• Input Range °C: -200 to +850
    • Minimum Span °C: +10
  • Input Range °F: -328 to +1562
    • Minimum Span °F: +50
  • Power Supply: 9 - 32 Vdc, bus powered & 12 mA, Quiescent current consumption
  • Indicator: 4-1/2 digit numerical and 5-Character alphanumerical LCD indicator
  • Electrical Connection:
    • 1/2"-14 NPT
  • Sensor Type: RTD Pt100 - IEC
  • Sensor Connection: 2-Wire
  • Humidity Limits: 0 to 100% RH
  • Damping Adjustment: User Configurable from 0 to 32 seconds
  • Digital Stability: ±0.1% of reading or 0.1°C (0.18°F)
  • Temperature Effect:
    • Ohm (0 to 400Ω), RTD (Pt100): ±0.03% of the input resistance or 0.04Ω whichever is greater
  • Power Supply Effect: ± 0.005% of calibrated span per volt
  • Digital Accuracy %:
    • ±0.02% or ±0.04 Ω
  • Minimum Span Ω :
    • 4 Ω
The above description encapsulates the entire product series. Specifications for individual configurations may vary depending on the selection chosen.
read more...
TT302-10-0-I3-T4L3
TT302-10-0-I3-T4L3
$527.00
  • Input Range °C: -200 to +850
    • Minimum Span °C: +10
  • Input Range °F: -328 to +1562
    • Minimum Span °F: +50
  • Output: FoundationTM Fieldbus
  • Power Supply: 9 - 32 Vdc, bus powered & 12 mA, Quiscent current consumption
  • Indicator: 4-1/2 digit numerical and 5-Character alphanumerical LCD indicator
  • Electrical Connection:
    • 1/2"-14 NPT
  • Sensor Type: RTD Pt100 - IEC
  • Sensor Connection: 2-Wire
  • Humiditiy Limits: 0 to 100% RH
  • Damping Adjustment: User Configurable from 0 to 32 seconds
  • Digital Stability: ±0.1% of reading or 0.1°C (0.18°F)
  • Temperature Effect:
    • Ohm (0 to 400Ω), RTD (Pt100): ±0.03% of the input resistance or 0.04Ω whichever is greater
  • Power Supply Effect: ± 0.005% of calibrated span per volt
  • Digital Accuracy %:
    • ±0.02% or ±0.04 Ω
  • Minimum Span Ω :
    • 4 Ω
  • CSA Intrinsically Safe, Explosion Proof, Dust Ignition Proof, Non-Incendive
  • Order includes a SMAR Magnetic Screwdriver for adjustments if the LCD Display option is selected in the configuration below

Selected Configuration

Model #:

TT302-10-0-I3-T4L3

Price:
$527.00 USD
Availability:
In Stock (3 left)
Min. Qty:
1 Item

Configuration

reset configuration

Agency Approvals

  • CEPEL
  • CSA
  • EXAM
  • FM
  • ITK 4.6
  • NEMKO ATEX
  • NEPSI

Damping Adjustment

  • User Configurable from 0 to 32 Seconds (via Digital Communication).

Operating Temperature - Display

  • -20° to 80° C (-4° to 176° F)
  • -40° to 85° C (-40° to 185° F); without damage

Storage Temperature

  • -40° to 100° C (-40° to 212° F)

Temperature Effect

  • Ohms: 0 to 400 Ohms, RTD (IEC: Pt100): ±0.03% of the input resistance or 0.04 Ohms, whichever is greater

Ambient Temperature

  • -40° to 85° C (-40° to 185° F)

Humidity

  • 0 to 100% Relative Humidity

Accuracy

  • ±0.2° C (±0.36° F)

Span and Zero Adjustments

  • Non-interactive, via local Adjustment and Digital Communication.

Digital Stability

  • ±0.1% of Reading or +0.1° C (0.18° F), whichever is greater, for 1-year for thermocouples.
  • ±0.1% of Reading or +0.1° C (0.18° F), whichever is greater, for 2 -years for RTDs

Electromagnetic Interference Effect

  • Approved according to IEC 61326: 2002.

Environmental Protection

  • Dust Ignition-Proof
  • Explosion-Proof
  • Intrinsically Safe
  • Non-Incendive

Power Supply Effect

  • ±0.005% of Calibrated Span Per Volt

Input Power

  • Foundation Fieldbus and PROFIBUS PA: Bus powered 9-32 Vdc., Quiescent current consumption 12 mA

Electrical Connectors

  • 1/2" NPT

Output

  • Foundation Fieldbus and PROFIBUS PA: Digital Only. Complies with IEC 61158-2: 2000 (H1): 31.25 kbit/s voltage mode, bus powered.

Turn-On Time

  • Foundation fieldbus and PROFIBUS PA: Performs within specifications in less than 10 Seconds after power is applied to the transmitter.

Display

  • 4-1/2-Digit Numerical and 5-Character Alphanumerical LCD Indicator

Configuration

  • Foundation Fieldbus and PROFIBUS PA: Basic configuration may be done using the local Adjustment magnetic tool if device is supplied with display. Complete configuration is possible using configuration tools such as Syson, AMS, FieldCare and HHT375.

Control Functions Characteristics

  • Foundation Fieldbus Function Blocks: Resource, Transducer, Display Transducer, Diagnostics Transducer, Analog Input, PID Control, Enhanced PID Control, Arithmetic, Integrator, Input Selector, Signal Characterizer, Splitter, Analog Alarm, Timer, Lead Lag, Output Selector/Dynamic Limiter, Set Point Generator & Constant.

Mounting

  • Can be attached directly to the sensor. With an optional bracket can be installed on a 2" pipe or Fixed on a wall or panel.

Enclosure/Body Material

  • Aluminum (IP/TYPE)

Enclosure Finish

  • Gray Munsell 6.5 Polyester Paint