Images are representations only.

CCS DUAL-SNAP Temperature Switch, Non-Haz. Area, 1/2" NPT 300 SST, 15` Capillary

Price
$2,606.16 USD
Stock
Lead Time: 13 - 14 weeks
Does not ship to IL, United States
Description
  • Adjustable Set Point Range:
    • Increasing: +35°F to +140°F, +2°C to +60°C
    • Decreasing: +21°F to +135°F, -6°C to +57°C
  • Deadband: Approximately
    • At Bottom of Range: 14°F, 4°C
    • At Top of Range: 5°F, 3°C
  • Probe Temperature (Maximum): +300°F, +149°C
  • Wetted Materials:
    • Temperature Probe: 300 Stainless Steel & Graphite
    • Capillary Tube: Lubricated Glass Fiber
  • Relay: SPDT
  • Contacts: Gold
  • UL, CE Mark, NACE, General Purpose
  • Adjustable Set Point Range:
    • Increasing: +35°F to +140°F, +2°C to +60°C
    • Decreasing: +21°F to +135°F, -6°C to +57°C
  • Deadband: Approximately
    • At Bottom of Range: 14°F, 4°C
    • At Top of Range: 5°F, 3°C
  • Probe Temperature (Maximum): +300°F, +149°C
  • Wetted Materials:
    • Temperature Probe: 300 Stainless Steel & Graphite
    • Capillary Tube: Lubricated Glass Fiber
  • Relay: SPDT
  • Contacts: Gold
  • UL, CE Mark, NACE, General Purpose

Specifications

NACE & NIST

  • NACE MR-0175: 2003

Operating Temperature

  • -40° to 86° C (-40° to 187° F)

Electrical Contacts

  • Silver
  • Gold

Deadband, Approximate - Bottom of Range

  • -13° to -4° C (9° to 25° F)
  • 4° to 13° C (39° to 55° F)

Standard Features

  • Internal Case Ground
  • Weatherproof

Environmental Protection

  • IP 65
  • IP 66
  • NEMA 4
  • NEMA 13

Process Connection

  • 1/2" NPT Male

Proof Pressure

  • bar: 103.4
  • kPa: 10,342
  • psig: 1,500

Maximum Sensor, Probe Temperature

  • 121° to 343° C (250° to 650° F)

Set Point Range - Increasing

  • -34° to 332° C
  • -34° to 332° C (-29° to 630° F)

O-Ring Material

  • None

Electrical Rating

  • 1 A at 125 Vac, 50/60 Hz
  • 15 A at 125/250/480 Vac Resistive, 0.4 A at 125 Vdc, 0.2 A at 250 Vdc
  • 5 A at 125/250 Vac Resistive, 5 A at 28 Vdc, 0.5 A at 125 Vdc

Switch Type

  • SPDT
  • DPDT

Capillary Length

  • 10 ft (3 m)
  • 15 ft
  • 25 ft
  • 5 ft (1.524 m)

Approvals & Certifications

  • CE
  • CRN - Canadian Registration Number
  • CRN - Alberta
  • CRN - British Columbia
  • CRN - Manitoba
  • CRN - N.W. Territories
  • CRN - Saskatchewan
  • CSA
  • cUL
  • EMC
  • LVD
  • PED
  • RoHS
  • UL

Sensor, Probe Material

  • Stainless Steel & Graphite

Deadband, Approximate - Top of Range

  • -16° to -14° C (3° to 6° F)
  • 2° to 8° C (36° to 46° F)

Enclosure, Body Material

  • Aluminum

Set Point Range - Decreasing

  • -39° to 329° C
  • -39° to 329° C (-38° to 624° F)

Capillary Material

  • Lubricated Glass Fiber

System Pressure

  • bar: 86
  • kPa: 8,618
  • psig: 1,250

Electrical Connectors

  • Terminal Strip - Internal

Adjustment Type

  • Field Adjustable

Area Classification

  • Non-Hazardous Area