Images are representations only.

646TUE Series Temperature Switch

Brand: Custom Control Sensors
Does not ship to IA, United States
The 646TUE Series is a rugged, heavy duty temperature switch with a stainless steel capillary tube and armored jacket probe port fitting.
 
Similar to the 604 Series in design, the 646TUE Series is rated at 15 Amps and UL/CSA explosion proof, Class I, Groups A, B, C and D, and Class II Groups E, F and G certified.
 
It comes with high vibration and shock resistance utilizing Dual Snap® disc spring technology.

Features

  • Adjustable Set Point Range
    • Increasing
      • -30° to 630° F
      • -34° to 332° C
    • Decreasing
      • -39° to 624° F
      • -39° to 329° C
  • Deadband - Approximate
    • At Bottom of Range: 9° to 25° F, 3° to 14° C
    • At Top of Range: 3° to 6° F, 2° to 8° C
  • Probe Temperature Maximum: 200° to 650° F, 93° to 343° C
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel & Graphite
    • Capillary Tube: 5' Lubricated Glass Fiber
  • Relay: SPDT or DPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, Dual Seal
The 646TUE Series is a rugged, heavy duty temperature switch with a stainless steel capillary tube and armored jacket probe port fitting.
 
Similar to the 604 Series in design, the 646TUE Series is rated at 15 Amps and UL/CSA explosion proof, Class I, Groups A, B, C and D, and Class II Groups E, F and G certified.
 
It comes with high vibration and shock resistance utilizing Dual Snap® disc spring technology.

Features

  • Adjustable Set Point Range
    • Increasing
      • -30° to 630° F
      • -34° to 332° C
    • Decreasing
      • -39° to 624° F
      • -39° to 329° C
  • Deadband - Approximate
    • At Bottom of Range: 9° to 25° F, 3° to 14° C
    • At Top of Range: 3° to 6° F, 2° to 8° C
  • Probe Temperature Maximum: 200° to 650° F, 93° to 343° C
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel & Graphite
    • Capillary Tube: 5' Lubricated Glass Fiber
  • Relay: SPDT or DPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, Dual Seal
Models matching criteria: 60
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary view more
  • Adjustable Set Point Range:

    • Increasing: +275°F to +420°F, +135°C to +216°C
    • Decreasing: +256°F to +414°F, +124°C to +212°C


    • Deadband: Approximately
      • At Bottom of Range: 19°F, 11°C
      • At Top of Range: 6°F, 4°C

    • Probe Temperature (Maximum): +500°F, +260°C
    • Wetted Materials:
      • Temperature Probe: 300 Stainless Steel & Graphite
      • Capillary Tube: Lubricated Glass Fiber

    • Relay: SPDT
    • UL, CSA
      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

    • CE Mark, NACE
    Contact For Inventory
    $1,331.86 USD
    Does not ship to IA, United States
    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT view more
    • Adjustable Set Point Range:
      • Increasing: +35°F to +140°F, +2°C to +60°C
      • Decreasing: +21°F to +135°F, -6°C to +57°C
      • Deadband: Approximately
        • At Bottom of Range: 14°F, 8°C
        • At Top of Range: 5°F, 3°C
      • Probe Temperature (Maximum): +300°F, +149°C
      • Wetted Materials:
        • Temperature Probe: 300 Stainless Steel & Graphite
        • Capillary Tube: Lubricated Glass Fiber
      • Relay: DPDT
      • UL, CSA
        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
      • CE Mark, NACE
      10 - 12 weeks
      $1,384.73 USD
      Does not ship to IA, United States
      Non-Cancellable / Non-Refundable
      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT view more
      • Adjustable Set Point Range:
        • Increasing: +90°F to +210°F, +32°C to +99°C
        • Decreasing: +75°F to +195°F, +24°C to +91°C
        • Deadband: Approximately
          • At Bottom of Range: 15°F, 8°C
          • At Top of Range: 5°F, 8°C
        • Probe Temperature (Maximum): +300°F, +149°C
        • Wetted Materials:
          • Temperature Probe: 300 Stainless Steel & Graphite
          • Capillary Tube: Lubricated Glass Fiber
        • Relay: DPDT
        • UL, CSA
          • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
        • CE Mark, NACE
        10 - 12 weeks
        $1,384.73 USD
        Does not ship to IA, United States
        Non-Cancellable / Non-Refundable
        CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT view more
        • Adjustable Set Point Range:
          • Increasing: +175°F to +310°F, +79°C to +154°C
          • Decreasing: +159°F to +305°F, +71°C to +152°C
          • Deadband: Approximately
            • At Bottom of Range: 16°F, 8°C
            • At Top of Range: 5°F, 2°C
          • Probe Temperature (Maximum): +500°F, +260°C
          • Wetted Materials:
            • Temperature Probe: 300 Stainless Steel & Graphite
            • Capillary Tube: 5' Lubricated Glass Fiber
          • Relay: DPDT
          • UL, CSA
            • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
          • CE Mark, NACE
          10 - 12 weeks
          $1,384.73 USD
          Does not ship to IA, United States
          Non-Cancellable / Non-Refundable
          CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT view more
          • Adjustable Set Point Range:
            • Increasing: +275°F to +420°F, +135°C to +216°C
            • Decreasing: +256°F to +414°F, +124°C to +212°C
            • Deadband: Approximately
              • At Bottom of Range: 19°F, 11°C
              • At Top of Range: 6°F, 4°C
            • Probe Temperature (Maximum): +500°F, +260°C
            • Wetted Materials:
              • Temperature Probe: 300 Stainless Steel & Graphite
              • Capillary Tube: 5' Lubricated Glass Fiber
            • Relay: DPDT
            • UL, CSA
              • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
            • CE Mark, NACE
            10 - 12 weeks
            $1,384.73 USD
            Does not ship to IA, United States
            Non-Cancellable / Non-Refundable
            CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT view more
            • Adjustable Set Point Range:
              • Increasing: +380°F to +525°F, +193°C to +274°C
              • Decreasing: +355°F to +520°F, +179°C to +271°C
              • Deadband: Approximately
                • At Bottom of Range: 25°F, 14°C
                • At Top of Range: 5°F, 3°C
              • Probe Temperature (Maximum): +600°F, +316°C
              • Wetted Materials:
                • Temperature Probe: 300 Stainless Steel & Graphite
                • Capillary Tube: Lubricated Glass Fiber
              • Relay: DPDT
              • UL, CSA
                • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
              • CE Mark, NACE
              10 - 12 weeks
              $1,384.73 USD
              Does not ship to IA, United States
              Non-Cancellable / Non-Refundable
              CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary view more
              • Adjustable Set Point Range:

                • Increasing: -30°F to +55°F, -34°C to +13°C
                • Decreasing: -39°F to +52°F, -39°C to +11°C


                • Deadband: Approximately
                  • At Bottom of Range: 9°F, 3°C
                  • At Top of Range: 3°F, 2°C

                • Probe Temperature (Maximum): +200°F, +93°C
                • Wetted Materials:
                  • Temperature Probe: 300 Stainless Steel & Graphite
                  • Capillary Tube: 5' Lubricated Glass Fiber

                • Relay: SPDT
                • UL, CSA
                  • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                • CE Mark, NACE
                10 - 12 weeks
                $1,598.37 USD
                Does not ship to IA, United States
                CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary view more
                • Adjustable Set Point Range:

                  • Increasing: +35°F to +140°F, +2°C to +60°C
                  • Decreasing: +21°F to +135°F, -6°C to +57°C


                  • Deadband: Approximately
                    • At Bottom of Range: 14°F, 8°C
                    • At Top of Range: 5°F, 3°C

                  • Probe Temperature (Maximum): +300°F, +149°C
                  • Wetted Materials:
                    • Temperature Probe: 300 Stainless Steel & Graphite
                    • Capillary Tube: 5' Lubricated Glass Fiber

                  • Relay: SPDT
                  • UL, CSA
                    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                  • CE Mark, NACE
                  10 - 12 weeks
                  $1,598.37 USD
                  Does not ship to IA, United States
                  CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary view more
                  • Adjustable Set Point Range:

                    • Increasing: +90°F to +210°F, +32°C to +99°C
                    • Decreasing: +75°F to +195°F, +24°C to +91°C



                    • Deadband: Approximately
                      • At Bottom of Range: 15°F, 8°C
                      • At Top of Range: 5°F, 8°C

                    • Probe Temperature (Maximum): +300°F, +149°C
                    • Wetted Materials:
                      • Temperature Probe: 300 Stainless Steel & Graphite
                      • Capillary Tube: Lubricated Glass Fiber

                    • Relay: SPDT
                    • UL, CSA
                      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                    • CE Mark, NACE
                    Contact For Inventory
                    $1,598.37 USD
                    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary view more
                    • Adjustable Set Point Range:

                      • Increasing: +90°F to +210°F, +32°C to +99°C
                      • Decreasing: +75°F to +205°F, +24°C to +96°

                    • Deadband: Approximately
                      • At Bottom of Range: 15°F, 8°C
                      • At Top of Range: 5°F, 3°C

                    • Probe Temperature (Maximum): +300°F, +149°C
                    • Wetted Materials:
                      • Temperature Probe: 300 Stainless Steel & Graphite
                      • Capillary Tube: 10' Capillary, Lubricated Glass Fiber

                    • Relay: SPDT
                    • UL, CSA
                      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                    • CE Mark, NACE
                    Contact For Inventory
                    $2,580.83 USD
                    Does not ship to IA, United States
                    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary view more
                    • Adjustable Set Point Range:
                      • Increasing: +380°F to +525°F, +193°C to +274°C
                      • Decreasing: +355°F to +520°F, +179°C to +271°C
                      • Deadband: Approximately
                        • At Bottom of Range: 25°F, 14°C
                        • At Top of Range: 5°F, 3°C
                      • Probe Temperature (Maximum): +600°F, +316°C
                      • Wetted Materials:
                        • Temperature Probe: 300 Stainless Steel & Graphite
                        • Capillary Tube: Lubricated Glass Fiber
                      • Relay: SPDT
                      • UL, CSA
                        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                      • CE Mark, NACE
                      10 - 12 weeks
                      $2,635.13 USD
                      Does not ship to IA, United States
                      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary, DPDT view more
                      • Adjustable Set Point Range:

                        • Increasing: +90°F to +210°F, +32°C to +99°C
                        • Decreasing: +75°F to +195°F, +24°C to +91°C


                        • Deadband: Approximately
                          • At Bottom of Range: 15°F, 8°C
                          • At Top of Range: 5°F, 8°C

                        • Probe Temperature (Maximum): +300°F, +149°C
                        • Wetted Materials:
                          • Temperature Probe: 300 Stainless Steel & Graphite
                          • Capillary Tube: 10' Capillary, Lubricated Glass Fiber

                        • Relay: DPDT
                        • UL, CSA
                          • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                        • CE Mark, NACE
                        7 - 9 weeks
                        $2,646.56 USD
                        Does not ship to IA, United States
                        CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary view more
                        • Adjustable Set Point Range:
                          • Increasing: +35°F to +140°F, +2°C to +60°C
                          • Decreasing: +21°F to +135°F, -6°C to +57°C
                          • Deadband: Approximately
                            • At Bottom of Range: 14°F, 8°C
                            • At Top of Range: 5°F, 3°C
                          • Probe Temperature (Maximum): +300°F, +149°C
                          • Wetted Materials:
                            • Temperature Probe: 300 Stainless Steel & Graphite
                            • Capillary Tube: 10' Lubricated Glass Fiber
                          • Relay: SPDT
                          • UL, CSA
                            • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                          • CE Mark, NACE
                          10 - 12 weeks
                          $2,675.14 USD
                          Does not ship to IA, United States
                          CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary view more
                          • Adjustable Set Point Range:

                            • Increasing: +380°F to +525°F, +193°C to +274°C
                            • Decreasing: +355°F to +520°F, +179°C to +271°C


                            • Deadband: Approximately
                              • At Bottom of Range: 25°F, 14 Degrees°C
                              • At Top of Range: 5°F, 3°C

                            • Probe Temperature (Maximum): +600°F, +316°C
                            • Wetted Materials:
                              • Temperature Probe: 300 Stainless Steel & Graphite
                              • Capillary Tube: 10' Capillary, Lubricated Glass Fiber

                            • Relay: SPDT
                            • UL, CSA
                              • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                            • CE Mark, NACE
                            Contact For Inventory
                            $2,675.14 USD
                            Does not ship to IA, United States
                            CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary, DPDT view more
                            • Adjustable Set Point Range:
                              • Increasing: +35°F to +140°F, +2°C to +60°C
                              • Decreasing: +21°F to +135°F, -6°C to +57°C
                              • Deadband: Approximately
                                • At Bottom of Range: 14°F, 8°C
                                • At Top of Range: 5°F, 3°C
                              • Probe Temperature (Maximum): +300°F, +149°C
                              • Wetted Materials:
                                • Temperature Probe: 300 Stainless Steel & Graphite
                                • Capillary Tube: 15' Capillary, Lubricated Glass Fiber
                              • Relay: DPDT
                              • UL, CSA
                                • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                              • CE Mark, NACE
                              10 - 12 weeks
                              $2,675.14 USD
                              Does not ship to IA, United States
                              Non-Cancellable / Non-Refundable
                              CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary view more
                              • Adjustable Set Point Range:
                                • Increasing: +90°F to +210°F, +32°C to +99°C
                                • Decreasing: +75°F to +195°F, +24°C to +91°C
                                • Deadband: Approximately
                                  • At Bottom of Range: 15°F, 8°C
                                  • At Top of Range: 5°F, 8°C
                                • Probe Temperature (Maximum): +300°F, +149°C
                                • Wetted Materials:
                                  • Temperature Probe: 300 Stainless Steel & Graphite
                                  • Capillary Tube: Lubricated Glass Fiber
                                • Relay: SPDT
                                • UL, CSA
                                  • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                • CE Mark, NACE
                                10 - 12 weeks
                                $2,683.72 USD
                                Does not ship to IA, United States
                                Non-Cancellable / Non-Refundable
                                CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary view more
                                • Adjustable Set Point Range:
                                  • Increasing: +380°F to +525°F, +193°C to +274°C
                                  • Decreasing: +355°F to +520°F, +179°C to +271°C
                                  • Deadband: Approximately
                                    • At Bottom of Range: 25°F, 14°C
                                    • At Top of Range: 5°F, 3°C
                                  • Probe Temperature (Maximum): +600°F, +316°C
                                  • Wetted Materials:
                                    • Temperature Probe: 300 Stainless Steel & Graphite
                                    • Capillary Tube: 15' Capillary, Lubricated Glass Fiber
                                  • Relay: SPDT
                                  • UL, CSA
                                    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                  • CE Mark, NACE
                                  10 - 12 weeks
                                  $2,692.29 USD
                                  Does not ship to IA, United States
                                  Non-Cancellable / Non-Refundable
                                  CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary, DPDT view more
                                  • Adjustable Set Point Range:
                                    • Increasing: +35°F to +140°F, +2°C to +60°C
                                    • Decreasing: +21°F to +135°F, -6°C to +57°C
                                    • Deadband: Approximately
                                      • At Bottom of Range: 14°F, 8°C
                                      • At Top of Range: 5°F, 3°C
                                    • Probe Temperature (Maximum): +300°F, +149°C
                                    • Wetted Materials:
                                      • Temperature Probe: 300 Stainless Steel & Graphite
                                      • Capillary Tube: 10' Capillary, Lubricated Glass Fiber
                                    • Relay: DPDT
                                    • UL, CSA
                                      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                    • CE Mark, NACE
                                    10 - 12 weeks
                                    $2,698.01 USD
                                    Does not ship to IA, United States
                                    Non-Cancellable / Non-Refundable
                                    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary, DPDT view more
                                    • Adjustable Set Point Range:
                                      • Increasing: -30°F to +55°F, -34°C to +13°C
                                      • Decreasing: -39°F to +52°F, -39°C to +11°C
                                      • Deadband: Approximately
                                        • At Bottom of Range: 9°F, 3°C
                                        • At Top of Range: 3°F, 2°C
                                      • Probe Temperature (Maximum): +200°F, +93°C
                                      • Wetted Materials:
                                        • Temperature Probe: 300 Stainless Steel & Graphite
                                        • Capillary Tube:10' Capillary, Lubricated Glass Fiber
                                      • Relay: DPDT
                                      • UL, CSA
                                        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                      • CE Mark, NACE
                                      10 - 12 weeks
                                      $2,723.73 USD
                                      Does not ship to IA, United States
                                      Non-Cancellable / Non-Refundable
                                      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300SST&GraphiteProbe,5`Capillary,GoldContacts view more
                                      • Adjustable Set Point Range:
                                        • Increasing: +175°F to +310°F, +79°C to +154°C
                                        • Decreasing: +159°F to +305°F, +71°C to +152°C
                                        • Deadband: Approximately
                                          • At Bottom of Range: 16°F, 8°C
                                          • At Top of Range: 5°F, 2°C
                                        • Probe Temperature (Maximum): +500°F, +260°C
                                        • Wetted Materials:
                                          • Temperature Probe: 300 Stainless Steel & Graphite
                                          • Capillary Tube: Lubricated Glass Fiber
                                        • Relay: SPDT
                                        • UL, CSA
                                          • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                        • CE Mark, NACE
                                        10 - 12 weeks
                                        $2,728.02 USD
                                        Does not ship to IA, United States
                                        Non-Cancellable / Non-Refundable
                                        CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 25` Capillary view more
                                        • Adjustable Set Point Range:

                                          • Increasing: +90°F to +210°F, +32°C to +99°C
                                          • Decreasing: +75°F to +195°F, +24°C to +91°C



                                          • Deadband: Approximately
                                            • At Bottom of Range: 15°F, 8°C
                                            • At Top of Range: 5°F, 8°C

                                          • Probe Temperature (Maximum): +300°F, +149°C
                                          • Wetted Materials:
                                            • Temperature Probe: 300 Stainless Steel & Graphite
                                            • Capillary Tube: Lubricated Glass Fiber

                                          • Relay: SPDT
                                          • UL, CSA
                                            • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                          • CE Mark, NACE
                                          10 - 12 weeks
                                          $2,752.31 USD
                                          Does not ship to IA, United States
                                          Non-Cancellable / Non-Refundable
                                          CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 25` Capillary view more
                                          • Adjustable Set Point Range:
                                            • Increasing: +35°F to +140°F, +2°C to +60°C
                                            • Decreasing: +21°F to +135°F, -6°C to +57°C
                                            • Deadband: Approximately
                                              • At Bottom of Range: 14°F, 8°C
                                              • At Top of Range: 5°F, 3°C
                                            • Probe Temperature (Maximum): +300°F, +149°C
                                            • Wetted Materials:
                                              • Temperature Probe: 300 Stainless Steel & Graphite
                                              • Capillary Tube: 25' Lubricated Glass Fiber
                                            • Relay: SPDT
                                            • UL, CSA
                                              • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                            • CE Mark, NACE
                                            10 - 12 weeks
                                            $2,762.32 USD
                                            Does not ship to IA, United States
                                            Non-Cancellable / Non-Refundable
                                            CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT view more
                                            • Adjustable Set Point Range:
                                              • Increasing: -30°F to +55°F, -34°C to +13°C
                                              • Decreasing: -39°F to +52°F, -39°C to +11°C
                                            • Deadband: Approximately
                                              • At Bottom of Range: 9°F, 3°C
                                              • At Top of Range: 3°F, 2°C
                                            • Probe Temperature (Maximum): +200°F, +93°C
                                            • Wetted Materials:
                                              • Temperature Probe: 300 Stainless Steel & Graphite
                                              • Capillary Tube: 5' Lubricated Glass Fiber
                                            • Relay: DPDT
                                            • UL, CSA
                                              • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                            • CE Mark, NACE
                                            10 - 12 weeks
                                            $2,783.75 USD
                                            Does not ship to IA, United States
                                            Non-Cancellable / Non-Refundable
                                            CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 25` Capillary, DPDT view more
                                            • Adjustable Set Point Range:

                                              • Increasing: +90°F to +210°F, +32°C to +99°C
                                              • Decreasing: +75°F to +195°F, +24°C to +91°C


                                              • Deadband: Approximately
                                                • At Bottom of Range: 15°F, 8°C
                                                • At Top of Range: 5°F, 8°C

                                              • Probe Temperature (Maximum): +300°F, +149°C
                                              • Wetted Materials:
                                                • Temperature Probe: 300 Stainless Steel & Graphite
                                                • Capillary Tube: 25' Capillary, Lubricated Glass Fiber

                                              • Relay: DPDT
                                              • UL, CSA
                                                • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                              • CE Mark, NACE
                                              10 - 12 weeks
                                              $2,818.05 USD
                                              Does not ship to IA, United States
                                              Non-Cancellable / Non-Refundable
                                              CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 25` Capillary, DPDT view more
                                              • Adjustable Set Point Range:
                                                • Increasing: +35°F to +140°F, +2°C to +60°C
                                                • Decreasing: +21°F to +135°F, -6°C to +57°C

                                              • Deadband: Approximately
                                                • At Bottom of Range: 14°F, 8°C
                                                • At Top of Range: 5°F, 3°C

                                              • Probe Temperature (Maximum): +300°F, +149°C
                                              • Wetted Materials:
                                                • Temperature Probe: 300 Stainless Steel & Graphite
                                                • Capillary Tube: 25' Lubricated Glass Fiber

                                              • Relay: DPDT
                                              • UL, CSA
                                                • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                              • CE Mark, NACE
                                              10 - 12 weeks
                                              $2,828.05 USD
                                              Does not ship to IA, United States
                                              CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary view more
                                              • Adjustable Set Point Range:

                                                • Increasing: -30°F to +55°F, -34°C to +13°C
                                                • Decreasing: -39°F to +52°F, -39°C to +11°C


                                                • Deadband: Approximately
                                                  • At Bottom of Range: 9°F, 3°C
                                                  • At Top of Range: 3°F, 2°C

                                                • Probe Temperature (Maximum): +200°F, +93°C
                                                • Wetted Materials:
                                                  • Temperature Probe: 300 Stainless Steel & Graphite
                                                  • Capillary Tube: 10' Lubricated Glass Fiber

                                                • Relay: SPDT
                                                • UL, CSA
                                                  • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                                • CE Mark, NACE
                                                10 - 12 weeks
                                                $2,879.50 USD
                                                Does not ship to IA, United States
                                                CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary view more
                                                • Adjustable Set Point Range:
                                                  • Increasing: +35°F to +140°F, +2°C to +60°C
                                                  • Decreasing: +21°F to +135°F, -6°C to +57°C
                                                  • Deadband: Approximately
                                                    • At Bottom of Range: 14°F, 8°C
                                                    • At Top of Range: 5°F, 3° C
                                                  • Probe Temperature (Maximum): +300°F, +149°C
                                                  • Wetted Materials:
                                                    • Temperature Probe: 300 Stainless Steel & Graphite
                                                    • Capillary Tube: 15' Lubricated Glass Fiber
                                                  • Relay: SPDT
                                                  • UL, CSA
                                                    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                                  • CE Mark, NACE
                                                  10 - 12 weeks
                                                  $3,231.04 USD
                                                  Does not ship to IA, United States
                                                  Non-Cancellable / Non-Refundable
                                                  CCS DUAL-SNAP Temp. Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary,GoldContacts view more
                                                  • Adjustable Set Point Range:
                                                    • Increasing: +35°F to +140°F, +2°C to +60°C
                                                    • Decreasing: +21°F to +135°F, -6°C to +57°C
                                                    • Deadband: Approximately
                                                      • At Bottom of Range: 14°F, 8°C
                                                      • At Top of Range: 5°F, 3°C
                                                    • Probe Temperature (Maximum): +300°F, +149°C
                                                    • Wetted Materials:
                                                      • Temperature Probe: 300 Stainless Steel & Graphite
                                                      • Capillary Tube: 5' Lubricated Glass Fiber
                                                    • Relay: SPDT
                                                    • Contacts: Gold
                                                    • UL, CSA
                                                      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                                    • CE Mark, NACE
                                                    10 - 12 weeks
                                                    $3,418.24 USD
                                                    Does not ship to IA, United States
                                                    Non-Cancellable / Non-Refundable
                                                    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary view more
                                                    • Adjustable Set Point Range:
                                                      • Increasing: +480°F to +630°F, +249°C to +332°C
                                                      • Decreasing: +456°F to +624°F, +236°C to +329°C
                                                      • Deadband: Approximately
                                                        • At Bottom of Range: 24°F, 13°C
                                                        • At Top of Range: 6°F, 7°C
                                                      • Probe Temperature (Maximum): +650°F, +343°C
                                                      • Wetted Materials:
                                                        • Temperature Probe: 300 Stainless Steel & Graphite
                                                        • Capillary Tube: Lubricated Glass Fiber
                                                      • Relay: SPDT
                                                      • UL, CSA
                                                        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                                      • CE Mark, NACE
                                                      24 - 26 weeks
                                                      $3,536.85 USD
                                                      Does not ship to IA, United States
                                                      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary view more
                                                      • Adjustable Set Point Range
                                                        • Increasing
                                                          • °F   175° to 310°
                                                          • °C   79° to 154°
                                                        • Decreasing
                                                          • °F   159° to 305°
                                                          • °C   71° to 152°
                                                      • Deadband  Approximate
                                                        • At Bottom of Range: 16°F, 8°C
                                                        • At Top of Range: 5°F, 2°C
                                                      • Probe Temperature Maximum: 500°F, 260°C
                                                      • Wetted Materials
                                                        • Temperature Probe: 300 Stainless Steel & Graphite
                                                        • Capillary Tube: Lubricated Glass Fiber
                                                      • Relay: SPDT
                                                      • UL, CSA
                                                        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                                      • CE Mark, NACE
                                                      Does not ship to IA, United States
                                                      Contact Us
                                                      Log In to See Pricing
                                                      CCS DUAL-SNAP Temperature Switch, Hazardous Area, 1/2" NPT 300 SST & Graphite Probe, 5' Capillary
                                                      Does not ship to IA, United States
                                                      Contact For Inventory
                                                      Log In to See Pricing
                                                      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300SST & Graphite Probe,5`Capillary,ATEX/GOST view more
                                                      • Adjustable Set Point Range
                                                        • Increasing
                                                          • °F   90° to 210°
                                                          • °C   32° to 99°
                                                        • Decreasing
                                                          • °F   75° to 205°
                                                          • °C   24° to 96°
                                                      • Deadband Approximate
                                                        • At Bottom of Range: 15°F, 8°C
                                                        • At Top of Range: 5°F, 8°C
                                                      • Probe Temperature Maximum: 300°F, 149°C
                                                      • Wetted Materials  
                                                        • Temperature Probe: 300 Stainless Steel & Graphite
                                                        • Capillary Tube: Lubricated Glass Fiber
                                                      • Relay: SPDT
                                                      • ATEX
                                                        • ATEX Certified For Potentially Explosive Atmospheres Electrical Assembly Series
                                                        • 46-XXXXXXX, Models 6*****, Ex d IIC T6, Directive 94/9/EC Sira #08ATEX 1046X (Option Y)
                                                        • IECEx - SIRA Certified, SIR 10,0193X (Option Y)
                                                      • CE Mark, NACE
                                                      Does not ship to IA, United States
                                                      Contact For Inventory
                                                      Log In to See Pricing
                                                      CCS DUAL-SNAP Temp. Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary,TeflonLeads view more
                                                      • Adjustable Set Point Range:
                                                        • Increasing: -30 to +55 Degrees F, -34 to +13 Degrees C
                                                        • Decreasing: -39 to +52 Degrees F, -39 to +11 Degrees C
                                                        • Deadband: Approximately
                                                          • At Bottom of Range: 9 Degrees F, 3 Degrees C
                                                          • At Top of Range: 3 Degrees F, 2 Degrees C
                                                        • Probe Temperature (Maximum): +200 Degrees F, +93 Degrees C
                                                        • Wetted Materials:
                                                          • Temperature Probe: 300 Stainless Steel & Graphite
                                                          • O-Ring: Silicone Rubber
                                                          • Capillary Tube: 10' Lubricated Glass Fiber
                                                        • Relay: SPDT
                                                        • Wire: Teflon
                                                        • UL, CSA
                                                          • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                                        • CE Mark, NACE
                                                        Does not ship to IA, United States
                                                        10 - 12 weeks
                                                        CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 25` Capillary view more
                                                        • Adjustable Set Point Range:
                                                          • Increasing: -30°F to +55°F, -34°C to +13°C
                                                          • Decreasing: -39°F to +52°F, -39°C to +11°C
                                                          • Deadband: Approximately
                                                            • At Bottom of Range: 9°F, 3°C
                                                            • At Top of Range: 3°F, 2°C
                                                          • Probe Temperature (Maximum): +200°F, +93°C
                                                          • Wetted Materials:
                                                            • Temperature Probe: 300 Stainless Steel & Graphite
                                                            • Capillary Tube: 25' Lubricated Glass Fiber
                                                          • Relay: SPDT
                                                          • UL, CSA
                                                            • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                                          • CE Mark, NACE
                                                          Does not ship to IA, United States
                                                          10 - 12 weeks
                                                          CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary,Teflon view more
                                                          • Adjustable Set Point Range:
                                                            • Increasing: +90°F to +210°F, +32°C to +99°C
                                                            • Decreasing: +75°F to +195°F, +24°C to +91°C
                                                            • Deadband: Approximately
                                                              • At Bottom of Range: 15°F, 8°C
                                                              • At Top of Range: 5°F, 8°C
                                                            • Probe Temperature (Maximum): +300°F, +149°C
                                                            • Wetted Materials:
                                                              • Temperature Probe: 300 Stainless Steel & Graphite
                                                              • Capillary Tube: Lubricated Glass Fiber
                                                            • Relay: SPDT
                                                            • Wire: Teflon
                                                            • UL, CSA
                                                              • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                                            • CE Mark, NACE
                                                            Does not ship to IA, United States
                                                            10 - 12 weeks
                                                            CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary view more
                                                            • Adjustable Set Point Range:

                                                              • Increasing: +175°F to +310°F, +79°C to +154°C
                                                              • Decreasing: +159°F to +305°F, +71°C to +152°C



                                                              • Deadband: Approximately
                                                                • At Bottom of Range: 16°F, 8°C
                                                                • At Top of Range: 5°F, 2°C

                                                              • Probe Temperature (Maximum): +500°F, +260°C
                                                              • Wetted Materials:
                                                                • Temperature Probe: 300 Stainless Steel & Graphite
                                                                • Capillary Tube: 10' Capillary, Lubricated Glass Fiber

                                                              • Relay: SPDT
                                                              • UL, CSA
                                                                • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                                              • CE Mark, NACE
                                                              Does not ship to IA, United States
                                                              10 - 12 weeks
                                                              CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary view more
                                                              • Adjustable Set Point Range:
                                                                • Increasing: +175°F to +310°F, +79°C to +154°C
                                                                • Decreasing: +159°F to +305°F, +71°C to +152°C


                                                                • Deadband: Approximately
                                                                  • At Bottom of Range: 16°F, 8°C
                                                                  • At Top of Range: 5°F, 2°C

                                                                • Probe Temperature (Maximum): +500°F, +260°C
                                                                • Wetted Materials:
                                                                  • Temperature Probe: 300 Stainless Steel & Graphite
                                                                  • Capillary Tube: 15' Capillary, Lubricated Glass Fiber

                                                                • Relay: SPDT
                                                                • UL, CSA
                                                                  • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                                                • CE Mark, NACE
                                                                Does not ship to IA, United States
                                                                10 - 12 weeks
                                                                CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary view more
                                                                • Adjustable Set Point Range:
                                                                  • Increasing: +275°F to +420°F, +135°C to +216°C
                                                                  • Decreasing: +256°F to +414°F, +124°C to +212°C
                                                                • Deadband: Approximately
                                                                  • At Bottom of Range: 19°F, 11°C
                                                                  • At Top of Range: 6°F, 4°C
                                                                • Probe Temperature (Maximum): +500°F, +260°C
                                                                • Wetted Materials:
                                                                  • Temperature Probe: 300 Stainless Steel & Graphite
                                                                  • Capillary Tube: 15' Capillary, Lubricated Glass Fiber
                                                                • Relay: SPDT
                                                                • UL, CSA
                                                                  • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                                                • CE Mark, NACE
                                                                Does not ship to IA, United States
                                                                10 - 12 weeks
                                                                CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary view more
                                                                • Adjustable Set Point Range:
                                                                  • Increasing: +480°F to +630°F, +249°C to +332°C
                                                                  • Decreasing: +456°F to +624°F, +236°C to +329°C
                                                                  • Deadband: Approximately
                                                                    • At Bottom of Range: 24°F, 13°C
                                                                    • At Top of Range: 6°F, 7°C
                                                                  • Probe Temperature (Maximum): +650°F, +343°C
                                                                  • Wetted Materials:
                                                                    • Temperature Probe: 300 Stainless Steel & Graphite
                                                                    • Capillary Tube: 15' Capillary, Lubricated Glass Fiber
                                                                  • Relay: SPDT
                                                                  • UL, CSA
                                                                    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                                                  • CE Mark, NACE
                                                                  Does not ship to IA, United States
                                                                  10 - 12 weeks
                                                                  CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 18" Free Leads, DPDT view more
                                                                  • Adjustable Set Point Range:
                                                                    • Increasing: -30°F to +55°F, -34°C to +13°C
                                                                    • Decreasing: -39°F to +52°F, -39°C to +11°C

                                                                  • Deadband: Approximately
                                                                    • At Bottom of Range: 9°F, 3°C
                                                                    • At Top of Range: 3°F, 2°C

                                                                  • Probe Temperature (Maximum): +200°F, +93°C
                                                                  • Wetted Materials:
                                                                    • Temperature Probe: 300 Stainless Steel & Graphite
                                                                    • Capillary Tube: 5' Lubricated Glass Fiber

                                                                  • Free Leads: 18" Teflon
                                                                  • Relay: DPDT
                                                                  • UL, CSA
                                                                    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                                                  • CE Mark, NACE
                                                                  Does not ship to IA, United States
                                                                  10 - 12 weeks

                                                                  Specifications

                                                                  Area Classification

                                                                  • Hazardous Area

                                                                  Approvals

                                                                  • ATEX
                                                                  • CE
                                                                  • CCC
                                                                  • CSA
                                                                  • cUL
                                                                  • GOST
                                                                  • UL

                                                                  Adjustable or Pre-Set Set Point

                                                                  • Field Adjustable

                                                                  Set Point °C  ▲

                                                                  • Minimum: -34
                                                                  • Maximum: 332

                                                                  Set Point °C  ▼

                                                                  • Minimum: -39
                                                                  • Maximum: 329

                                                                  Set Point °F  ▲

                                                                  • Minimum: -30
                                                                  • Maximum: 630

                                                                  Set Point °F  ▼

                                                                  • Minimum: -39
                                                                  • Maximum: 624

                                                                  Deadband, Approx. at Top of Range °C

                                                                  • Minimum: 2
                                                                  • Maximum: 7

                                                                  Deadband, Approx. at Bottom of Range °C

                                                                  • Minimum: 5
                                                                  • Maximum: 14

                                                                  Deadband, Approx. at Top of Range °F

                                                                  • Minimum: 3
                                                                  • Maximum: 6

                                                                  Deadband, Approx. at Bottom of Range °F

                                                                  • Minimum: 9
                                                                  • Maximum: 25

                                                                  Process Connection Type & Size

                                                                  • 1/2"-14 NPT Male

                                                                  Process Connection Material

                                                                  • 300 Stainless Steel

                                                                  NACE

                                                                  • NACE MR 0175 / ISO 15156

                                                                  O-Ring

                                                                  • No O-Ring

                                                                  Enclosure Rating

                                                                  • IP 66
                                                                  • NEMA 4
                                                                  • NEMA 7
                                                                  • NEMA 9
                                                                  • NEMA 13

                                                                  Capillary Length

                                                                  • 5 ft
                                                                  • 10 ft
                                                                  • 15 ft
                                                                  • 25 ft

                                                                  Max. Probe Temp. °C

                                                                  • Minimum: 66
                                                                  • Maximum: 343

                                                                  Max. Probe Temp. °F

                                                                  • Minimum: 150
                                                                  • Maximum: 650

                                                                  Operating Temp. Range °C

                                                                  • Minimum: -40
                                                                  • Maximum: 86

                                                                  Operating Temp. Range °F

                                                                  • Minimum: -40
                                                                  • Maximum: 186

                                                                  Electrical Connection Size

                                                                  • 1/2"-14 NPT Male

                                                                  Electrical Termination Type

                                                                  • Wire Leads 18" : 45 cm
                                                                  • Wire Leads 18" : 45 cm Teflon for Low Temp

                                                                  Electrical Contacts Form

                                                                  • SPDT
                                                                  • DPDT
                                                                  • Double Break

                                                                  Electrical Contacts Material

                                                                  • Silver
                                                                  • Gold

                                                                  Voltage Electrical Rating

                                                                  • 0 - 250 VAC
                                                                  • 251 - 480 VAC
                                                                  • 0 - 125 VDC
                                                                  • 126 - 250 VDC

                                                                  Ampere Rating

                                                                  • 0.2 to 15 A

                                                                  SIL Level

                                                                  • SIL 2
                                                                  • SIL 3

                                                                  RoHS

                                                                  Housing Material

                                                                  • Aluminum

                                                                  Adjustment Type

                                                                  • Field Adjustable

                                                                  Deadband, Approximate - Bottom of Range

                                                                  • -13° to -4° C (9° to 25° F)
                                                                  • 5° to 14° C (41° to 57° F)

                                                                  Electrical Assembly

                                                                  • Hermetic Seal

                                                                  Set Point Range - Increasing

                                                                  • -34° to 332° C
                                                                  • -34° to 332° C (-29° to 630° F)

                                                                  Sensor, Probe Material

                                                                  • Stainless Steel & Graphite

                                                                  Electrical Termination Type

                                                                  • 18" (45 cm) Free Leads
                                                                  • 18" (45 cm) Teflon Leadwire

                                                                  Environmental Protection

                                                                  • IP 54
                                                                  • IP 66
                                                                  • NEMA 4
                                                                  • NEMA 7
                                                                  • NEMA 9
                                                                  • NEMA 13

                                                                  Electrical Contacts

                                                                  • Silver
                                                                  • Gold

                                                                  Electrical Rating

                                                                  • 1 A at 125 Vac, 50/60 Hz
                                                                  • 15 A at 125/250/480 Vac Resistive, 0.5 A at 125 Vdc, 250 A at Vdc
                                                                  • 5 A at 125/250 Vac Resisitive, 5 A at 28 Vdc, 0.5 A at 125 Vdc

                                                                  Electrical Connectors

                                                                  • 1/2" NPT Male

                                                                  Deadband, Approximate - Top of Range

                                                                  • -16° to -14° C (3° to 6° F)
                                                                  • 2° to 8° C (36° to 46° F)

                                                                  O-Ring Material

                                                                  • None

                                                                  Switch Type

                                                                  • SPDT
                                                                  • DPDT

                                                                  System Pressure

                                                                  • bar: 86
                                                                  • kPa: 8,618
                                                                  • psig: 1,250

                                                                  Electrical Certification

                                                                  • ATEX - Baseefa Certified for Potentially Explosive Atmospheres. Models 646**Y, II 2 GD Ex d IIC, Ex Tb IIIC, Baseefa 05-ATEX-0011X. (Option Y)
                                                                  • cUL, UL/CSA, Hazardous Areas, Div. 1, 2

                                                                  Proof Pressure

                                                                  • bar: 103.4
                                                                  • kPa: 10,342
                                                                  • psig: 1,500

                                                                  Set Point Range - Decreasing

                                                                  • -39° to 329° C
                                                                  • -39° to 329° C (-38° to 624° F)

                                                                  Capillary Length

                                                                  • 10 ft (3 m)
                                                                  • 15 ft
                                                                  • 25 ft
                                                                  • 5 ft (1.524 m)

                                                                  Maximum Sensor, Probe Temperature

                                                                  • 93° to 343° C (200° to 650° F)

                                                                  Operating Temperature

                                                                  • -40° to 86° C (-40° to 187° F)

                                                                  Enclosure, Body Material

                                                                  • Aluminum

                                                                  Capillary Material

                                                                  • Lubricated Glass Fiber

                                                                  Approvals & Certifications

                                                                  • ATEX
                                                                  • CE
                                                                  • CRN - Canadian Registration Number
                                                                  • CRN - Alberta
                                                                  • CRN - British Columbia
                                                                  • CRN - Manitoba
                                                                  • CRN - N.W. Territories
                                                                  • CRN - Saskatchewan
                                                                  • CSA
                                                                  • cUL
                                                                  • Dual Seal
                                                                  • EMC
                                                                  • LVD
                                                                  • PED
                                                                  • RoHS
                                                                  • RTN
                                                                  • UL

                                                                  Process Connection

                                                                  • 1/2" NPT Male

                                                                  NACE & NIST

                                                                  • NACE MR-0175: 2003

                                                                  Area Classification

                                                                  • Hazardous Area

                                                                  Applications

                                                                  • Oil & Gas
                                                                  • Power Generation
                                                                  • Fluid Management[
                                                                  • Chemical Refining and Processing
                                                                  • Manufacturing Process
                                                                  • Utilities, Water Treatment and Waste
                                                                  • Safety Systems