Images are representations only.

CCS DUAL-SNAP Pressure Switch, Hazardous Area

Price
Request a Quote
Stock
Lead Time: 24 - 25 weeks
Description
  • Set Point Range: Increase by 2 psig, Decrease 1 + 0.25 psig
  • Proof Pressure: 125 psig
  • Electrical Rating: 15A 125/250/480 VAC; 0.4A 125 VDC
  • Set Point Range: Increase by 2 psig, Decrease 1 + 0.25 psig
  • Proof Pressure: 125 psig
  • Electrical Rating: 15A 125/250/480 VAC; 0.4A 125 VDC

Specifications

Electrical Certification

  • cUL, UL/CSA, Hazardous Areas, Div. 1, 2

Electrical Connectors

  • 1/2" NPT Male

Proof Pressure

  • bar: 17.24
  • kPa: 1,724
  • psig: 250

Service

  • Sweet - Oil & Gas

Deadband, Approximate - Bottom of Range

  • bar: 0.03 to 0.096
  • kPa: 3.5 to 9.6
  • psi: 0.5 to 1.4

Operating Temperature

  • -40° to 86° C (-40° to 187° F)

Deadband, Approximate - Top of Range

  • bar: 0.069 to 0.55
  • kPa: 6.9 to 55.1
  • psi: 1 to 8

Set Point Range - Decreasing

  • bar: 0.07 to 4.96
  • kPa: 6.9 to 496.4
  • psig: 1 to 72

Set Point Range - Increasing

  • bar: 0.103 to 5.52
  • kPa: 10.4 to 551.5
  • psig: 1.5 to 80

Electrical Assembly

  • Hermetic Seal

System Pressure

  • bar: 11.03
  • kPa: 1,103
  • psig: 160

Electrical Rating

  • 1 A at 125 Vac, 1 A at 30 Vdc
  • 15 A at 125/250/480 Vac Resistive, 0.5 A at 125 Vdc, 0.2 A at 250 Vdc
  • 5 A at 125/250 Vac Resistive, 5 A at 28 Vdc, 0.5 A at 125 Vdc

Area Classification

  • Hazardous Area