchewan
  • CSA
  • cUL
  • EMC Directive
  • LVD
  • PED
  • RoHS
  • UL

Set Point - Increasing

Set Point Ranges below describe the adjustable increasing range of the entire series.
  • bar: -0.068 to 0.68
  • Inches Hg: -1.5 to 18
  • kPa: -6.9 to 68.9
  • mm Hg: -38 to 457
  • psig: -1.0 to 10

Set Point - Decreasing

Set Point Ranges below describe the adjustable increasing range of the entire series.
  • bar: -0.034 to 0.65
  • Inches Hg: -0.5 to 17
  • kPa: -3.4 to 65.5
  • mm Hg: -12.7 to 432
  • psig: -0.5 to 9.5

Adjustment Type

  • Field Adjustable

System Pressure

System Pressue below describes the range of the entire series.
  • bar: 34.5
  • kPa: 3,447
  • psig: 500

Proof Pressure

Proof Pressure below describes the range of the entire series.

  • bar: 52
  • kPa: 5,171
  • psig: 750

Operating Temperature

  • -40° to 86° C (-40° to 187° F)

Deadband, Approximate - Bottom of Range

Below describes the deadband, approximate - bottom of the range of the entire series.
  • bar: 0.034
  • Inch Hg: 1.0
  • kPa: 2.07
  • mm Hg: 25
  • psi: 0.5

Deadband, Approximate - Top of Range

Below describes the deadband, approximate - top of the range of the entire series.
  • bar: 0.034
  • Inch Hg: 1.0
  • kPa: 2.76
  • mm Hg: 25
  • psi: 0.5

Process Connection - Threaded

  • 1/4" Female NPT

Environmental Protection

  • NEMA 4, 13 / IP65, 66

Switch Type

  • DPDT
  • SPDT

Electrical Rating

Electrical Characteristics:
VOLTS AMPERES
SPDT DPDT "M" Dbl Brk"X"
Resistive Resistive Resistive
Silver Contacts
125 AC - 50/60 Hz 15 5 15
250 AC - 50/60 Hz 15 5 15
480 AC - 50/60 Hz 15 - 15
28 DC     6 5 -
125 DC     0.5 0.5 1
250 AC - 50/60 Hz 0.2 - 0.5
Gold Contacts
125 AC - 50/60 Hz 1 Max 1 Max -
30 DC     1 Max 1 Max -
SPDT (Single Pole Double Throw)
A SPDT switching element has one normally open, one normally closed and one common terminal. Three terminals mean that the switch can be wired with the circuit either normally open (N/O) or normally closed (N/C).

DPDT (Double Pole Double Throw)
A DPDT switching element has six electrical terminals. In simple terms, it is two SPDT switching elements operating simultaneously at the same settings. This type of switch can handle two independent circuits without using a relay.

Normally Closed Switching Element
A Normally Closed (NC) Switching Element is one in which the terminals are wired so that current can flow through the switching element until the plunger pin is actuated to open the circuit.
  • 1 A at 125 Vac, 50/60 Hz
  • 15 A at 125/250/480 Vac Resistive, 0.4 A at 125 DC, 0.2 A at 250 DC
  • 5 A at 125/250 Vac Resistive, 5 A at 28 Vdc, 0.5 A at 125 Vdc

Electrical Contacts

Available celectrical contact materials listed below, silver is standard.
  • Gold
  • Silver

Electrical Connectors

  • Terminal Strip - Internal

Enclosure/Body Material

  • Aluminum

Process Connection Material

  • Aluminum

O-Ring Material

Available O-ring materials listed below, Buna-N is standard.
  • Buna-N
  • Ethylene Propylene
  • Viton

Diaphragm Material

Available diaphragm materials listed below, polyimide is standard.
  • Polyimide

Standard Features

  • Internal Case Ground
  • Weatherproof