Images are representations only.

PD6938 VantageView+ NEMA 4X Pulse Input Flow Rate/Totalizer

Brand: Precision Digital Corporation
Does not ship to IL, United States
The Vantageview PD6730 is a plastic, field-mounted flow rate/totalizer that can display flow rate and total from a pulse output flowmeter. 

Its display has a five digit upper line for rate, a seven alpha-numeric character lower line for total, and comes standard with a backlight. 

The PD6730 is built in a NEMA 4X and IP65 rated plastic enclosure which can stand up to even the harshest environmental conditions. It can be powered from an included battery or a 24 VDC external power supply. 

Some features that really make the PD6730 stand out are its automatic unit conversions from flowmeter k-factor units, ability to log up to 1024 data points, and SafeTouch® through-window buttons. 

These buttons allow the PD6730 to be programmed and operated through the cover window, thus eliminating the need to remove the cover in dirty or wet environments.

Features

  • Pulse, Open Collector, NPN, PNP, TTL, Switch Contact, Sine Wave - Coil, Square Wave, Opto-Isolated Inputs
  • NEMA 4X, IP65 Plastic Enclosure for Safe Areas
  • 5-Digit 0.7" / 17.8 mm Top Display for Rate or Total
  • 7 Alphanumeric Character 0.4" / 10.2 mm Lower Display for Rate, Total, Grand Total, Units, and Tag
  • 13-Digit Totalizer with Total Overflow Feature
  • SafeTouch® Through-Window Button Programming
  • Isolated 4-20 mA Output for Rate, Total, or Grand Total
  • Two Isolated Open Collector Pulse Outputs, Up to 5 kHz
  • Battery, DC, or Output Loop-Powered Models
  • Gate Function for Rate Display of Slow Pulse Rates
  • K-Factor, Scaling, or Live Input Calibration with 32-Point Linearization
  • Automatic Rate, Total, and Grand Total Unit Conversions
  • Password Protection
  • Backlight Standard on All Models
  • On-Board Data Logging
  • Modbus® Communications RS-485 Option
  • Flanges for Wall or Pipe Mounting
  • Operates from -40 to 75°C
show more
The Vantageview PD6730 is a plastic, field-mounted flow rate/totalizer that can display flow rate and total from a pulse output flowmeter. 

Its display has a five digit upper line for rate, a seven alpha-numeric character lower line for total, and comes standard with a backlight. 

The PD6730 is built in a NEMA 4X and IP65 rated plastic enclosure which can stand up to even the harshest environmental conditions. It can be powered from an included battery or a 24 VDC external power supply. 

Some features that really make the PD6730 stand out are its automatic unit conversions from flowmeter k-factor units, ability to log up to 1024 data points, and SafeTouch® through-window buttons. 

These buttons allow the PD6730 to be programmed and operated through the cover window, thus eliminating the need to remove the cover in dirty or wet environments.

Features

  • Pulse, Open Collector, NPN, PNP, TTL, Switch Contact, Sine Wave - Coil, Square Wave, Opto-Isolated Inputs
  • NEMA 4X, IP65 Plastic Enclosure for Safe Areas
  • 5-Digit 0.7" / 17.8 mm Top Display for Rate or Total
  • 7 Alphanumeric Character 0.4" / 10.2 mm Lower Display for Rate, Total, Grand Total, Units, and Tag
  • 13-Digit Totalizer with Total Overflow Feature
  • SafeTouch® Through-Window Button Programming
  • Isolated 4-20 mA Output for Rate, Total, or Grand Total
  • Two Isolated Open Collector Pulse Outputs, Up to 5 kHz
  • Battery, DC, or Output Loop-Powered Models
  • Gate Function for Rate Display of Slow Pulse Rates
  • K-Factor, Scaling, or Live Input Calibration with 32-Point Linearization
  • Automatic Rate, Total, and Grand Total Unit Conversions
  • Password Protection
  • Backlight Standard on All Models
  • On-Board Data Logging
  • Modbus® Communications RS-485 Option
  • Flanges for Wall or Pipe Mounting
  • Operates from -40 to 75°C

Specifications

Display

  • Top: Five digits (0 to 99,999), 0.7" (17.8 mm) high, 7-segment, automatic lead zero blanking
  • Bottom: Seven alphanumeric characters, 0.4" (10.2 mm) high, 14-segment, automatic lead zero blanking
  • Symbols: Total, grand total, battery power/low battery, high alarm, low alarm, SafeTouch button sleep mode/disable, password lock

Display Update Rate

  • Ambient > -20°C: 1 Update/Second
  • Ambient < -20°C: 1 Update/10 Seconds

Programming Method

  • Four SafeTouch through-window buttons when cover is installed. Four internal pushbuttons when cover is removed. Free MeterView EX software

Enclosure

  • NEMA 4X, IP66 plastic field enclosure, polycarbonate with UV stabilizer
  • Color: grey
  • Window: Clear polycarbonate with UV stabilizer
  • Three 3/4" NPT threaded conduit openings
  • Two 3/4" NPT plastic conduit plugs included

Environmental

  • Relative Humidity: 0 to 90% non-condensing
  • Printed circuit boards are conformally coated
  • Operating/Storage: -40° to 75° C (-40° to 167° F)

Power Options

  • 9-30 VDC Powered, 2.2 W max
  • 4-20 mA Output Powered, 30 VDC max
  • Battery Power
  • 9-30 VDC Powered with Battery Backup
  • 4-20 mA Output Powered with Battery Backup

Mounting

  • May be mounted directly to conduit
  • Two slotted flanges for wall mounting or NPS 1-1/2" to 2-1/2" or DN 40 to 65 mm pipe mounting

Isolation

  • All models: 500 V opto-isolated input-to-power/output with isolated input enabled
  • PD6730-APA: 500 V input/power-to-output
  • PD6730-BTA: 500 V input-to-output

Connection

  • Screw terminals accept 12 to 22 AWG wire

Communication

  • Modbus RTU
  • RS-485

Overall Dimensions (H x W x D)

  • 5.67" x 5.25" x 4.18" (144 mm x 133 mm x 106 mm)

Weight

  • 1.7 lbs (0.75 kg)