Images are representations only.

MPX-F Level Sensor

Brand: Automation Products Group - APG
The MPX Series Magnetostrictive Level Sensor provides highly accurate and repeatable level readings in a wide variety of liquid level measurement applications. The MPX-F’s flexible stainless steel stem allows for accurate measurements in environments that are not straight-forward.
Features
  • Class 1 Division 1 Groups C & D, Class 1 Zone 1, Class 1 Zone 2
  • Highly accurate and repeatable readings
  • 4-20 mA, RS-485 (Modbus RTU) output
  • Rugged and reliable, lengths up to 32 feet (9.75 m)
  • Dual level (interface) measurement
  • Tank volume/level, strapping table
show more
The MPX Series Magnetostrictive Level Sensor provides highly accurate and repeatable level readings in a wide variety of liquid level measurement applications. The MPX-F’s flexible stainless steel stem allows for accurate measurements in environments that are not straight-forward.
Features
  • Class 1 Division 1 Groups C & D, Class 1 Zone 1, Class 1 Zone 2
  • Highly accurate and repeatable readings
  • 4-20 mA, RS-485 (Modbus RTU) output
  • Rugged and reliable, lengths up to 32 feet (9.75 m)
  • Dual level (interface) measurement
  • Tank volume/level, strapping table
MPX-F1-ML-P3SB-360
APG MPX Magnetostrictive Sensor, 1"Dia Flex Hose & Braid, 3" NPT Plug Mt, Slide, 316LSST, 360" View More
  • MPX: Explosion Proof and Non-Incendive Magnetostrictive Level Sensors
  • F: Stem Type: 7/8" Diameter, Flexible Tubing with Braid, 316L SS
  • 1: Single float, 4-20 mA (loop powered, 2 wire)
  • ML:
    • Top Float: M-Red Poly Float, 2W x 5.5H .57SG
    • Bottom Float: L-Blue Poly Float, 2W x 5.5H .94SG

  • P: NPT Plug 150#
  • 3: 3" NPT Mounting Size
  • S: Mounting Connection: Slide with Compression Fitting (adjustable)
  • B: 316L SST Stem Material
  • 360: Total Stem Length in Inches
  • Safety Rating:
    • Class I, Division 2, Groups C and D
    • Ex nA IIB
    • Class I, Zone 2; AEx nA IIB

3 - 5 weeks
$2,886.14USD
$19.01 Shipping

Specifications

Accuracy

  • ± 0.05 % of Span

Approvals & Certifications

  • CSA Class I, Div. 1, Groups C, D T4 (Ta 85° C) Class I, Zone 1, AEx d IIB T4 Class I, Zone 2, AEx NA IIB T4 Ex d IIB T4 Ex NA IIB T4

Communication

  • Interface with RS-485 Modbus RTU

Electrical Connectors

  • Terminal Block

Enclosure, Body Material

  • Die Cast Aluminum

Environmental Protection

  • IP65
  • NEMA 4X

Flange Size - 1” (DN 25)

  • 1” (DN 25) - 150#

Flange Size - 1-1/2” (DN 40)

  • 1-1/2” (DN 40) - 150#

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150#

Flange Size - 2-1/2” (DN 65)

  • 2-1/2” (DN 65) - 150#

Flange Size - 3” (DN 80)

  • 3” (DN 80) - 150#

Flange Size - 3-1/2” (DN 90)

  • 3-1/2” (DN 90) - 150#

Flange Size - 4” (DN 100)

  • 4” (DN 100) - 150#

Flange Size - 5” (DN 125)

  • 5” (DN 125) - 150#

Flange Size - 6” (DN 150)

  • 6” (DN 150) - 150#

NPT Connection

  • 1” NPT Male
  • 1-1/2” NPT Male
  • 2” NPT Male
  • 2-1/2” NPT Male
  • 3” NPT Male
  • 3-1/2” NPT Male
  • 4” NPT Male
  • 5” NPT Male
  • 6” NPT Male

Operating Temperature

  • -40° to 85° C (-40° to 185° F)

Operating Temperature - Electronics

  • -40° to 60° C (-40° to 140° F)

Output

  • 4-20 mA

Resolution

  • 0.04” (1 mm)

Sensor, Probe Style

  • Float

Supply Voltage

  • 12-24 Vdc

Tri-Clamp Connection

  • 1” Sanitary Clamp
  • 1-1/2” Sanitary Clamp
  • 2” Sanitary Clamp
  • 2-1/2” Sanitary Clamp
  • 3” Sanitary Clamp
  • 3-1/2” Sanitary Clamp
  • 4” Sanitary Clamp
  • 5” Sanitary Clamp
  • 6” Sanitary Clamp