Description
The Hammer Union Pressure Transmitter is an extremely rugged pressure transmitter designed specifically for the harsh environment in the oil patch including mud logging and measurement while drilling.
Features- Ranges to 20,000 psi
- 4-20 mA or 0-5 VSC output
- 1502 or 2202 fitting
- Exceptional shock and vibration resistance
- ±0.25% accuracy of full scale
- CSA/ATEX/IEC Approved
Inventory
Displaying price & availability for Ohio, United States in USD Change Location or currency.
7 models matching criteria
APG Hammer Union with 1502 Incoloy Base, 0-10000 psi, 4-20 mA, 4-Pin Threaded MS3102
show more
- HU1502I: Hammer Union 1502 Fitting re-calibratable incoloy Pressure Transmitter
- L24: 4-20mA output
- 10K: 0 - 10,000 psis Pressure Range
- PSIS: Sealed Pressure Type
- E26: 4-Pin Threaded MS3102 (MS3102E14S-2P)
- Alternate Wiring
- Pin A = No Connection
- Pin B = -Power/Signal
- Pin C = +Power/Signal
- Pin D = Shunt Cal
- Alternate Wiring
- K0: No options (standard)
- Accuracy: ±0.25 % FSO
- Supply Voltage: 10-28 Vdc on sensor
- Temperature Range
- Compensated: -40°C to +65°C (-40°F to +150°F)
- Storage: -50C to +120°C (-58°F to +248°F)
- Operating: -40°C to +85°C (-40°F to +185°F)
- Enclosure Protection: IP67/IP65
- Certifications
- CSA/cCSAus Contract #237484
- IS: Class I, Division 1; Groups C & D
- Class I, Zone 0, AEx ia IIB T4
- Ex ia IIB T4
- Ambient: -40 - 85ºC
- ATEX: 4-20 mA
- CE 0344 EX II 1G Ex ia IIB T4 Ga
- (Ta = -40°C to +85°C)
- IECEx: 4-20 mA
- EX ia IIB T4 Ga (Ta= -40°C to +85°C)
2 In Stock
Non-Cancellable / Non-Refundable
$1,545.23USD
APG Hammer Union Pressure Transducer, 0-15,000 psi, 4-20 mA, 6-Pin Bayonet, Inconel, 1502 Welded
show more
- HU: Hammer Union Pressure Transmitter
- L24: 4-20mA output
- IS: Intrinsically Safe
- 15K: 0 - 15,000 psis Pressure Range
- PSIS: Sealed Pressure Type
- E15: 6-Pin Bayonet (PT02E10-6P)
- P36: Large Welded Hammer Union, 1502 Weco, Incoloy Base
- K0: No options (standard)
- B0: APG Label
- Accuracy: ±0.25 % FSO
- Supply Voltage: 10-30 Vdc on sensor
- Temperature Range
- Storage: -50C to +120°C (-50°F to +248°F)
- Operating: -40°C to +85°C (-40°F to +185°F)
- Enclosure Protection: IP67
- Certifications
- CSA/cCSAus Contract #237484
- IS: Class I, Division 1; Groups C & D
- Class I, Zone 0, AEx ia IIB T4
- Ex ia IIB T4
- Ambient: -40 - 85ºC
- ATEX: 4-20 mA
- CE 0344 EX II 1G Ex ia IIB T4 Ga
- (Ta = -40°C to +85°C)
- IECEx: 4-20 mA
- EX ia IIB T4 Ga (Ta= -40°C to +85°C)
3 In Stock
Non-Cancellable / Non-Refundable
$1,216.18USD
APG Hammer Union Pressure Transducer, 0-15,000psi, 4-20 mA, 6-PinBayonet SST,Inconel,1502Welded,Cage
show more
- HU1502I: Hammer Union 1502 Fitting re-calibratable incoloy Pressure Transmitter
- L24: 4-20mA output
- 15K: 0 - 15,000 psis Pressure Range
- PSIS: Sealed Pressure Type
- E27: 6-Pin Bayonet (PT02E10-6P)
- K1: With Protective Cage Assembly
- Accuracy: ±0.25 % FSO
- Supply Voltage: 10-28 Vdc on sensor
- Temperature Range
- Compensated: -40°C to +65°C (-40°F to +150°F)
- Storage: -50C to +120°C (-58°F to +248°F)
- Operating: -40°C to +85°C (-40°F to +185°F)
- Enclosure Protection: IP67/IP65
- Certifications
- CSA/cCSAus Contract #237484
- IS: Class I, Division 1; Groups C & D
- Class I, Zone 0, AEx ia IIB T4
- Ex ia IIB T4
- Ambient: -40 - 85ºC
- ATEX: 4-20 mA
- CE 0344 EX II 1G Ex ia IIB T4 Ga
- (Ta = -40°C to +85°C)
- IECEx: 4-20 mA
- EX ia IIB T4 Ga (Ta= -40°C to +85°C)
3 In Stock
Non-Cancellable / Non-Refundable
$1,347.37USD
APG Hammer Union Pressure Transducer, 0-15,000 psi, 4-20 mA, 6-Pin Bayonet, Inconel, 1502 Large
show more
- HU: Hammer Union Pressure Transmitter
- L24: 4-20mA output
- IS: Intrinsically Safe
- 15K: 0 - 15,000 psis Pressure Range
- PSIS: Sealed Pressure Type
- E15: 6-Pin Bayonet (PT02E10-6P)
- P34: Large Hammer Union, 1502 Weco, Incoloy Base
- K0: No options (standard)
- B0: APG Label
- Accuracy: ±0.25 % FSO
- Supply Voltage: 10-30 Vdc on sensor
- Temperature Range
- Storage: -50C to +120°C (-50°F to +248°F)
- Operating: -40°C to +85°C (-40°F to +185°F)
- Enclosure Protection: IP67
- Certifications
- CSA/cCSAus Contract #237484
- IS: Class I, Division 1; Groups C & D
- Class I, Zone 0, AEx ia IIB T4
- Ex ia IIB T4
- Ambient: -40 - 85ºC
- ATEX: 4-20 mA
- CE 0344 EX II 1G Ex ia IIB T4 Ga
- (Ta = -40°C to +85°C)
- IECEx: 4-20 mA
- EX ia IIB T4 Ga (Ta= -40°C to +85°C)
1 In Stock
Non-Cancellable / Non-Refundable
$1,250.24USD
APG Hammer Union with 1502 Incoloy Base, 0-10,000 psi, 4-20 mA, 4 PIN Amphenol connector
show more
- HU1502I: Hammer Union 1502 Fitting re-calibratable incoloy Pressure Transmitter
- L24: 4-20mA output
- 10K: 0 - 10,000 psis Pressure Range
- PSIS: Sealed Pressure Type
- E11: 4-Pin Threaded MS3102 (MS3102E14S-2P)
- Alternate Wiring
- Pin A = No Connection
- Pin B = -Power/Signal
- Pin C = +Power/Signal
- Pin D = Shunt Cal
- Alternate Wiring
- K0: No options (standard)
- Accuracy: ±0.25 % FSO
- Supply Voltage: 10-28 Vdc on sensor
- Temperature Range
- Compensated: -40°C to +65°C (-40°F to +150°F)
- Storage: -50C to +120°C (-58°F to +248°F)
- Operating: -40°C to +85°C (-40°F to +185°F)
- Enclosure Protection: IP67/IP65
- Certifications
- CSA/cCSAus Contract #237484
- IS: Class I, Division 1; Groups C & D
- Class I, Zone 0, AEx ia IIB T4
- Ex ia IIB T4
- Ambient: -40 - 85ºC
- ATEX: 4-20 mA
- CE 0344 EX II 1G Ex ia IIB T4 Ga
- (Ta = -40°C to +85°C)
- IECEx: 4-20 mA
- EX ia IIB T4 Ga (Ta= -40°C to +85°C)
[/li]
1 In Stock
Non-Cancellable / Non-Refundable
APG Hammer Union Pressure Transducer, 0-10k psi, 4-20 mA, 4-Pin MS3102i, 1502 Incoloy base
show more
- HU1502I: Hammer Union 1502 Fitting re-calibratable incoloy Pressure Transmitter
- L24: 4-20mA output
- 10K: 0 - 10,000 psis Pressure Range
- PSIS: Sealed Pressure Type
- E11: 4 pin Threaded MS3102
- K0: No options (standard)
- B0: APG Label
- Accuracy: ±0.25 % FSO
- Supply Voltage: 10-28 Vdc on sensor
- Temperature Range
- Compensated: -40°C to +65°C (-40°F to +150°F)
- Storage: -50C to +120°C (-58°F to +248°F)
- Operating: -40°C to +85°C (-40°F to +185°F)
- Enclosure Protection: IP67/IP65
- Certifications
- CSA/cCSAus Contract #237484
- IS: Class I, Division 1; Groups C & D
- Class I, Zone 0, AEx ia IIB T4
- Ex ia IIB T4
- Ambient: -40 - 85ºC
- ATEX: 4-20 mA
- CE 0344 EX II 1G Ex ia IIB T4 Ga
- (Ta = -40°C to +85°C)
- IECEx: 4-20 mA
- EX ia IIB T4 Ga (Ta= -40°C to +85°C)
3 - 5 weeks
Non-Cancellable / Non-Refundable
$1,327.80USD
APG Hammer Union with 1502 Incoloy Base, 0-10000 psi, 4-20 mA, 4-Pin Threaded MS3102
show more
- HU1502I: Hammer Union 1502 Fitting re-calibratable incoloy Pressure Transmitter
- L24: 4-20mA output
- 10K: 0 - 10,000 psis Pressure Range
- PSIS: Sealed Pressure Type
- E42: 4-Pin Threaded MS3102 (MS3102E14S-2P)
- Alternate Wiring
- Pin A = No Connection
- Pin B = -Power/Signal
- Pin C = +Power/Signal
- Pin D = Shunt Cal
- Alternate Wiring
- K0: No options (standard)
- Accuracy: ±0.25 % FSO
- Supply Voltage: 10-28 Vdc on sensor
- Temperature Range
- Compensated: -40°C to +65°C (-40°F to +150°F)
- Storage: -50C to +120°C (-58°F to +248°F)
- Operating: -40°C to +85°C (-40°F to +185°F)
- Enclosure Protection: IP67/IP65
- Certifications
- CSA/cCSAus Contract #237484
- IS: Class I, Division 1; Groups C & D
- Class I, Zone 0, AEx ia IIB T4
- Ex ia IIB T4
- Ambient: -40 - 85ºC
- ATEX: 4-20 mA
- CE 0344 EX II 1G Ex ia IIB T4 Ga
- (Ta = -40°C to +85°C)
- IECEx: 4-20 mA
- EX ia IIB T4 Ga (Ta= -40°C to +85°C)
3 - 5 weeks
Non-Cancellable / Non-Refundable
$1,332.14USD
Configure
Specifications
Specifications
Accuracy
- ± 0.25 % BFSL
Approvals & Certifications
- ATEX
- CSA Class I, Div. 1, Groups C, D
- IEC Ex
Burst Pressure
- 3 times Full Scale or Limit of WECO Fitting, whichever is less
Compensated Temperature
- -40° to 65° C (-40° to 150° F)
Electrical Connectors
- 4-Pin ”Mini” Style
- 4-Pin MS3102
- 5-Pin ”Mini” Style
- 6-Pin Bayonet Stainless Steel
Input Power
- Vdc: 10-30
Insulation Resistance
- > 100 megaohms at 500 Vac at 70° C (158° F)
NACE & NIST
- NACE MR-0175, ISO 15156
Operating Temperature
- -40° to 85° C (-40° to 185° F)
Output
- 0 to 5 Vdc: 110 mA Inrush Current, 3.5 mA Operating Current
- 3-30 mA Max.
Overpressure & Static Pressure Limits
- 1.5 x Full Scale or Limit of WECO Fitting, whichever is less.
Pressure Range
- bar: 0 to 1,034
- kPa: 0 to 103,421
- psig: 0 to 15,000
Process Connection - Other
- Small/Large Hammer Union 2202 WECO Fitting
- Small/Large Welded Hammer Union 1502 WECO Fitting
Shunt Calibration
- 100 % of Full Scale Output
Span & Zero Effect
- ± 0.026 % of Full Scale Output/°C (± 0.01 % of Full Scale Output/°F)
Storage Temperature
- -50° to 120° C (-58° to 248° F)
Wetted Materials
- Inconel