Description
The 646TUE Series is a rugged, heavy duty temperature switch with a stainless steel capillary tube and armored jacket probe port fitting.
Similar to the 604 Series in design, the 646TUE Series is rated at 15 Amps and UL/CSA explosion proof, Class I, Groups A, B, C and D, and Class II Groups E, F and G certified.
It comes with high vibration and shock resistance utilizing Dual Snap® disc spring technology.
Features
- Adjustable Set Point Range
- Increasing
- -30° to 630° F
- -34° to 332° C
- Decreasing
- -39° to 624° F
- -39° to 329° C
- Increasing
- Deadband - Approximate
- At Bottom of Range: 9° to 25° F, 3° to 14° C
- At Top of Range: 3° to 6° F, 2° to 8° C
- Probe Temperature - Maximum: 200° to 650° F, 93° to 343° C
- Wetted Materials
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 5' Lubricated Glass Fiber
- Relay: SPDT or DPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, Dual Seal
Inventory
Displaying prices & availability for Iowa, United States 50307 in USD. Change location or currency.
Models matching criteria: 60
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary view more
- Adjustable Set Point Range:
- Increasing: +275°F to +420°F, +135°C to +216°C
- Decreasing: +256°F to +414°F, +124°C to +212°C
- Deadband: Approximately
- At Bottom of Range: 19°F, 11°C
- At Top of Range: 6°F, 4°C
- Probe Temperature (Maximum): +500°F, +260°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
Contact For Inventory
$1,331.86 USD
Does not ship to IA, United States
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT view more
- Adjustable Set Point Range:
- Increasing: +35°F to +140°F, +2°C to +60°C
- Decreasing: +21°F to +135°F, -6°C to +57°C
- Deadband: Approximately
- At Bottom of Range: 14°F, 8°C
- At Top of Range: 5°F, 3°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: Lubricated Glass Fiber
- Relay: DPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$1,384.73 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT view more
- Adjustable Set Point Range:
- Increasing: +90°F to +210°F, +32°C to +99°C
- Decreasing: +75°F to +195°F, +24°C to +91°C
- Deadband: Approximately
- At Bottom of Range: 15°F, 8°C
- At Top of Range: 5°F, 8°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: Lubricated Glass Fiber
- Relay: DPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$1,384.73 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT view more
- Adjustable Set Point Range:
- Increasing: +175°F to +310°F, +79°C to +154°C
- Decreasing: +159°F to +305°F, +71°C to +152°C
- Deadband: Approximately
- At Bottom of Range: 16°F, 8°C
- At Top of Range: 5°F, 2°C
- Probe Temperature (Maximum): +500°F, +260°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 5' Lubricated Glass Fiber
- Relay: DPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$1,384.73 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT view more
- Adjustable Set Point Range:
- Increasing: +275°F to +420°F, +135°C to +216°C
- Decreasing: +256°F to +414°F, +124°C to +212°C
- Deadband: Approximately
- At Bottom of Range: 19°F, 11°C
- At Top of Range: 6°F, 4°C
- Probe Temperature (Maximum): +500°F, +260°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 5' Lubricated Glass Fiber
- Relay: DPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$1,384.73 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT view more
- Adjustable Set Point Range:
- Increasing: +380°F to +525°F, +193°C to +274°C
- Decreasing: +355°F to +520°F, +179°C to +271°C
- Deadband: Approximately
- At Bottom of Range: 25°F, 14°C
- At Top of Range: 5°F, 3°C
- Probe Temperature (Maximum): +600°F, +316°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: Lubricated Glass Fiber
- Relay: DPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$1,384.73 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary view more
- Adjustable Set Point Range:
- Increasing: -30°F to +55°F, -34°C to +13°C
- Decreasing: -39°F to +52°F, -39°C to +11°C
- Deadband: Approximately
- At Bottom of Range: 9°F, 3°C
- At Top of Range: 3°F, 2°C
- Probe Temperature (Maximum): +200°F, +93°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 5' Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$1,598.37 USD
Does not ship to IA, United States
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary view more
- Adjustable Set Point Range:
- Increasing: +35°F to +140°F, +2°C to +60°C
- Decreasing: +21°F to +135°F, -6°C to +57°C
- Deadband: Approximately
- At Bottom of Range: 14°F, 8°C
- At Top of Range: 5°F, 3°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 5' Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$1,598.37 USD
Does not ship to IA, United States
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary view more
- Adjustable Set Point Range:
- Increasing: +90°F to +210°F, +32°C to +99°C
- Decreasing: +75°F to +195°F, +24°C to +91°C
- Deadband: Approximately
- At Bottom of Range: 15°F, 8°C
- At Top of Range: 5°F, 8°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
Contact For Inventory
$1,598.37 USD
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary view more
- Adjustable Set Point Range:
- Increasing: +90°F to +210°F, +32°C to +99°C
- Decreasing: +75°F to +205°F, +24°C to +96°
- Deadband: Approximately
- At Bottom of Range: 15°F, 8°C
- At Top of Range: 5°F, 3°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 10' Capillary, Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
Contact For Inventory
$2,580.83 USD
Does not ship to IA, United States
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary view more
- Adjustable Set Point Range:
- Increasing: +380°F to +525°F, +193°C to +274°C
- Decreasing: +355°F to +520°F, +179°C to +271°C
- Deadband: Approximately
- At Bottom of Range: 25°F, 14°C
- At Top of Range: 5°F, 3°C
- Probe Temperature (Maximum): +600°F, +316°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$2,635.13 USD
Does not ship to IA, United States
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary, DPDT view more
- Adjustable Set Point Range:
- Increasing: +90°F to +210°F, +32°C to +99°C
- Decreasing: +75°F to +195°F, +24°C to +91°C
- Deadband: Approximately
- At Bottom of Range: 15°F, 8°C
- At Top of Range: 5°F, 8°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 10' Capillary, Lubricated Glass Fiber
- Relay: DPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
7 - 9 weeks
$2,646.56 USD
Does not ship to IA, United States
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary view more
- Adjustable Set Point Range:
- Increasing: +35°F to +140°F, +2°C to +60°C
- Decreasing: +21°F to +135°F, -6°C to +57°C
- Deadband: Approximately
- At Bottom of Range: 14°F, 8°C
- At Top of Range: 5°F, 3°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 10' Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$2,675.14 USD
Does not ship to IA, United States
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary view more
- Adjustable Set Point Range:
- Increasing: +380°F to +525°F, +193°C to +274°C
- Decreasing: +355°F to +520°F, +179°C to +271°C
- Deadband: Approximately
- At Bottom of Range: 25°F, 14 Degrees°C
- At Top of Range: 5°F, 3°C
- Probe Temperature (Maximum): +600°F, +316°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 10' Capillary, Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
Contact For Inventory
$2,675.14 USD
Does not ship to IA, United States
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary, DPDT view more
- Adjustable Set Point Range:
- Increasing: +35°F to +140°F, +2°C to +60°C
- Decreasing: +21°F to +135°F, -6°C to +57°C
- Deadband: Approximately
- At Bottom of Range: 14°F, 8°C
- At Top of Range: 5°F, 3°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 15' Capillary, Lubricated Glass Fiber
- Relay: DPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$2,675.14 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary view more
- Adjustable Set Point Range:
- Increasing: +90°F to +210°F, +32°C to +99°C
- Decreasing: +75°F to +195°F, +24°C to +91°C
- Deadband: Approximately
- At Bottom of Range: 15°F, 8°C
- At Top of Range: 5°F, 8°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$2,683.72 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary view more
- Adjustable Set Point Range:
- Increasing: +380°F to +525°F, +193°C to +274°C
- Decreasing: +355°F to +520°F, +179°C to +271°C
- Deadband: Approximately
- At Bottom of Range: 25°F, 14°C
- At Top of Range: 5°F, 3°C
- Probe Temperature (Maximum): +600°F, +316°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 15' Capillary, Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$2,692.29 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary, DPDT view more
- Adjustable Set Point Range:
- Increasing: +35°F to +140°F, +2°C to +60°C
- Decreasing: +21°F to +135°F, -6°C to +57°C
- Deadband: Approximately
- At Bottom of Range: 14°F, 8°C
- At Top of Range: 5°F, 3°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 10' Capillary, Lubricated Glass Fiber
- Relay: DPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$2,698.01 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary, DPDT view more
- Adjustable Set Point Range:
- Increasing: -30°F to +55°F, -34°C to +13°C
- Decreasing: -39°F to +52°F, -39°C to +11°C
- Deadband: Approximately
- At Bottom of Range: 9°F, 3°C
- At Top of Range: 3°F, 2°C
- Probe Temperature (Maximum): +200°F, +93°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube:10' Capillary, Lubricated Glass Fiber
- Relay: DPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$2,723.73 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300SST&GraphiteProbe,5`Capillary,GoldContacts view more
- Adjustable Set Point Range:
- Increasing: +175°F to +310°F, +79°C to +154°C
- Decreasing: +159°F to +305°F, +71°C to +152°C
- Deadband: Approximately
- At Bottom of Range: 16°F, 8°C
- At Top of Range: 5°F, 2°C
- Probe Temperature (Maximum): +500°F, +260°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$2,728.02 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 25` Capillary view more
- Adjustable Set Point Range:
- Increasing: +90°F to +210°F, +32°C to +99°C
- Decreasing: +75°F to +195°F, +24°C to +91°C
- Deadband: Approximately
- At Bottom of Range: 15°F, 8°C
- At Top of Range: 5°F, 8°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$2,752.31 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 25` Capillary view more
- Adjustable Set Point Range:
- Increasing: +35°F to +140°F, +2°C to +60°C
- Decreasing: +21°F to +135°F, -6°C to +57°C
- Deadband: Approximately
- At Bottom of Range: 14°F, 8°C
- At Top of Range: 5°F, 3°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 25' Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$2,762.32 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT view more
- Adjustable Set Point Range:
- Increasing: -30°F to +55°F, -34°C to +13°C
- Decreasing: -39°F to +52°F, -39°C to +11°C
- Deadband: Approximately
- At Bottom of Range: 9°F, 3°C
- At Top of Range: 3°F, 2°C
- Probe Temperature (Maximum): +200°F, +93°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 5' Lubricated Glass Fiber
- Relay: DPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$2,783.75 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 25` Capillary, DPDT view more
- Adjustable Set Point Range:
- Increasing: +90°F to +210°F, +32°C to +99°C
- Decreasing: +75°F to +195°F, +24°C to +91°C
- Deadband: Approximately
- At Bottom of Range: 15°F, 8°C
- At Top of Range: 5°F, 8°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 25' Capillary, Lubricated Glass Fiber
- Relay: DPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$2,818.05 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 25` Capillary, DPDT view more
- Adjustable Set Point Range:
- Increasing: +35°F to +140°F, +2°C to +60°C
- Decreasing: +21°F to +135°F, -6°C to +57°C
- Deadband: Approximately
- At Bottom of Range: 14°F, 8°C
- At Top of Range: 5°F, 3°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 25' Lubricated Glass Fiber
- Relay: DPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$2,828.05 USD
Does not ship to IA, United States
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary view more
- Adjustable Set Point Range:
- Increasing: -30°F to +55°F, -34°C to +13°C
- Decreasing: -39°F to +52°F, -39°C to +11°C
- Deadband: Approximately
- At Bottom of Range: 9°F, 3°C
- At Top of Range: 3°F, 2°C
- Probe Temperature (Maximum): +200°F, +93°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 10' Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$2,879.50 USD
Does not ship to IA, United States
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary view more
- Adjustable Set Point Range:
- Increasing: +35°F to +140°F, +2°C to +60°C
- Decreasing: +21°F to +135°F, -6°C to +57°C
- Deadband: Approximately
- At Bottom of Range: 14°F, 8°C
- At Top of Range: 5°F, 3° C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 15' Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$3,231.04 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temp. Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary,GoldContacts view more
- Adjustable Set Point Range:
- Increasing: +35°F to +140°F, +2°C to +60°C
- Decreasing: +21°F to +135°F, -6°C to +57°C
- Deadband: Approximately
- At Bottom of Range: 14°F, 8°C
- At Top of Range: 5°F, 3°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 5' Lubricated Glass Fiber
- Relay: SPDT
- Contacts: Gold
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
10 - 12 weeks
$3,418.24 USD
Does not ship to IA, United States
Non-Cancellable / Non-Refundable
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary view more
- Adjustable Set Point Range:
- Increasing: +480°F to +630°F, +249°C to +332°C
- Decreasing: +456°F to +624°F, +236°C to +329°C
- Deadband: Approximately
- At Bottom of Range: 24°F, 13°C
- At Top of Range: 6°F, 7°C
- Probe Temperature (Maximum): +650°F, +343°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
24 - 26 weeks
$3,536.85 USD
Does not ship to IA, United States
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary view more
- Adjustable Set Point Range
- Increasing
- °F 175° to 310°
- °C 79° to 154°
- Decreasing
- °F 159° to 305°
- °C 71° to 152°
- Increasing
- Deadband - Approximate
- At Bottom of Range: 16°F, 8°C
- At Top of Range: 5°F, 2°C
- Probe Temperature - Maximum: 500°F, 260°C
- Wetted Materials
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
Does not ship to IA, United States
Contact Us
Log In to See Pricing
CCS DUAL-SNAP Temperature Switch, Hazardous Area, 1/2" NPT 300 SST & Graphite Probe, 5' Capillary
Does not ship to IA, United States
Contact For Inventory
Log In to See Pricing
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300SST & Graphite Probe,5`Capillary,ATEX/GOST view more
- Adjustable Set Point Range
- Increasing
- °F 90° to 210°
- °C 32° to 99°
- Decreasing
- °F 75° to 205°
- °C 24° to 96°
- Increasing
- Deadband - Approximate
- At Bottom of Range: 15°F, 8°C
- At Top of Range: 5°F, 8°C
- Probe Temperature - Maximum: 300°F, 149°C
- Wetted Materials
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: Lubricated Glass Fiber
- Relay: SPDT
- ATEX
- ATEX Certified For Potentially Explosive Atmospheres Electrical Assembly Series
- 46-XXXXXXX, Models 6*****, Ex d IIC T6, Directive 94/9/EC Sira #08ATEX 1046X (Option Y)
- IECEx - SIRA Certified, SIR 10,0193X (Option Y)
- CE Mark, NACE
Does not ship to IA, United States
Contact For Inventory
Log In to See Pricing
CCS DUAL-SNAP Temp. Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary,TeflonLeads view more
- Adjustable Set Point Range:
- Increasing: -30 to +55 Degrees F, -34 to +13 Degrees C
- Decreasing: -39 to +52 Degrees F, -39 to +11 Degrees C
- Deadband: Approximately
- At Bottom of Range: 9 Degrees F, 3 Degrees C
- At Top of Range: 3 Degrees F, 2 Degrees C
- Probe Temperature (Maximum): +200 Degrees F, +93 Degrees C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- O-Ring: Silicone Rubber
- Capillary Tube: 10' Lubricated Glass Fiber
- Relay: SPDT
- Wire: Teflon
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
Does not ship to IA, United States
10 - 12 weeks
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 25` Capillary view more
- Adjustable Set Point Range:
- Increasing: -30°F to +55°F, -34°C to +13°C
- Decreasing: -39°F to +52°F, -39°C to +11°C
- Deadband: Approximately
- At Bottom of Range: 9°F, 3°C
- At Top of Range: 3°F, 2°C
- Probe Temperature (Maximum): +200°F, +93°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 25' Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
Does not ship to IA, United States
10 - 12 weeks
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary,Teflon view more
- Adjustable Set Point Range:
- Increasing: +90°F to +210°F, +32°C to +99°C
- Decreasing: +75°F to +195°F, +24°C to +91°C
- Deadband: Approximately
- At Bottom of Range: 15°F, 8°C
- At Top of Range: 5°F, 8°C
- Probe Temperature (Maximum): +300°F, +149°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: Lubricated Glass Fiber
- Relay: SPDT
- Wire: Teflon
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
Does not ship to IA, United States
10 - 12 weeks
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary view more
- Adjustable Set Point Range:
- Increasing: +175°F to +310°F, +79°C to +154°C
- Decreasing: +159°F to +305°F, +71°C to +152°C
- Deadband: Approximately
- At Bottom of Range: 16°F, 8°C
- At Top of Range: 5°F, 2°C
- Probe Temperature (Maximum): +500°F, +260°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 10' Capillary, Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
Does not ship to IA, United States
10 - 12 weeks
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary view more
- Adjustable Set Point Range:
- Increasing: +175°F to +310°F, +79°C to +154°C
- Decreasing: +159°F to +305°F, +71°C to +152°C
- Deadband: Approximately
- At Bottom of Range: 16°F, 8°C
- At Top of Range: 5°F, 2°C
- Probe Temperature (Maximum): +500°F, +260°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 15' Capillary, Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
Does not ship to IA, United States
10 - 12 weeks
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary view more
- Adjustable Set Point Range:
- Increasing: +275°F to +420°F, +135°C to +216°C
- Decreasing: +256°F to +414°F, +124°C to +212°C
- Deadband: Approximately
- At Bottom of Range: 19°F, 11°C
- At Top of Range: 6°F, 4°C
- Probe Temperature (Maximum): +500°F, +260°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 15' Capillary, Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
Does not ship to IA, United States
10 - 12 weeks
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary view more
- Adjustable Set Point Range:
- Increasing: +480°F to +630°F, +249°C to +332°C
- Decreasing: +456°F to +624°F, +236°C to +329°C
- Deadband: Approximately
- At Bottom of Range: 24°F, 13°C
- At Top of Range: 6°F, 7°C
- Probe Temperature (Maximum): +650°F, +343°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 15' Capillary, Lubricated Glass Fiber
- Relay: SPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
Does not ship to IA, United States
10 - 12 weeks
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 18" Free Leads, DPDT view more
- Adjustable Set Point Range:
- Increasing: -30°F to +55°F, -34°C to +13°C
- Decreasing: -39°F to +52°F, -39°C to +11°C
- Deadband: Approximately
- At Bottom of Range: 9°F, 3°C
- At Top of Range: 3°F, 2°C
- Probe Temperature (Maximum): +200°F, +93°C
- Wetted Materials:
- Temperature Probe: 300 Stainless Steel & Graphite
- Capillary Tube: 5' Lubricated Glass Fiber
- Free Leads: 18" Teflon
- Relay: DPDT
- UL, CSA
- Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
- CE Mark, NACE
Does not ship to IA, United States
10 - 12 weeks
Configure
Specifications
Specifications
Area Classification
- Hazardous Area
Approvals
- ATEX
- CE
- CCC
- CSA
- cUL
- GOST
- UL
Adjustable or Pre-Set Set Point
- Field Adjustable
Set Point °C ▲
- Minimum: -34
- Maximum: 332
Set Point °C ▼
- Minimum: -39
- Maximum: 329
Set Point °F ▲
- Minimum: -30
- Maximum: 630
Set Point °F ▼
- Minimum: -39
- Maximum: 624
Deadband, Approx. at Top of Range °C
- Minimum: 2
- Maximum: 7
Deadband, Approx. at Bottom of Range °C
- Minimum: 5
- Maximum: 14
Deadband, Approx. at Top of Range °F
- Minimum: 3
- Maximum: 6
Deadband, Approx. at Bottom of Range °F
- Minimum: 9
- Maximum: 25
Process Connection Type & Size
- 1/2"-14 NPT Male
Process Connection Material
- 300 Stainless Steel
NACE
- NACE MR 0175 / ISO 15156
O-Ring
- No O-Ring
Enclosure Rating
- IP 66
- NEMA 4
- NEMA 7
- NEMA 9
- NEMA 13
Capillary Length
- 5 ft
- 10 ft
- 15 ft
- 25 ft
Max. Probe Temp. °C
- Minimum: 66
- Maximum: 343
Max. Probe Temp. °F
- Minimum: 150
- Maximum: 650
Operating Temp. Range °C
- Minimum: -40
- Maximum: 86
Operating Temp. Range °F
- Minimum: -40
- Maximum: 186
Electrical Connection Size
- 1/2"-14 NPT Male
Electrical Termination Type
- Wire Leads 18" : 45 cm
- Wire Leads 18" : 45 cm Teflon for Low Temp
Electrical Contacts Form
- SPDT
- DPDT
- Double Break
Electrical Contacts Material
- Silver
- Gold
Voltage Electrical Rating
- 0 - 250 VAC
- 251 - 480 VAC
- 0 - 125 VDC
- 126 - 250 VDC
Ampere Rating
- 0.2 to 15 A
SIL Level
- SIL 2
- SIL 3
RoHS
Housing Material
- Aluminum
Adjustment Type
- Field Adjustable
Deadband, Approximate - Bottom of Range
- -13° to -4° C (9° to 25° F)
- 5° to 14° C (41° to 57° F)
Electrical Assembly
- Hermetic Seal
Set Point Range - Increasing
- -34° to 332° C
- -34° to 332° C (-29° to 630° F)
Sensor, Probe Material
- Stainless Steel & Graphite
Electrical Termination Type
- 18" (45 cm) Free Leads
- 18" (45 cm) Teflon Leadwire
Environmental Protection
- IP 54
- IP 66
- NEMA 4
- NEMA 7
- NEMA 9
- NEMA 13
Electrical Contacts
- Silver
- Gold
Electrical Rating
- 1 A at 125 Vac, 50/60 Hz
- 15 A at 125/250/480 Vac Resistive, 0.5 A at 125 Vdc, 250 A at Vdc
- 5 A at 125/250 Vac Resisitive, 5 A at 28 Vdc, 0.5 A at 125 Vdc
Electrical Connectors
- 1/2" NPT Male
Deadband, Approximate - Top of Range
- -16° to -14° C (3° to 6° F)
- 2° to 8° C (36° to 46° F)
O-Ring Material
- None
Switch Type
- SPDT
- DPDT
System Pressure
- bar: 86
- kPa: 8,618
- psig: 1,250
Electrical Certification
- ATEX - Baseefa Certified for Potentially Explosive Atmospheres. Models 646**Y, II 2 GD Ex d IIC, Ex Tb IIIC, Baseefa 05-ATEX-0011X. (Option Y)
- cUL, UL/CSA, Hazardous Areas, Div. 1, 2
Proof Pressure
- bar: 103.4
- kPa: 10,342
- psig: 1,500
Set Point Range - Decreasing
- -39° to 329° C
- -39° to 329° C (-38° to 624° F)
Capillary Length
- 10 ft (3 m)
- 15 ft
- 25 ft
- 5 ft (1.524 m)
Maximum Sensor, Probe Temperature
- 93° to 343° C (200° to 650° F)
Operating Temperature
- -40° to 86° C (-40° to 187° F)
Enclosure, Body Material
- Aluminum
Capillary Material
- Lubricated Glass Fiber
Approvals & Certifications
- ATEX
- CE
- CRN - Canadian Registration Number
- CRN - Alberta
- CRN - British Columbia
- CRN - Manitoba
- CRN - N.W. Territories
- CRN - Saskatchewan
- CSA
- cUL
- Dual Seal
- EMC
- LVD
- PED
- RoHS
- RTN
- UL
Process Connection
- 1/2" NPT Male
NACE & NIST
- NACE MR-0175: 2003
Area Classification
- Hazardous Area
Applications
Applications
- Oil & Gas
- Power Generation
- Fluid Management[
- Chemical Refining and Processing
- Manufacturing Process
- Utilities, Water Treatment and Waste
- Safety Systems
Documentation
Documentation
Data Sheets
Product Manuals
Certifications & Approvals
- Certifications & Approvals - CCS 646 Dec 2005 pdf 96 KB
- Certifications & Approvals - CCS 646 Feb 2005 pdf 164 KB
- Certifications & Approvals - CCS 646 Jan 2007 pdf 92 KB
- Certifications & Approvals - CCS Approval Matrix pdf 34 KB
- Certifications & Approvals - CCS CE Certificate of Declaration pdf 225 KB
- Certifications & Approvals - CCS CRN Approval - Alberta pdf 126 KB
- Certifications & Approvals - CCS CRN Approval - BC pdf 67 KB
- Certifications & Approvals - CCS CRN Approval - Manitoba pdf 79 KB
- Certifications & Approvals - CCS CRN Approval - NWT pdf 87 KB
- Certifications & Approvals - CCS CRN Approval - Saskatchewan pdf 263 KB
- Certifications & Approvals - CCS CSA Certification Record - Hazardous pdf 32 KB
- Certifications & Approvals - CCS EMC Directive pdf 30 KB
- Certifications & Approvals - CCS LVD - Low Voltage Directive pdf 98 KB
- Certifications & Approvals - CCS NACE Declaration 2013 pdf 114 KB
- Certifications & Approvals - CCS PED 2011 pdf 94 KB
- Certifications & Approvals - CCS RoHS/REACH 2012 pdf 278 KB