Images are representations only.

3115-ISO High-Capacity Compression Standard Ref

Brand: Sensy - Sensors & Synergy S.A.
Standard reference force transducer specially designed according to the norm ISO 376(1) (Class "1", "05" and "00").
Features
  • Broad range of capacities (up to 30 MN)
  • Complete range of load accessories
  • Protection: IP 65
  • Material: nickel plated alloy steel
  • Options:
    • Digital output RS-232C, RS-485 or USB
    • Custom made dimensions
    • ASTM E74 compliant
show more
Standard reference force transducer specially designed according to the norm ISO 376(1) (Class "1", "05" and "00").
Features
  • Broad range of capacities (up to 30 MN)
  • Complete range of load accessories
  • Protection: IP 65
  • Material: nickel plated alloy steel
  • Options:
    • Digital output RS-232C, RS-485 or USB
    • Custom made dimensions
    • ASTM E74 compliant

Specifications

Accuracy

  • Class 00
  • Class 05
  • Class 1

Applications

  • Control of Testing Machines According to ISO 7500

Approvals & Certifications

  • ISO 7500

Approvals & Certifications

  • CE

Cable Length

  • 19.96 to 39.37 feet (6 to 12 metres)

Capacity

  • 30 to 30,000 KN

Communication

  • RS-232
  • RS-485
  • USB

Electrical Connectors

  • DIN 45322 Female-Male Connector

Enclosure, Body Material

  • Nickel-Plated Alloy Steel

Environmental Protection

  • IP65

Excitation Voltage

  • 10 Vdc - Reference
  • 3-12 Vdc - Nominal Range

Insulation Resistance

  • > 5,000 megaohms at 50 V

Load

  • > 300 % of Full Scale - Breaking Load

Load Limit

  • 110 % of Full Scale - Safe Load Limit

Repeatability

  • Relative Error with Rotation: < ± 0.2 % R.O. (Class 1) to < ± 0.05 % R.O. (Class 00)
  • Relative Error without Rotation: < ± 0.1 % R.O. (Class 1) to < ± 0.025 % R.O. (Class 00)

Resistance

  • 350 to 702 ± 2 ohms - Input & Output Resistance

Sensitivity

  • 1.5 mV/V - Nominal Sensitivity

Service Temperature

  • -30° to 70° C (-22° to 158° F)

Storage Temperature

  • -50° to 85° C (-58° to 185° F)

Temperature Coefficient

  • Sensitivity: < ± 0.035 % of Full Scale/10° C (Class 1, & Class 05) to < ± 0.015 % of Full Scale/10° C (Class 00)
  • Zero Signal: < ± 0.03 % of Full Scale/10° C (Class 1, & Class 05) to < ± 0.023 % of Full Scale/10° C (Class 00)

Temperature Range

  • -10° to 45° C (14° to 113° F) - Nominal Temperature Range
  • 20° C (68° F) - Reference Temperature

Zero Balance

  • ± 0.02 mV/V

Zero Offset

  • Zero Shift after Loading: < ± 0.05 % of Full Scale (Class 1) to < ± 0.012 % of Full Scale (Class 00)