PD6938 VantageView+ NEMA 4X Pulse Input Flow Rate/Totalizer
Does not ship to IL, United States
Description
The Vantageview PD6730 is a plastic, field-mounted flow rate/totalizer that can display flow rate and total from a pulse output flowmeter.
Its display has a five digit upper line for rate, a seven alpha-numeric character lower line for total, and comes standard with a backlight.
The PD6730 is built in a NEMA 4X and IP65 rated plastic enclosure which can stand up to even the harshest environmental conditions. It can be powered from an included battery or a 24 VDC external power supply.
Some features that really make the PD6730 stand out are its automatic unit conversions from flowmeter k-factor units, ability to log up to 1024 data points, and SafeTouch® through-window buttons.
These buttons allow the PD6730 to be programmed and operated through the cover window, thus eliminating the need to remove the cover in dirty or wet environments.
Features
- Pulse, Open Collector, NPN, PNP, TTL, Switch Contact, Sine Wave - Coil, Square Wave, Opto-Isolated Inputs
- NEMA 4X, IP65 Plastic Enclosure for Safe Areas
- 5-Digit 0.7" / 17.8 mm Top Display for Rate or Total
- 7 Alphanumeric Character 0.4" / 10.2 mm Lower Display for Rate, Total, Grand Total, Units, and Tag
- 13-Digit Totalizer with Total Overflow Feature
- SafeTouch® Through-Window Button Programming
- Isolated 4-20 mA Output for Rate, Total, or Grand Total
- Two Isolated Open Collector Pulse Outputs, Up to 5 kHz
- Battery, DC, or Output Loop-Powered Models
- Gate Function for Rate Display of Slow Pulse Rates
- K-Factor, Scaling, or Live Input Calibration with 32-Point Linearization
- Automatic Rate, Total, and Grand Total Unit Conversions
- Password Protection
- Backlight Standard on All Models
- On-Board Data Logging
- Modbus® Communications RS-485 Option
- Flanges for Wall or Pipe Mounting
- Operates from -40 to 75°C
Configure
Specifications
Specifications
Display
- Top: Five digits (0 to 99,999), 0.7" (17.8 mm) high, 7-segment, automatic lead zero blanking
- Bottom: Seven alphanumeric characters, 0.4" (10.2 mm) high, 14-segment, automatic lead zero blanking
- Symbols: Total, grand total, battery power/low battery, high alarm, low alarm, SafeTouch button sleep mode/disable, password lock
Display Update Rate
- Ambient > -20°C: 1 Update/Second
- Ambient < -20°C: 1 Update/10 Seconds
Programming Method
- Four SafeTouch through-window buttons when cover is installed. Four internal pushbuttons when cover is removed. Free MeterView EX software
Enclosure
- NEMA 4X, IP66 plastic field enclosure, polycarbonate with UV stabilizer
- Color: grey
- Window: Clear polycarbonate with UV stabilizer
- Three 3/4" NPT threaded conduit openings
- Two 3/4" NPT plastic conduit plugs included
Environmental
- Relative Humidity: 0 to 90% non-condensing
- Printed circuit boards are conformally coated
- Operating/Storage: -40° to 75° C (-40° to 167° F)
Power Options
- 9-30 VDC Powered, 2.2 W max
- 4-20 mA Output Powered, 30 VDC max
- Battery Power
- 9-30 VDC Powered with Battery Backup
- 4-20 mA Output Powered with Battery Backup
Mounting
- May be mounted directly to conduit
- Two slotted flanges for wall mounting or NPS 1-1/2" to 2-1/2" or DN 40 to 65 mm pipe mounting
Isolation
- All models: 500 V opto-isolated input-to-power/output with isolated input enabled
- PD6730-APA: 500 V input/power-to-output
- PD6730-BTA: 500 V input-to-output
Connection
- Screw terminals accept 12 to 22 AWG wire
Communication
- Modbus RTU
- RS-485
Overall Dimensions (H x W x D)
- 5.67" x 5.25" x 4.18" (144 mm x 133 mm x 106 mm)
Weight
- 1.7 lbs (0.75 kg)