High capacity compression load cells.

Features:
  • High capacity compression load cells
  • Material: nickel plated steel (3115) or stainless steel (3110)
  • Protection IP 65
  • Available options (non exhaustive list):    
    • High service temperature (up to 180° C)      
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da      
    • Redundant dual Wheatstone bridge      
    • Amplified (0-10 V, 4 to 20 mA) and digital output signal (RS-232C, RS-485, USB)
  • Also available as standard reference load cells following ISO 376 (EN10002/3) (Class "0.5" and "00"’)
The above description encapsulates the entire product series. Specifications for individual configurations may vary depending on the selection chosen.
read more...

Selected Configuration

Model #:

3110/3115

Price:
Call for Pricing
Availability:
Out of Stock
Min. Qty:
1 Item

Configuration

reset configuration

Agency Approvals

  • ATEX Intrinsic Safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
  • CE

Operating Temperature

  • 180° C (356° F) - High Service Temperature

Temperature Range

  • -10° to 45° C (14° to 113° F) - Nominal

Storage Temperature

  • -50 to 85° C (-58° to 185° F)

Sensitivity

  • <±0.3% - Tolerance
  • 1.5 mV/V

Accuracy

  • 0.05% of Full Scale
  • 0.1% of Full Scale
  • 0.25% of Full Scale

Zero Balance

  • ±0.02 mV/V

Repeatability

  • Error: <±0.1% to <±0.02% of Full Scale

Environmental Protection

  • IP65

Resistance

  • Input/Output: 350 to 702 ±2 Ohms

Cable Length

  • 19 to 39 feet (6 to 12 meters)

Insulation Resistance

  • >5,000 Megaohms (50 V)

Communication

  • RS-232C
  • RS-485
  • USB

Load Limit

  • 150% of Full Scale

Electrical Connectors

  • Female/Male DIN 45322

Excitation Voltage

  • 10 Vdc
  • 3-12 Vdc - Nominal Range

Enclosure/Body Material

  • Nickel-Plated Steel (3115)
  • Stainless Steel (3110)

Applications

  • Calibration Standards
  • Force Measurement
  • Process Control
  • Weighing

Load

  • >300% of Full Scale - Breaking
  • 50% of Full Scale - Dynamic Loading

Linearity

  • Error: <±0.25% to <±0.04% of Full Scale

Service Temperature

  • -30 to 70° C (-22° to 158° F)

Capacity

  • 30 kN to 30 MN

Static Lateral Force

  • 15% of Full Scale

Temperature Coefficient

  • <±0.03 % of Full Scale/10° C (18° F) - Zero Signal
  • <±0.035 % of Full Scale/10 °C (18° F) - Sensitivity, Zero Signal
  • <±0.05 % of Full Scale/10° C (18° F) - Sensitivity