Images are representations only.

CCS DUAL-SNAP Pressure Switch, Non-Haz. Area, 1/2" NPT SST Port & Diaphragm, Viton

Price
$381.68 USD
Stock
3 In Stock
Description
  • Adjustable Set Point Range
    • Increasing
      • psig   1800 - 3400
      • kPa    12,410.6 - 23,442.15
      • bar     124 - 234
    • Decreasing
      • psig   1520 - 3120
      • kPa    10,480.0 - 21,511.6
      • bar     105 - 215
  • Deadband - Approximate: 280 psi, 1930.5 kPa, 19.3 bar
  • System Pressure Maximum: 5000 psig, 34,473.75 kPa, 345 bar
  • Proof Pressure: 7500 psig, 51,710.63 kPa, 517 bar
  • Wetted Materials
    • Pressure Port: 1/2" FNPT 316 Stainless Steel
    • Diaphragm: 316 Stainless Steel
    • O-Ring: Viton
  • Relay: SPDT
  • CSA, CRN, CE Mark, NACE, NEMA
  • Adjustable Set Point Range
    • Increasing
      • psig   1800 - 3400
      • kPa    12,410.6 - 23,442.15
      • bar     124 - 234
    • Decreasing
      • psig   1520 - 3120
      • kPa    10,480.0 - 21,511.6
      • bar     105 - 215
  • Deadband - Approximate: 280 psi, 1930.5 kPa, 19.3 bar
  • System Pressure Maximum: 5000 psig, 34,473.75 kPa, 345 bar
  • Proof Pressure: 7500 psig, 51,710.63 kPa, 517 bar
  • Wetted Materials
    • Pressure Port: 1/2" FNPT 316 Stainless Steel
    • Diaphragm: 316 Stainless Steel
    • O-Ring: Viton
  • Relay: SPDT
  • CSA, CRN, CE Mark, NACE, NEMA

Specifications

Proof Pressure

  • bar: 51.7 to 310
  • kPa: 5,171 to 31,026
  • psig: 750 to 4,500

Standard Features

  • Weatherproof

Deadband, Approximate

  • bar: 0.14 to 19.3
  • kPa: 13.8 to 1,931
  • psi: 2 to 280

Set Point Range - Increasing

  • bar: 0.21 to 234
  • kPa: 20.7 to 23,442
  • psig: 3 to 3,400

Electrical Certification

  • CSA Listed by Canadian Standard Association (CSA) Testing Laboratories (File LR22665) for Enclosure (4) Non-hazardous Locations.

Electrical Connectors

  • 1/2" NPT Male
  • Electrical Connector with 4-Blades, Conforms to DIN-43650
  • Electrical Connector with Gold Contacts & Blades, Conforms to DIN-43650

Operating Temperature

  • -40° to 86° C (-40° to 187° F)

Set Point Range - Decreasing

  • bar: 0.07 to 215
  • kPa: 6.9 to 21,512
  • psig: 1 to 3,120

Service

  • Sour - Oil & Gas

Electrical Rating

  • 1 A at 125 Vac, 50/60 Hz
  • 11 A at 125/250 Vac

System Pressure

  • bar: 34.5 to 207
  • kPa: 3,447 to 20,684
  • psig: 500 to 3,000

Area Classification

  • Non-Hazardous Area